110V 10A Panasonic motor driver development

Поділитися
Вставка
  • Опубліковано 5 січ 2025

КОМЕНТАРІ • 5

  • @jimhong9575
    @jimhong9575 2 роки тому +1

    hello, could I ask how you get the encoder data from Panasonic motor?
    Because Panasonic didn't seems to publishing the protocol🥺.

    • @jimhong9575
      @jimhong9575 2 роки тому

      @@inthz thx

    • @jimhong9575
      @jimhong9575 2 роки тому

      @@inthz Hi, I sent 0x2A to the encoder but I didn’t receive data.
      I also tried the address from 0x00 to 0xFF and found it response with 0xA2, 0xAA, 0xDA and 0xF2.
      But, when I sent 0xDA, I received 68 bits formatted like this
      [8bit] [28bit] [8bit]
      [0xDA] [encoder?] [unknown]
      Other bits aren’t data include start bit, stop bit and wait.
      Other addresses are in similar format.
      Is this format T-format, A-format or something others?
      My motor is Panasonic MSMF021L1S2 with 23bit absolute encoder.

    • @jimhong9575
      @jimhong9575 2 роки тому +1

      # I confirm the 28 bit data is encoder counts without encrypted, because the value is increasing / decreasing when I turn the motor shaft.
      thx.

  • @jeonjinkang1281
    @jeonjinkang1281 2 роки тому +1

    멋지네요 수석님!