Comparing Tektronix 2465B and 2467B oscilloscopes

Поділитися
Вставка
  • Опубліковано 28 лис 2024

КОМЕНТАРІ • 19

  • @carriersignal
    @carriersignal 7 років тому +2

    Jim Williams is a legend. Good to see his efforts and ideas still being put to use.

  • @0x637A30
    @0x637A30 9 років тому +2

    I have a Tek 2467B in a perfect "like new" condition with under 2000 hours worktime. And this scope is simply wonderful. It is more a bellyful piece of art then a scope, actually.

  • @JohnFHendry
    @JohnFHendry 9 років тому

    Excellent... just what I wanted to see. Huge difference.

  • @ovalwingnut
    @ovalwingnut 5 років тому

    SUBSCRIBED. You invoked JW's memory 😊

  • @ngovietduy
    @ngovietduy 2 роки тому

    works and looks wonderful

  • @SoddingaboutSi
    @SoddingaboutSi 7 років тому

    Impressive scope.

  • @volcanowb
    @volcanowb 5 років тому

    Cool video. What pf scope lead are you using?

  • @jhallenworld
    @jhallenworld 4 роки тому

    I have the 1 GHz microchannel plate CRT 7104, but it's a beast compared with the 2467B. I almost always use my 485 instead. Is the 2467B heavy?

  • @volcanowb
    @volcanowb 6 років тому

    Great information!
    I thought the 2467x has a timeout?

    • @nezbrun872
      @nezbrun872  6 років тому

      It does, it resets after each front panel adjustment to increase CRT life. The length of the timeout varies depending on trace intensity from about one to four minutes or so. I don't know how it can be adjusted or disabled. It can be a bit irritating at times!

  • @noname-style
    @noname-style 3 роки тому

    What probes can i get for this scope (what are you using on your videom) other than the stock P6137?

    • @nezbrun872
      @nezbrun872  3 роки тому +1

      I bought them in Akihabara, Texas TX6250R akizukidenshi.com/catalog/g/gM-08001/
      akizukidenshi.com/download/ds/hongkongtexas/500MHz_Probe.pdf
      akizukidenshi.com/download/ds/hongkongtexas/TX62xxR.pdf

  • @zeljkoadzic1692
    @zeljkoadzic1692 4 роки тому

    Hi Sir I get 2465B from my dear friend ho died from cancer few month before... i have problem with oscilloscope and for legacy and memory i wont repair.. can you help me to fine manual and anther stuff... best regards..

  • @elipticolt17
    @elipticolt17 7 років тому

    Hi I have Tek 2456b and either I don't know to use this function or it does not work could you please give a demo on using this function on a 2456b Cheer's

    • @nezbrun872
      @nezbrun872  7 років тому

      Hello Robert, thank you for your comment. Which function(s) are you interested in? Delayed/dual trigger, dual timebase, or something else?

    • @elipticolt17
      @elipticolt17 7 років тому

      Okay I may be wrong but my understanding of the SGL SEQ function is to capture a single scan cycle so you can view it on the CRT .Now I
      can arm the trigger and the READY light is displayed I then trigger it by applying a pulse. The screen flashes and if you watch the crt carefully you can see it captures the scan the ready light goes off .
      At this point the screen is blank and remains blank.
      I have been through the manual and performed all test it passes all test.
      Am I wrong in assuming the data should be displayed ?
      If so what is the purpose of this
      I need to capture the very start of a pulse sequence
      The manual says the data is displayed after all scans have been triggered and the screen display's the data for photography purposes.
      Cheer's thanks for the reply.