Relay Working Principle & Types.

Поділитися
Вставка
  • Опубліковано 9 жов 2024
  • A relay is an electrically operated switch. It consists of a set of input terminals for a single or multiple control signals, and a set of operating contact terminals. The switch may have any number of contacts in multiple contact forms, such as make contacts, break contacts, or combinations thereof.
    Relays are used where it is necessary to control a circuit by an independent low-power signal, or where several circuits must be controlled by one signal. Relays were first used in long-distance telegraph circuits as signal repeaters: they refresh the signal coming in from one circuit by transmitting it on another circuit. Relays were used extensively in telephone exchanges and early computers to perform logical operations.
    SPST-NO (Single-Pole Single-Throw, Normally-Open) relays have a single Form A contact or make contact. These have two terminals which can be connected or disconnected. Including two for the coil, such a relay has four terminals in total.
    SPST-NC (Single-Pole Single-Throw, Normally-Closed) relays have a single Form B or break contact. As with an SPST-NO relay, such a relay has four terminals in total.
    SPDT (Single-Pole Double-Throw) relays have a single set of Form C, break before make or transfer contacts. That is, a common terminal connects to either of two others, never connecting to both at the same time. Including two for the coil, such a relay has a total of five terminals.
    DPST - Double-Pole Single-Throw relays are equivalent to a pair of SPST switches or relays actuated by a single coil. Including two for the coil, such a relay has a total of six terminals. The poles may be Form A or Form B (or one of each; the designations NO and NC should be used to resolve the ambiguity).
    DPDT - Double-Pole Double-Throw relays have two sets of Form C contacts. These are equivalent to two SPDT switches or relays actuated by a single coil. Such a relay has eight terminals, including the coil.
    For PLC Basic click : • PLC Basic with ladder ...
    For Star-Delta Starter click : • Star Delta Starter Pow...
    #Relay #Relaybasic #Relayworking #technicalstudy #SPST #SPDT #DPST #DPDT #RELAY #beginners #Power #Control, , #Starter, #Motor, #PowerCircuit, #ControlCircuit, #Ckt, #Overload, #Electrical, #Electonic, #InterviewQuestions, #TechnicalStudy, #Diploma, #Btech, #ITI, #Motorstartingprocess, #Motor, #Start,#Run, #3PhMotor, #1phmotor, #Deltastarstarterconnection, #Technician, #Engineer, #Supervisor, #Industrialquestions, #MotorConnection, #Connection. #Interviews, #Differentbetweenstardelta, #Different, #Connection, #TechnicalInterviews, #ElectricalQuestions #DOLStarter, #Power, #Control, #DOL, #Starter, #Motor, #DirectonlineStarter, #PowerCircuit, #ControlCircuit, #Ckt, #Overload, #Electrical, #Electonic, #InterviewQuestions, #TechnicalStudy, #Diploma, #Btech, #ITI, #Motorstartingprocess, #Motor, #Start,#Run, #3PhMotor, #1phmotor, #DirectOnlineStarter, #Technician, #Engineer, #Supervisor, #Industrialquestions, #MotorConnection, #Connection.

КОМЕНТАРІ • 4

  • @chandrakanthedalkar1078
    @chandrakanthedalkar1078 3 роки тому

    सर आप बहुत अच्छे तरहसे बताते हो.
    धन्यवाद

  • @manjaljeet8686
    @manjaljeet8686 3 роки тому

    thanks

  • @venkatadriadusumilli4389
    @venkatadriadusumilli4389 3 роки тому

    One boiler and water pump okay
    Water level low than Stop to heaters control and start to water pump .
    Water level is okay then pump control stop and boiler control is starting this is the system.