Bahot shukriya bro ALLAH Pak Apko hamisha khosh aur abaAd rakhay AmEen Jnab aik Ats 400 Amp se 2 GENERATORS kistarha conict kiye jate hai keh aik generator main koi problem hojaye to dosra GENERATOR automatically start hojaye
G brother ap ek Ats ke Sath ek generator he link ker sekty hain, agr ap ke do Generator hain or un me se koi ek chlta he to Ats se pehly dono generators main ek manual change over lga leyn
Dono generator ap ke auro start hony chahyn , Jo generator ap auto connect kerna chahty hain us ka controller auto mode per ker deyn our us ka power breakar on ker dayn ,or jes ko auto mode per nahi rekhna chahty us ko module se b off ker dayn or us ka power breakar b off ker dayn, dono generators ke power cables ATS me ek he contactor per lgti hain
Sir please tell me generator par incandecent lamp aur led bulb mein little bit flickering kyu feel hoti hai ?? Same wahi bul electricity supply par achhe se kam karta hai aur flickering nahi hota hai
Aap ne f1 Aur f2 pe exciter Ka wire connect Kiya N Aur L pe app ne test lamp Ka wire connect Kiya too phir 230 power supply kidhar connect Hoga please batan
Salam brother I need some more explanation because I am visually impaired person just tell me AVR has two side one side has four wires and other side has two wires where should we put 220 connection please explain colour of the wires too
@@rakeshsuthar2135 bro voltage problem he koi, ab detail ka pta chly to phir he Kuch pt chal sekta he , jesa kh generator Kon sa he? Controller Kon sa lga he
@@zainpakistan1797 ap ny card pr supply sahee lgani he AVR se related electronic markeet se kit bhe mel jati he jo avr ke sath permanent lg jati he push buton ke sath , AVR ko excite krwane ke ley
@@hafizkhurseed8047 assalam walekum Janab bhai mere pass 6.5 k ilowatt silent generator hai Uske wiring mistake I sar wiring kaise karen bhaijaan batao thoda
Bahot shukriya bro ALLAH Pak Apko hamisha khosh aur abaAd rakhay AmEen
Jnab aik Ats 400 Amp se 2 GENERATORS kistarha conict kiye jate hai keh aik generator main koi problem hojaye to dosra GENERATOR automatically start hojaye
G brother ap ek Ats ke Sath ek generator he link ker sekty hain, agr ap ke do Generator hain or un me se koi ek chlta he to Ats se pehly dono generators main ek manual change over lga leyn
Dono generator ap ke auro start hony chahyn , Jo generator ap auto connect kerna chahty hain us ka controller auto mode per ker deyn our us ka power breakar on ker dayn ,or jes ko auto mode per nahi rekhna chahty us ko module se b off ker dayn or us ka power breakar b off ker dayn, dono generators ke power cables ATS me ek he contactor per lgti hain
Thanks for knowgable video sharing.
Bohat shukriya bhai ik request he ap se, is avr ki fault finding video bna den such as component test(on board) or hot test.
Bhai yeh 3kva brush wale genset men lag sakta hai? Agr han to yeh kahan se milega?
