high ampere problem in ac | split ac high ampere problem in ac | hindi

Поділитися
Вставка
  • Опубліковано 22 жов 2024

КОМЕНТАРІ • 27

  • @DilshadKhan-xq1bo
    @DilshadKhan-xq1bo 9 місяців тому +1

    Sir AP ko Dil se Salam karta hu AP jaise explain karte h n UA-cam per Kahi nhi h

  • @malikshahrukhmalikmuhammad2175
    @malikshahrukhmalikmuhammad2175 2 місяці тому

    Very good very nice
    Excellent

  • @repairingmyhobby
    @repairingmyhobby 4 місяці тому

    bhetreen bhot detail se samjhaya hai... ❤❤

  • @DilshadKhan-xq1bo
    @DilshadKhan-xq1bo 9 місяців тому +1

    Sir ji AP split ac ke fault par video bana dijiye

  • @shabnamperween6726
    @shabnamperween6726 2 місяці тому

    Sir interview me ek accha video banaye plszzzz

  • @DilshadKhan-xq1bo
    @DilshadKhan-xq1bo 9 місяців тому

    Thank you sir very good information properly 👍 Jo is video ko dekh lega wah ab high amp current ka trouble shoot kar lega

  • @jaanbaz1447
    @jaanbaz1447 4 місяці тому

    V good video

  • @cinematic2.0rajibkhan41
    @cinematic2.0rajibkhan41 5 місяців тому

    Sahi baat he sir

  • @saagarniazi8081
    @saagarniazi8081 3 місяці тому

    Sir mere pass full dc inverter h wo 10.5 ampere leta h aur 9 se nechy nahe ata kia waja h 1.5 month hoye leye?

  • @mudassarnazir6629
    @mudassarnazir6629 9 місяців тому +1

    Sir app both Tek terke se samjathy ha

    • @thetechhvac
      @thetechhvac  9 місяців тому

      Thank you for your comment! I appreciate your feedback.

  • @QADRI075
    @QADRI075 2 місяці тому

    Sir 16 amp lekar or voltas kam kr ke awaz kr ke dhad dhad ki band ho jaa rha hai compressor 2.3 mint me hi
    Please sir problem bata do capister bhi change kr diya hai

  • @rohityadav9475
    @rohityadav9475 3 місяці тому

    Split inverter ac 27 temp set kr k chlata hu to 7 ampere leta h
    Or jab 20 temp par set kr ke chlata hu to 15 ampere lekar trip ho jata hai
    Kya pcb mei falt ho sakta hai?

    • @thetechhvac
      @thetechhvac  3 місяці тому +2

      maybe..
      direct pcb tak pahonchne se pahle kuchh basic concept aur kuchh point main yahan per mention karta hoon to aap step by step follow kar sakte hain ..
      BASIC CONCEPT 👉 ( aap ne jo information di uske behalf par ) ho sakta ho jab tak aap 27 C temp. par ac on karte hon us samay compressor full load par nahi chal raha ho jiska matlab hai ki compressor ki kam speed yani kam pressure > low amps. > kam heating ( condensor ) lekin jaise aap 20 C temp, par ac on karte hain us samay full load par ac on hota hai jiska matlab compressor full speed par chal raha hai jiska matlab huwa high amps. > high pressure > high heating ( condensor ) ..
      POINT 👉 1- condensor coil dirty / ambiant temp. very high ( agar condensor ganda rahega to aisa ho sakta hai kyonki kam speed par itni heating nahi hoti lekin high speed / full load par jyada heat condensor se nikalti hai ) agar aisa hai to condensor coil clean kar len .
      POINT 👉 2 - compressor over current ( agar system main kahin se chocking hogi to compressor high amps. lene lagega aur jaise compressor ek fix amount se jyada amps. lega to pcb board ko maloom ho jayega to pcb board compressor par supply dena band kar dega . lekin ye koi ek reason nahi hai over amps. lena ka aise kai sare reason ho sakte hain jaise condensor coil dirty , ambiant temp. very high , gas over charge , IPM module faulty , compressor problem )
      POINT 👉 3 - PCB board faulty ( compressor trip karne ke kai sare reason ho sakte hain agar pcb bord main fault hai jaise - heat sink past weak , IPM faulty . ye kuchh basic point hain lekin ) agar aisa hai to kisi professional se PCB repair karwa sakte hain .
      UMMEED KARTA HOON AAPKE SAWAL KA JAWAB MIL GAYA HOGA 🤝 💚

    • @rohityadav9475
      @rohityadav9475 3 місяці тому

      @@thetechhvac thank you

  • @Motivate111
    @Motivate111 5 місяців тому

    Sir mera inverter ac ha 1.5 ton normaly 1 hour bbad 26-27 pe use krne se 2--.2.5 amp leta tha lekin ab 5 amp se kam he nhi ho raha kya problem hai..?

    • @thetechhvac
      @thetechhvac  5 місяців тому

      sabse pahle aap check karen ki servicing ki jaroorat hai kya ?

    • @Motivate111
      @Motivate111 5 місяців тому

      @@thetechhvac 15 din hue abhi service krvae hoe sir

    • @thetechhvac
      @thetechhvac  5 місяців тому

      room temp. agar maintain ho raha hai to phir aap kisi technician se check karwa len ki aisa kyon ho raha hai agar nahi maintain ho raha hai to isi wajah se bhi ho sakta hai kyonki abhi heating jyada ho rahi hai shayad pahle temp. jaldi maintain ho jata hoga is liye . aap ek aur kaam kar sakte hain aap raat ko apna AC chalu karke dekhe ki temp. maintain hone ke baad kitna amps. le raha hai agar normal hai to garmi ki wajah ho sakti hai agar phir bhi same problem aa rahi hai to kisi technician se ek baar chek karwa len.. 🤝😍

    • @Motivate111
      @Motivate111 5 місяців тому

      Btt aisa kaise ho skta hai sir 3 years se yhi ac use kr raha hu me same conditions me btt ab 2 days se ye problem ho gyi ha

    • @thetechhvac
      @thetechhvac  5 місяців тому

      everything is possible !