Manifold Gas Pressure

Поділитися
Вставка
  • Опубліковано 7 вер 2024

КОМЕНТАРІ • 42

  • @walterschumaker9567
    @walterschumaker9567 Рік тому +1

    This morning, this is the best explanation available on UA-cam in my humble opinion. Thank you

  • @SiteReader
    @SiteReader Рік тому +1

    He gets right to the point and gives you all the information you need, straight up with no BS. I wasted an hour watching two other ones that didn't show half what he shows.

  • @KavinSBS
    @KavinSBS 3 роки тому +2

    the best video I have ever seen about explaining the gas valve and how to adjust it,

  • @petergilbert144
    @petergilbert144 5 років тому +4

    As always great job Bill. I am in my 4th class with him and he not only can teach and lay a ton of information on you, but make a long class fun, exciting, and a place you look forward to being in. This is the kind of guy you want as your technician that has more brains than a much senior tech.
    Edit: today I become an alumni of the program.

  • @freddesjardins7399
    @freddesjardins7399 11 місяців тому

    Excellent instructions complete and very concise from a to z 👍

  • @aundraydavid4821
    @aundraydavid4821 3 роки тому +4

    Almost 4 years I've been outta school bill, still helping me out! Miss being in the Roc

  • @henripedro4760
    @henripedro4760 5 років тому +2

    Excellent informative video. The man really presented the information in a very professional way. Thank you.

  • @Feather-Frame
    @Feather-Frame 5 років тому +1

    Very informative video. I learned a lot. Surprised this video is this old with only a couple comments!

  • @kevincopley7783
    @kevincopley7783 Рік тому

    Thank you so much for this video. You’ve saved me a ton of headaches!

  • @jefferydickinson3129
    @jefferydickinson3129 3 роки тому +1

    Very good video great presentation

  • @DONALD1951
    @DONALD1951 5 років тому

    Gas companies are also responsible for the meter. Homeowner is responsible for everything after the meter outlet. Some services don’t have a regulator. If it is a low pressure service.
    Very good video.

  • @chrismaddox15
    @chrismaddox15 4 роки тому +1

    Great info..... thanks for such a great video!

  • @rasheed4585
    @rasheed4585 4 роки тому +1

    Explained professionally

  • @bigd835
    @bigd835 4 роки тому

    Fantastic video. Took all the voodoo out of the furnace set up. Thank you !!

  • @tbi1161
    @tbi1161 Рік тому

    Well done teaching, thank you

  • @sirvayr
    @sirvayr 4 роки тому

    I was wondering about this. Saved me money on buying a digital fofr something I will never use again.

  • @miguelmorales6148
    @miguelmorales6148 3 роки тому

    Very good video, so professional good explanations

  • @tgamirov
    @tgamirov 2 роки тому

    Excellent video, thanks

  • @billrimmer5596
    @billrimmer5596 4 роки тому

    Excellent job!!

  • @donnierobertson3088
    @donnierobertson3088 3 роки тому

    Great job and video like always

  • @daveo.5479
    @daveo.5479 3 роки тому

    great video!

  • @KavinSBS
    @KavinSBS 3 роки тому

    The best way to explain

  • @justincomer7302
    @justincomer7302 4 роки тому +1

    That’s a very basic way to set gas pressure. That 3.5 rating on the furnace is in perfect conditions at an exact altitude with the exact size orfice.. Just because you set a furnace at 3.5” WC does not mean you getting a safe combustion or complete combustion. A combustion analyzer is the only proper way to determine your getting the correct fuel to air ratio. Adjusting the gas pressure up or down while watching the combustion readings to make sure your at the right oxygen and CO content within the furnace. So you may end up with 3.2” or 3.8” and orfices may need to be replaced to achieve this. So if your adjusting gas pressure with out doing a combustion analysis then your just guessing and could be leaving an unsafe condition.

    • @brianmutascio8325
      @brianmutascio8325 4 роки тому +1

      Why is it, that equipment mfg don't supply the O2 & CO content on the furnace spec data plate, along with the "W.C data....

    • @boby115
      @boby115 3 роки тому +5

      @@brianmutascio8325 , you are correct. The manufacturer's info plate will supply you with minimum and maximum Inlet pressures, specific manifold pressure & temperature rise ranges. Oxygen, CO2, CO and moisture content can be analyzed. Analyzing the products of combustion is a good practice, so we can verify the unit is in range but using it to adjust gas pressure and determining the fixed orifice sizes should be left to the OEM not the installer. Just an FYI, a lot of things can affect combustion analyzation ( quality of gas, combustion air quality, humidity , Venturi adjustment, gas pressure and yes improper orifice sizing, but someone would have to make a mistake for that to happen). Anytime a gas Appliance is put into service, always follow manufacturers instructions,GAMA ( Gas Appliance Manufacturers Association) requirements & the National Gas Fuel Codes. Hope some of this helps and you all please stay safe out there.

  • @luisvillegas4412
    @luisvillegas4412 3 роки тому

    Very good vidio 👋

  • @christopherpaul2938
    @christopherpaul2938 4 роки тому

    great video

  • @CVDUSA
    @CVDUSA Рік тому

    very good

  • @williambuck5652
    @williambuck5652 6 років тому

    YOUR VIDEO IS VERY GOOD!!!

  • @bobbyz7736
    @bobbyz7736 2 роки тому

    The furnace shown in the example shows a union before the gas valve. Shouldn't the union be placed after the gas valve?

  • @mikefox2379
    @mikefox2379 2 роки тому

    I checked pressures on a the newer valve with the small allen key screws. I actually removed the screw and put it back as tight as it was (to the best of my knowledge) Is this going to cause an issue? I just heard you say to NOT remove the screw and just turn it a full turn.

  • @stevebockiaro3832
    @stevebockiaro3832 2 роки тому +1

    How do you adjust the inlet gas to the valve if it’s to low or high?

    • @eegg6954
      @eegg6954 Рік тому

      On a high pressure service, the outside pressure regulator can be adjusted, but this is the job of the utility. On a low pressure service, the utility should be contacted after you have checked the sizing and loss of your supply piping run for your connected load.

  • @c_farther5208
    @c_farther5208 5 років тому

    I used to go to that college, smart people there. Anyway, is there a reason I get a high pitched squeal when it is running? Seems like it only does that when it is super cold outside.

  • @enzoamore9173
    @enzoamore9173 4 роки тому

    What causes condensation in flue pipe on natural gas boiler?

  • @hkhalil718
    @hkhalil718 3 роки тому

    what size of the fitting ? you said 1/4 in, right?

  • @enzoamore9173
    @enzoamore9173 4 роки тому

    The barb fitting only goes on hand tight when taking manifold gas pressure?

  • @lancerudy9934
    @lancerudy9934 4 роки тому

    What would happen if you lowered the gas pressure to the out put side of regulator.?

    • @eegg6954
      @eegg6954 Рік тому

      The flame lowers and the boiler is down fired, putting out less heating BTU... The mixture air/fuel ratio may also be affected and should be adjusted using the proper analyzer if desired. The firing rate should not be modified unless approved by the burner manufacturer.

  • @vicmazza1756
    @vicmazza1756 Рік тому

    No look at actual meter ... Plus and minus ports on meter ...using the meter??????

  • @jaykemm3472
    @jaykemm3472 2 роки тому

    Would be much better with the shirt off.