Honeywell HVAC thermostat DIY install hack job butcher re-wire

Поділитися
Вставка
  • Опубліковано 14 жов 2024

КОМЕНТАРІ • 194

  • @aaronkirleis659
    @aaronkirleis659 8 місяців тому +2

    Great hands on video! Great terminology of old school wire color usage and current color codes!

  • @daved3021
    @daved3021 2 роки тому +5

    It was nice to see you taking the time to seal-off the wall opening for the thermostat wires to temper inner wall air movement that might adulterate the performance of the thermistor. Also, I have the Honeywell RTH9585WF1004 and the .5 degree temp swing is murder on my heat pump with 5 minutes between cycles. Bought a LuxPro to replace it with adj swing. Thank you for all your insight!!!

  • @williammarik6159
    @williammarik6159 3 роки тому +4

    Ted. I was paid for a job today with crisp $100-bills. Then i recieved a call from a renovation house sounding like a dirty Flame sensor. I will be there tomorrow and will use one of the hundies to clean said sensor. I will report back to you with the results. Thx.

  • @viralvideos6532
    @viralvideos6532 3 роки тому +8

    When I mount thermostats, especially new wire thermostat installations, I always try to tuck the access wire into the wall, and preserve it. I still wire everything neat, there isn't a nest of wires in the thermostat, but in several years, when a new thermostat needs to be installed, theres an extra 3-4 inches in the wall. You're welcome.

  • @jefferygrady3181
    @jefferygrady3181 3 роки тому +6

    What a mess you had there and a good opportunity to install the right new equipment! You will have another customer for life TED!

  • @TheBurnsStuff
    @TheBurnsStuff 3 роки тому +41

    That touchscreen would have a hammer through it being that slow.

    • @James_Bowie
      @James_Bowie 3 роки тому +2

      It's the Molasses model.

    • @michaelbarbone9310
      @michaelbarbone9310 3 роки тому +2

      Yes! It was driving me crazy just watching it.

    • @Knight805
      @Knight805 3 роки тому +2

      I think he was touching the wrong spot. Daikin iTouch does that sometimes. Gotta hit the sweet spot. If that don’t work, use hammer!

  • @DaddyBeanDaddyBean
    @DaddyBeanDaddyBean 3 роки тому +5

    I had a company replace my thermostats with programmable ones while they were replacing my boiler (HW baseboard). I eventually found they had wired the thermostats correctly, but had not set them up correctly at all - there are settings to take away the cooling mode (no central air) and settings specific to hydronic heating, presumably since temperature swings are slower than with forced air. I set it up correctly and the house was much more comfortable.

  • @eggman9713
    @eggman9713 3 роки тому +12

    That thermostat is the new version of the "Wifi 9000". I have the 1st gen version and like it. The touchscreen is not capacitive like a cellphone, it's an older style resistive touchscreen so you need to be very "deliberate" about what you press and how hard. Looks like a good de-hacking job!

  • @southernrrman
    @southernrrman 3 роки тому +9

    Customer is so lucky you knew the old wiring colors. Nice job.

  • @549BR
    @549BR 3 роки тому +4

    It was in the middle sixties in mid Florida, so I would think that you were at least ten or more degrees less inSC. Nice diagnosis and repair as usual.

  • @depluribusunum3128
    @depluribusunum3128 3 роки тому +2

    Evidently the first "tech" just did enough to get cooling going. Didn't need heat yet. I replaced the thermostats at my church with Honeywell wifi models. It reduced heating and cooling costs by 40%. By the way I retired from Trane as a Manufacturing technician for 32 years. I designed and built run test equipment for both split systems and package units.

    • @wskripka1
      @wskripka1 2 роки тому

      How does a thermostat reduce cost by 40 % ?

  • @Jon-hx7pe
    @Jon-hx7pe 3 роки тому +5

    heatpumps are great and super efficient aside from the aux heat use/capacity loss in cold weather - if you put in gas i hope it's dual fuel, keep the heatpump for mild weather.

