I have planned to construct two separate rooms like 20*10 ( ground floor with 10*14 room size at first floor) & 22.5*10 (only ground floor) . My engineer suggested RCC is as follows. Pls tell it correct or not. Basement level of 22.5*10 is 2 feet less than 20*10 room 1. For 20*10 - 6 columns of 12*4 with 8mm stirr up of 7 inch c/c - four at each corner and remaining two at spacing of 8 feet at one end and 11 ft at other end. Plinth beam with 1.5 feet height and 9*9 (l*b). Ceiling height is 10 feet. Planned tie beam at below windows (2.5 feet) and lintel (7 feet) of 6 inch rcc 2. For 22.5*10 - 6 columns of 12*4 with 8mm stirr up of 7 inch c/c - four at each corner and remaining two at spacing of 10 feet at one end and 10 ft at other end. Plinth beam with 1 feet height and 9*9 (l*b). Ceiling height is 12 feet. Planned tie beam at below windows (4 feet) and lintel ( 8 feet) with 6 inch rcc And join the both room in ceiling and both room in 90 degree position to each other
காலத்திற்கு இடேவெளிக்கேற்ப எத்தனை 12 டையா கம்பி போட னும் என்று யாரும் சரியா சொல் வதில்லை. ஒரு அடி அகல கால முக்கு 11 அடி இடைவெளிக்கு எத்தனை 12 டையா கம்பி போட வேண்டும் ? சொல்லுங்கள் .
Distance between 2 column 9" * 9" 5 meter bro correcta sollunga mistake sari pannunga ok
I have planned to construct two separate rooms like 20*10 ( ground floor with 10*14 room size at first floor) & 22.5*10 (only ground floor) . My engineer suggested RCC is as follows. Pls tell it correct or not. Basement level of 22.5*10 is 2 feet less than 20*10 room
1. For 20*10 - 6 columns of 12*4 with 8mm stirr up of 7 inch c/c - four at each corner and remaining two at spacing of 8 feet at one end and 11 ft at other end. Plinth beam with 1.5 feet height and 9*9 (l*b). Ceiling height is 10 feet. Planned tie beam at below windows (2.5 feet) and lintel (7 feet) of 6 inch rcc
2. For 22.5*10 - 6 columns of 12*4 with 8mm stirr up of 7 inch c/c - four at each corner and remaining two at spacing of 10 feet at one end and 10 ft at other end. Plinth beam with 1 feet height and 9*9 (l*b). Ceiling height is 12 feet. Planned tie beam at below windows (4 feet) and lintel ( 8 feet) with 6 inch rcc
And join the both room in ceiling and both room in 90 degree position to each other
Thanks bro...it's very useflable
தம்பி நீங்கள் எந்த ஊர்??நாங்க வீடு கட்டலானு இருக்கோம் நல்ல முறையில் நீங்கள் சொல்கிறீர்கள் சூப்பர் நான் திருப்பூர் மாவட்டம்
Good explaination....
Make more vedios about column like 9"
Nice bro. Column , footing marking eppadi panrathu clear ah Podunga bro . Thank you for your updating videos
அதிக பட்ச இடைவெளி 5 metre span என்பது 9"*9" column த்திற்கா?
Aac block use pannlma
ஐந்து அடியா மீட்டரா பேன் கூறவும்
Maximum span length 5 Feet or 5 Meter...??
5 meter
@@HarishKumar-wb5zj kk...👍
All videos are very useful, Sir best of Luck
Bro column span upto 5 meter not feet
maximum span distance is 5 meter not 5 feet
இரு பில்லர்களுக்குமத்தியில் 5மீட்டர்(161/4)இருக்கலாம்.
voice puriyeve illa anna music sound mattum than kekuthu
5 meter nu write panetu 5 feet nu soluriga bro Max 10 feet
Maximum 16.40 feet
சரியான விளக்கம் இல்லை வேஸ்ட்
Yo background 🎶music romba disturbing un voice aa kekala
Eluthi vacchikittu padikkireengala sir theliva pesunga
காலத்திற்கு இடேவெளிக்கேற்ப எத்தனை 12 டையா கம்பி போட னும் என்று யாரும் சரியா சொல் வதில்லை. ஒரு அடி அகல கால முக்கு 11 அடி இடைவெளிக்கு எத்தனை 12 டையா கம்பி போட வேண்டும் ? சொல்லுங்கள் .
5 feet illa bro 5 mtr
Music upload pannama pesunga onnume puriyala vedio waste aittu
5 adi na 5 meter illa
தப்பு தப்பா சொல்லுறிங்க பிரதர்
Worst communication