Bina bulb lagaye sirf meter se check nhi kr sakte kya
Sir please tell me generator par incandecent lamp aur led bulb mein little bit flickering kyu feel hoti hai
?? Same wahi bul electricity supply par achhe se kam karta hai aur flickering nahi hota hai
Well explained 👌
thanks bro
Nice information
Brother main is same AVR ko 220 volt dyta hu to Fuse ur jata ha ya serious per on ho jata ha
Bro es ko 220 v per stand kerna cahy, serf serious per on nahi hona cahey, AVR khrab ho ga
Are vai a jo ligjt jol ne ke somoy kamp rohe he is ka ilaj keya hota hai ? please bataie a
بھائی صاحب اگر یہ لگائیں تو بریج لگانے کی پھر بھی ضروت ہوگی یا کام چل جائے گا
avr ya brig dono me koi ek lgya jata he
3phase Ka avr check Karne Ka tarika per vedio banaaiye
Bhai kirlosker 15 kva altinator ka AVR repair ho skta hai kya
Bro agr open kit he to ho sekta he
@@Generatorsprofessional pack hai KAVR h4 Modal
Bulb kitna watt ka lena hai
Aap ne f1 Aur f2 pe exciter Ka wire connect Kiya N Aur L pe app ne test lamp Ka wire connect Kiya too phir 230 power supply kidhar connect Hoga please batan
bro, AVR test ke doran hm ne f1 or f2 per light or l or n per 220 volt supply
ye L or N 220 v ke supply he he
Salam brother I need some more explanation because I am visually impaired person just tell me AVR has two side one side has four wires and other side has two wires where should we put 220 connection please explain colour of the wires too
Aut put me keya DC volt hote shokriya
G
Sir kindly bulb konsa use kre Dc or ac
@@irshadnaik6268 normal AC bulb
Walteg up don na kara to kya kharab ho sakta ha
Avr DC Volt reduction is not a problem. Sir, please tell me a little
AC ka bulb
DC pe kese On ho gya and dimming b ho rai ha
Ho jata he
Alt voltage lost alarm aa raha h DG set me plz reply solution
@@rakeshsuthar2135 bro voltage problem he koi, ab detail ka pta chly to phir he Kuch pt chal sekta he , jesa kh generator Kon sa he? Controller Kon sa lga he
Kirloskar 40 KVA DG SET controller KG 465
KG645 CONTROLLER H
jese hi 220 deta hon fuse blast ho jata hai bro.... reason?
Out put me kitna dc voltage ana padeka correct 230 ac voltage milne ke liye
90-100 volts
Asslamualaikum bulb ac or dc btaye
Ye bulb ac he ap ap ac or DC dono bulb testing ke ley estamal ker sekty hain
Bulb AC hai ya Dc
Bulb ac dc dono me kaam karega...heating effect dono hi denge...
Sir bulb ac tha ya dc
AC
Ac 100 watt ka
@@Generatorsprofessional sir ji poora jawab de 100 watt ka normal ac bulb
@@zainpakistan1797 100 watt normal ac bulb
@@Generatorsprofessional sir apki rehaish ap avr per kam karsaktay hain j
Open Circuit AVR kaha sy mil sakta hy?
Nice
Ac input 220 to DC mai kitna aana chahiye 25 kva 3 phase
Output veriable se control Hoti he ap apni merzi se km ya zeyada kr sekty hain
Aapne ye to nhi btaya ki ye avr think he ya nhi
The DC output voltage cannot be reduced. What could be the problem?
Use the transformer
Sir ji carbon k minus plus kisay maloom kar k avr per 12 volt ka jhatka de?
ap ne 12 volt AVR ke negative or positive ke output ke mtabik he apply krna hote hain, AVR ke negative pr negitive or positive pr positive
@@Generatorsprofessional ji ha maloom he lekin carbon k k minus plys ulat howay to card bach jayega
@@zainpakistan1797 ap ny card pr supply sahee lgani he AVR se related electronic markeet se kit bhe mel jati he jo avr ke sath permanent lg jati he push buton ke sath , AVR ko excite krwane ke ley
@@zainpakistan1797 ap 12 volt ka jhtka avr ke bjay main stator ke nutrial or phase pr lga leya kren
@@Generatorsprofessional ji lgaya tha spark howa armature rotar m jha carbon b slip ring lgi howie he
Ap ki worksop kaha hi
7kv core ka ganreter hai us ka speed bar jata hai
सिंगल फेस ए वी आर की कीमत क्या है
Aksaetar.rotar.ka vaendeg.palas.ka naksan.btay.peleg
वालेकुम अस्सलाम भाई आपके कांटेक्ट नंबर
kti hai.
avr shat hone par kya kami hosa
@@hafizkhurseed8047 assalam walekum Janab bhai mere pass 6.5 k ilowatt silent generator hai Uske wiring mistake I sar wiring kaise karen bhaijaan batao thoda
Good