  • @OfficialNakatsuMegami
    @OfficialNakatsuMegami 3 роки тому +3

    Love the video. You are really taking care of that customer. I always love happy endings and looking forward to the next video on this home.

  • @andrewbello983
    @andrewbello983 3 роки тому +3

    Somebody probably got confused when they changed outdoor unit. Rheem energizes RV in heat while all other manufactures energize the RV in cooling. Also the Rheem air handlers use purple and brown for 2nd stage heat and W/W1 can confuse you if you dont follow the schematic, which isnt always readable on old units so you may have to trace the wires!

  • @SeanBaker
    @SeanBaker 3 роки тому +9

    You cleaned up those wires real nice. That was a mess! That touchscreen was annoying.

    • @markgriz
      @markgriz 3 роки тому +1

      What's the point of a "touchscreen" if you have to touch it 10 times. What a piece of junk

  • @terryj-londonontariocanada4605
    @terryj-londonontariocanada4605 3 роки тому +2

    Always great to watch a master plying his craft, your methodology in diagnosing and repairing the fault efficiently are what earned you praise and trust from the home owner and most likely more work and future referrals, that is what it’s all about.

  • @sabergermd
    @sabergermd 3 роки тому +2

    Where I live it costs $150 just to have someone do a diagnosis. Any repair is extra. The mark up on parts is ridiculous. A $100 Taco zone circulator pump installed is $700 with the diagnostic fee. Ever since then I keep a supply of spare parts and I only call someone if I can't fix it. The next time a pump went, I have 5, it cost me $100 for the pump and a couple of bolts and nuts. This is a problem the industry created on its own. Honeywell is only responding to a need.

  • @tjrooger1092
    @tjrooger1092 3 роки тому +2

    Kind of funny, but in some neighborhoods in Texas, everyone is looking to go TO a heat pump. The reason is the housing developments are making sweetheart deals with utility suppliers. Those middle men are jacking up the price. On gas and or propane especially. High SEER heat pumps are cheaper to run, even with the electric heat strips.

  • @EvesterGaming
    @EvesterGaming 3 роки тому +1

    Just did an install yesterday that had 4 splices in the attic and two down the wall. Was amazed it even worked originally.

  • @gregmiracle9560
    @gregmiracle9560 3 роки тому +1

    Amazing someone didn't catch that! Just throw it together and hook it however you can get it to kinda work so we can get out of here!🤣 Glad you got it sorted👍 and awesome if you get to install gas unit! Gas is a great warm heat!!

  • @steveo601
    @steveo601 3 місяці тому

    I installed my own ecobee 3 several years ago. Color coded real easy. Seperate connection plate that the head until plugged into. Just had to go downstairs and write down what each wire ran to. My house was built in 1979, and not the original owner so going into any wall is seriously dangerous.😂. Luckily my wire bundle wasn’t previously hacked. It’s worth paying the 75 bucks more to get the ecobee over that one anyhow.

  • @TheWoodman064
    @TheWoodman064 3 роки тому +2

    Good job figuring that mixed up bunch of wires!

  • @rgb-c5
    @rgb-c5 3 роки тому +1

    Nice work fixing it. A new 410A heat pump with an old Rheem air handler? I'm glad you will be installing a new furnace. Make sure the equipment all matches. Chop and drop with a HP is a bad idea.

  • @dwight.bennett
    @dwight.bennett 3 роки тому +1

    I bet that quote includes the thermostat that has a screen that works right!
    I do notice that most of the products released since Resideo took over the Honeywell stuff have comparatively lousy documentation that lacks proper details and specifications.
    I think that particular thermostat with the screen that doesn't respond right to touch is begging for a target practice session!

  • @mrbillpro
    @mrbillpro 3 роки тому +2

    I have the Honeywell RTH9585WF1004, is a great stat, never had any issues with it. It's not like a cell phone, you have to use a little effort to change function's, and of course it helps if it's mounted on the wall. :-)

  • @benswafford8608
    @benswafford8608 3 роки тому +3

    They had the good elements with the green mark, the ones with the red mark would break and sling pieces through the duct

  • @Chris-oc9wu
    @Chris-oc9wu 3 роки тому +5

    the duct tape on the drywall really sets the tone. obviously our school system has failed us, sending to many kids to college instead of trade school.

