How to pass strong column weak beam check in ETABS Tutorial

Поділитися
Вставка
  • Опубліковано 13 січ 2025

КОМЕНТАРІ • 25

  • @EngineeringLearningPlatform
    @EngineeringLearningPlatform  3 роки тому +6

    Watch, "How to pass strong column weak beam check in ETABS Tutorial"

  • @zahidairfan6161
    @zahidairfan6161 3 роки тому +2

    strong column weak beam check was an awaited tutorial , thanks

  • @laythhasan518
    @laythhasan518 Рік тому

    thanks for sharing this video , I would like to ask , is it needed to use modifier 0.25 for slab in slab beam system, I checked ACI-318 - 19 for that and its written that its necessary for flat plates and flat slab

  • @adrianuslahiwu1002
    @adrianuslahiwu1002 2 роки тому

    are the wall loads include in mass source ??

  • @dilipngangom4198
    @dilipngangom4198 3 роки тому

    Does ETABS check the shear strength of Beam-Column joint as per IS:13920-2016 cl.9 over and above Strong column-Weak beam check? How can I verify the check?

  • @andresdavidtorrescarranza1953
    @andresdavidtorrescarranza1953 3 роки тому

    how can i check strong column weak beam if I have a intermediate sway? as We know, Etabs just calculates strong column weak beam for special moment frames.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 роки тому

      Didn't get the question

    • @andresdavidtorrescarranza1953
      @andresdavidtorrescarranza1953 3 роки тому +1

      @@EngineeringLearningPlatform Hi, thank you for aswering me, I mean, when I have a intermediate sway and I want to check 6/5 beam/column capacity ratios OR column/beam capacity ratios I get from Etabs N/A, it happens because Etabs Just calculates these capacity ratios for special frame moments, so as I mention before, I have a intermediate sway and I want to do these Checks. How can I check 6/5 beam/column capacity ratio in an intermediate sway?. In this video you are working whit a special frame moment so you can check 6/5 beam/column capacity ratio.

  • @Engrwaleed555
    @Engrwaleed555 3 роки тому

    AOA brother. Udemy par ju course ap me upload kia hai us mai detailing ka portion cover kia hai ap ne? I mean complete working drawings ju ham banate hein submission ke leye.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 роки тому

      No, it's an ETABS course primarily, but additionally design aspects are covered and you can check the topics covered on the landing page of course: www.udemy.com/course/etabs-rcc/?referralCode=4F571121E8073D773BE7

  • @gowthamiv4841
    @gowthamiv4841 3 роки тому

    its nice..what about the size of 24" x 24" by increasing column will it feasible to adopt though the member size passed???

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 роки тому

      Sorry the question is Unclear. However if a size is passing checks then there would be no reason to increase size

    • @gowthamiv4841
      @gowthamiv4841 3 роки тому

      @@EngineeringLearningPlatform 24" x 24 " size passed once 18"x18" not passed..but adopting of 24 " is feasible for residential??

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 роки тому

      @@gowthamiv4841 it is totally dependent on the project I cannot judge that without looking at drawings, it's an Engineer's call and judgement

  • @zahoorahmadnisar5841
    @zahoorahmadnisar5841 3 роки тому

    Can you please share any technical doc that how etabs calculates it.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 роки тому

      Go to Etabs help menu, click on manuals there you can see list of manuals of different codes, see for your code and the pdf manual will open

  • @civilideas1925
    @civilideas1925 2 роки тому

    👍🏻

  • @rcbsht9644
    @rcbsht9644 2 роки тому

    can you explain the color of column it displays as red pink and sometimes as black

  • @dibesshrestha796
    @dibesshrestha796 3 роки тому

    What does N/A mean in c/b capacity ratio

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  3 роки тому

      Mostly arises when the beam is not assigned "beam property" happens by mistake, or if the joint is not properly forming at common node or even releases can cause this issue.

    • @4ta01_josuadmarthrietchyri7
      @4ta01_josuadmarthrietchyri7 Рік тому

      @@EngineeringLearningPlatform How ti fixed it? please answer.

    • @EngineeringLearningPlatform
      @EngineeringLearningPlatform  Рік тому

      @@4ta01_josuadmarthrietchyri7 select the members, go to design and then "overwrite the frame design procedure" to correct one. If concrete so concrete or steel so steel

  • @zulkarnainbinmohdsalleh2024
    @zulkarnainbinmohdsalleh2024 11 місяців тому

    Confused…