  • @HVACGUY
    @HVACGUY 3 роки тому +3

    R-22 air handler, 410 condenser, probably never changed TXV as Rheem don’t make a conversion for it.

  • @jeffreywhitlatch1409
    @jeffreywhitlatch1409 3 роки тому +2

    Yep when you see a thermostat hanging by the wires you know, damn rookies, and I'm not talking about you. The electric heat isn't quite wired right in the air handler. White from the thermostat should go to White on the air handler for heat . The purple is wired into a evaporator freeze sensor , that is supposedly to turn on the heat to thaw out a frozen evaporator . which doesn't work anyway . Really he's got heat, up the wazoo. I used to wire the purple into the condenser circuit to open a condenser circuit if it froze up. The freeze sensor opens when it gets cold.
    Don't you hate working on heat when it's cold out. Can you imagine living up North. I'm in South Florida and it's been cold. I certainly enjoy watching .

  • @mostlikelywedoitservices6926
    @mostlikelywedoitservices6926 2 роки тому

    Since you share your knowledge. Here are some your way. CA glue and activator. If you run into sheetrock that is falling apart. Apply soak the sheetrock with the thin ca glue and hit it with an activator. The sheetrock will become hard to hold in wall fasteners. Works super great with towel bars in bathrooms.

  • @robertgaines-tulsa
    @robertgaines-tulsa 3 роки тому +2

    I'll never understand why someone needs such a sophisticated device for a thermostat.

  • @philmiller99
    @philmiller99 3 роки тому +2

    "Just bought this house recently"...came with the sea of leaves as a bonus. LOL!

  • @andyb.2582
    @andyb.2582 3 роки тому +1

    Great job troubleshooting that bad LV wiring!

  • @procharger94
    @procharger94 3 роки тому +13

    It's surprising how slow the touch screen is to react.

    • @Pentti_Hilkuri
      @Pentti_Hilkuri 3 роки тому +4

      Looks like a resistive touchscreen, you really need to ram your finger in those.

    • @3740westmichigan
      @3740westmichigan 3 роки тому +2

      They are that way !!!! Really long touch time !!!!

    • @isaiah4478
      @isaiah4478 3 роки тому +1

      @@Pentti_Hilkuri I agree i have the exact same one i need to press with some force to get it to register

    • @viralvideos6532
      @viralvideos6532 3 роки тому +1

      @Albo alt It's a WIFI thermostat, why would you even need to touch the screen?

  • @Straight_White_Fatherly_Figure
    @Straight_White_Fatherly_Figure 3 роки тому

    Hate when people use orange wire nuts for stat wire. Ive had to unrig wire messes like this myself. Good work!

  • @jdracer111
    @jdracer111 3 роки тому +2

    All the important tools are all in one pile in the truck that's the main thing. Right where you can find them.

  • @AIRCONDITIONINGSCHOOLING
    @AIRCONDITIONINGSCHOOLING Рік тому

    So even though orange was wire nutted to yellow and the thermostat called blue, yellow, and green in heat and blue was capped off outside, outside orange was obviously hooked up to the solenoid so everytime y called it was sending power to solenoid too because y&o were wire nutted, reversing valve still should have been energized even though the wiring is a bit screwed up. So it may be that, or is it energized in cool even though it's RUUD because they were tied together outside and solenoid worked?

  • @bills6946
    @bills6946 Рік тому

    I would install the gas furnace and keep the heat pump set up as dual fuel. Above 40 degrees outside, the heat pump provides heat. Under 40, the heat pump locks out and the furnace kicks in. I have that setup in my own house. Cheaper to run than straight furnace.

  • @JamesSmith-rl7nb
    @JamesSmith-rl7nb Рік тому

    Nice job Ted.
    True professional as always.sir.
    Enjoy your videos.
    I watch you,Cuties and Steve.
    Refreshing to see real pros .
    Ty sir

  • @russellhancock9765
    @russellhancock9765 3 роки тому

    I Think My Sister's Double Wide has those things. They use a Water Stove now and I unhooked their Electric Heat Strips except, I think I put a thermostat on one of them in case they ever needed the Electric Heat again.

    • @wskripka1
      @wskripka1 2 роки тому

      What's a Water Stove ?

  • @PlayingwithPawz
    @PlayingwithPawz 3 роки тому +2

    16:35 Holy hell look at all those spiders and I think one even jumped out at him. Oh hell no.

  • @J-Colt
    @J-Colt 3 роки тому +2

    Confusing mess! Thanks for video.

  • @moeselec
    @moeselec 3 роки тому +1

    Good luck with the new install.👍😊

  • @Gameboy_Steve
    @Gameboy_Steve 3 роки тому +1

    We have a lot of DYI hacks here also. Awesome video

  • @gr33n83
    @gr33n83 3 роки тому +2

    why go for gas heating when he got a heat pump ? i realy enjoy your Videos thank you

    • @oldhandyluke
      @oldhandyluke 3 роки тому +3

      Gas heating is a lot warmer than a heat pump.

    • @moorefilmltd
      @moorefilmltd 3 роки тому +2

      Depending on the area of SC he is in a gas furnace may be more efficient

    • @andykillsu
      @andykillsu 3 роки тому +3

      @@oldhandyluke Yeah so that doesn’t mean much especially when in the South... That heat pump alone can heat the house just fine for all but the very coldest of days in SC. He is just wasting his money to get the gas lines to the air handler.

  • @russellhancock9765
    @russellhancock9765 3 роки тому +1

    I don't ever remember seeing a Pink Wire in Thermostat wire before.

  • @bills6946
    @bills6946 Рік тому

    I didn’t see the option for change over setting to go from heat pump to strips. Is it set for 40 degrees?

  • @jaymarking7854
    @jaymarking7854 3 роки тому +2

    Why give up the Heat Pump, and going only gas?? You're in a warmer area to use Heat Pump as main heat, and use gas as back up?

    • @mr.t5334
      @mr.t5334 3 роки тому

      Depends on the cost of gas compared to electricity i guess

  • @abdullah_q8171
    @abdullah_q8171 3 роки тому +1

    Hi, is HITACHI scroll compressor 410 gas good ?

  • @SETX_Sirens_and_Rail_02
    @SETX_Sirens_and_Rail_02 3 роки тому +1

    I can agree with some of Rheem's older designs being absolutely terrible

  • @dmejia480
    @dmejia480 3 роки тому +1

    I always thought you run fan continuously to melt the coil instead of turning off the system

  • @dashcamandy2242
    @dashcamandy2242 3 роки тому +1

    The drain line dumps straight into a perforated corrugated footing drain pipe?... Why not just dump it out onto the floor, since it's gonna leak out anyways? LMAO
    I agree with you and the customer. Junk that old unit and get a nice gas unit in there.

  • @HoosierRallyMaster
    @HoosierRallyMaster 2 роки тому +1

    You can tell Ted is not an electrician - he picked up all the cuttoff bits of wire and insulation.

  • @anthony5530
    @anthony5530 3 роки тому +1

    Replacing the blower motor is a nightmare on those furnaces.

  • @rando_webb8704
    @rando_webb8704 5 місяців тому

    Looks like blue was set up for the reversing valve, and it was set up to be routed through the air handler control board you just bypassed all that with orange. Blue it still there it's just not doing anything.
    Personally I would have looked at all three places and their wiring before I started re-arranging the wiring. There was no need to set up the orange.

  • @steveg5576
    @steveg5576 3 роки тому +1

    Folks are going to Wago's...good case for them. Anyway, nice job.

  • @chaddarr4834
    @chaddarr4834 3 роки тому

    Where are you at state I swear that looks exactly like a job that I just had to redo all kind of stuff on and I’m in Alabama Tuscaloosaa

  • @bcotterman499
    @bcotterman499 3 роки тому +1

    Love your videos, but your voice volume is so low can barely hear you when you speak.

  • @pancho20006
    @pancho20006 3 роки тому +1

    What's the best thermostat for heat pumps?

  • @nathang.1744
    @nathang.1744 2 роки тому

    I really like old houses like that

  • @waterheaterservices
    @waterheaterservices 3 роки тому +2

    As a certified master hackman, I do not approve of this message.

  • @SirDeanosity
    @SirDeanosity 3 роки тому +1

    Ted: What temp is cold where you live and work?

  • @joeshearer1247
    @joeshearer1247 3 роки тому

    This is why you pay me the big bucks blue is common on Rheem for reversing valve and you could tell the b was hooked up on the old thermostat. Guaranteed service call when the homeowner tries to change the thermostat. I typed this before you went in the crawl space.

    • @TedCookHVAC
      @TedCookHVAC  3 роки тому

      I knew from sticker on t stat brown would be common... Full Air was a good company... his last name is Fuller.

  • @Hv1245
    @Hv1245 3 роки тому +1

    Even knowing how bad of a design that air handler is rheem still makes it

  • @brianmoore5498
    @brianmoore5498 3 роки тому +7

    go natural gas and dont look back. nice video, thank you.

  • @picklerix6162
    @picklerix6162 3 роки тому +1

    The duct tape is a nice twist. Connect that gas line up to a real furnace.

  • @brennangordon8568
    @brennangordon8568 3 роки тому +1

    I love the “hack job butcher” videos

  • @chrishilliker641
    @chrishilliker641 3 роки тому +1

    Gotta love the do it yourself home owners

  • @Heavy_metal_rulez
    @Heavy_metal_rulez 3 роки тому +1

    unlce Ted always coming to clean up some one else's mess

  • @Wolfhound.
    @Wolfhound. 3 роки тому +1

    wonder if they could have chosen a cheaper touch screen for there thermostats lol man oh man the response on that thing is crazy

  • @wskripka1
    @wskripka1 2 роки тому

    Is that heat pump more efficient than gas ?

  • @tycobb8621
    @tycobb8621 3 роки тому +2

    Looked like a damn Sno cone on that suction valve 😂

  • @gregoryfairchild2460
    @gregoryfairchild2460 3 роки тому +1

    Make you a wooden tray with dividers for your tool area..lol

  • @patmurphy2472
    @patmurphy2472 3 роки тому +1

    And , this is why you want a pro working on your stuff.

  • @waytospergtherebro
    @waytospergtherebro 2 роки тому

    One of the best things about not renting is being able to rip whatever space-age touchscreen bullshit somebody else thought was cool out of the wall and putting some quasi-legal mercury switches from eBay in their place.

  • @Ted_E_Bear
    @Ted_E_Bear 3 роки тому +5

    The “ Cowboy is on the job again “. !!

  • @GotchaplumberGotchahvac
    @GotchaplumberGotchahvac 3 роки тому +1

    Informative video.
    Are you an 864- guy?

    • @TedCookHVAC
      @TedCookHVAC  3 роки тому +2

      Yes, we are based out of Mauldin.

  • @flybyairplane3528
    @flybyairplane3528 3 роки тому +1

    Anti DIY HVAC, I actually had not seen that MH STAT before, but what a mess, & did they just lift it HANGING ? Never seen such crap before, ,, wonder why the stat was replaced, except this isDIGITAL
    then SCREW UP THE WIRING , WOW ITS A FEW YEARS OLD ALSO, SO ZYOU WILL NEED A GAS METER & piping for the new unit ! Cheers 🇺🇸🇺🇸🇺🇸🇺🇸

  • @maxeyac
    @maxeyac 3 роки тому +1

    Good job Ted.

  • @joeshearer1247
    @joeshearer1247 3 роки тому +1

    When you see a unit catty corner so the lines pipe right in with a 410a unit on the old r22 Evap that can only mean one thing......

  • @stephenb5757
    @stephenb5757 3 роки тому

    If you’d like that then you’re just a little bit different than me LOL great video

  • @jessethepondhopper8370
    @jessethepondhopper8370 3 роки тому +1

    Love it when they leave 2 inches of wire too work with lol

  • @howardshurst1302
    @howardshurst1302 10 місяців тому

    What do think of the thermostat?

  • @vasiliymironets8778
    @vasiliymironets8778 3 роки тому +1

    Some units still use blue for reversing valve

  • @lancerudy9934
    @lancerudy9934 3 роки тому +1

    Nice tool box!

  • @RVail623
    @RVail623 3 роки тому +1

    Maybe the Honeywell touch screen would react faster if you had first applied some kind of hand cream to your fingertips? Natural skin oils appear to be lacking in the video. Skin oils help conduct the micro electricity for the touch screen function to work properly. Also: at 19:19 there's 6 thermostat wires showing. Isn't 5-wire thermostat wire the standard? It will be interesting to see if new thermostat wiring is included if a new gas furnace gets installed. That existing Honeywell thermostat may also turn out to be okay, when it's operated by the home owner with normal fingertip lubrication.

  • @titanniki412
    @titanniki412 2 роки тому

    Could u use De Icer?

  • @thrilsekr565
    @thrilsekr565 2 роки тому

    R410a outdoor "matched" with an r22 ahu? Not gonna work

  • @roysuggs3635
    @roysuggs3635 2 роки тому

    T Stat default programs are for conventional ie gas heat.

  • @larrykeenan598
    @larrykeenan598 3 роки тому +3

    Nothing beats years of working experience in any trade. You don't learn how to analyze situations from a book.

  • @c_young-hvac4586
    @c_young-hvac4586 3 роки тому

    Was that a 410a capable coil in the air handler ....i was thinking that's a pre 410 mfd

  • @Garth2011
    @Garth2011 3 роки тому

    This buyer must have had a poor real estate agent helping him along. All of that should have caught prior to closing escrow. Maybe they did and he got credit and opted to fix things on his own but you would think the safety factors would have been asked for the seller to have corrected before they took possession of the house. Boy, they have enough leaves in the yard ! I'd get another thermostat too, that one is very nonresponsive to touch. If he goes with a new system then all will get replaced I'd presume.

  • @Ericbakereb1
    @Ericbakereb1 3 роки тому +1

    I hate that model of honeywell stat. Couple times my customer insists on keeping it when I replace the system. Then fight it to get it to work again. I'd rather give them a new smart thermostat free and save myself an hour of headache

  • @BYENZER
    @BYENZER 3 роки тому +1

    At 13:30, mm:ss, TED! That's AMERICAN ENGINEERING Sir!! Simplicity at it's BEST! Plus, unlike today's heat strip curlyQ's, those oven-like heater elements LAST! Also, those heat-sequencer snap-disc time delays last way longer than any COMPUTER board. Simple, easy, strait fwd, technician diagnostic friendly. WHAT MORE can you ask for?? What would you have done instead??

  • @primeministerofredneckistan
    @primeministerofredneckistan 3 роки тому +2

    I’ll go with heat pump and all electric any day . Screw having pressurized flammable gas running through my house. But I’m in the Deep South so it’s affordable.

  • @c_young-hvac4586
    @c_young-hvac4586 3 роки тому

    Was that a 410a capable coil in the air handler ....i was thinking that's a pretty 410 mfd

  • @jmo1809
    @jmo1809 3 роки тому +1

    to me the outdoor unit looks like a comfortmaker or some kind of icp

  • @SeanBaker
    @SeanBaker 3 роки тому +1

    That under house HVAC equipment was from 1873!!

  • @ryanthomas8004
    @ryanthomas8004 3 роки тому +1

    good stuff, thanks for posting this buddy

  • @oldhandyluke
    @oldhandyluke 3 роки тому +2

    Definitely looking forward to a possible future gas change over video, those are my favorite!
    #gasheatiswarmer

    • @andykillsu
      @andykillsu 3 роки тому +2

      #gasheathelpsgolbalwarming

    • @tomtom1541
      @tomtom1541 3 роки тому

      You've obviously never used an inverter heat pump. In other countries everyone is going from gas to reverse cycle to save money, inverter units can heat much faster.