4. SIEMENS S7 PLC Interface to ABB ACS880 Drives

Поділитися
Вставка
  • Опубліковано 18 гру 2024

КОМЕНТАРІ • 26

  • @murlimanohar1470
    @murlimanohar1470 7 місяців тому +1

    Could you please explain which parameter need to change for speed reference selection (Parmeter 22) for this FPBA-01 card control, I think I am missing something because I could start the drive from PLC (rotation sign on drive is on) but speed reference is not going to drive. Drive is sending few voltage when starts but speed ref zero( top right Hz is zero). I am using PPO5 for this.

    • @muhirfan5038
      @muhirfan5038 2 місяці тому

      please. I have a same problem

  • @khemrajsaroj7976
    @khemrajsaroj7976 3 роки тому

    Sir,
    It was very informative and good explained by you.
    I request you please make one video with Siemens PLC and ABB Drive with ABB Drive library.
    once again thankyou very much for video...

  • @shukhovukakumbi7189
    @shukhovukakumbi7189 2 роки тому

    @Average Engineer,is it possible to upgrade modus to profibus on abb drives?

  • @NA-ce1kq
    @NA-ce1kq 3 роки тому

    Thank you so much for expounding about the workings of status words and control words of a GSD. I just noticed that there were 2 rows under the ABB module PPO, the 4AX and the 6AX. You only use the IO address under 6AX row. What is the purpose of the 4AX row. Also, in some 3rd party device configuration there's a column that's called diagnostic address. Maybe you can explain to us on what is diagnostic address is for.

    • @averageengineer4266
      @averageengineer4266  3 роки тому

      The 6AX are the PZDs which i have used in the program for data transfer betw plc and drive. As u can see there are 6 inputs available for reading 6 values from the drive. So if you need to read more values you can use 4AX , which are the PKW, and this can be used to directly read from the drive parameter without any parameter configuration required.Using PKW for reading the values from the drive is a bit tricky though. You need to the write the HEX code of parameter group in first PKW output and Hex code of parameter number in second PKW output. The value of the parameter can be read in fourth PKW input. Confused?

    • @NA-ce1kq
      @NA-ce1kq 3 роки тому +1

      @@averageengineer4266 I got it! I hope you will also make a video for integration of Lenze Servo Drives 9400 HighLine with S7 controllers using PZD PPO. Lenze 9400 does not have a lot of information that can be found in YT. A lot of industries in the U.S. are using this drive. Thank you and hope you will continue sharing your knowledge.

  • @sanjidalamlesan8954
    @sanjidalamlesan8954 4 місяці тому

    Good and easy explanation. Thanks

  • @rincebaby145
    @rincebaby145 3 роки тому

    How operate the fieldweakning parameter of DCS800

  • @arnabram3389
    @arnabram3389 2 роки тому

    sir i cant dounload abb drive "ACS560-01-062A-4 + ACS-AP-S" gsd

  • @rexcheng4567
    @rexcheng4567 3 роки тому

    Perfect tutorial~ Btw, could you show the SFC14 for the ACS880 communication

  • @maheshbhilare6430
    @maheshbhilare6430 2 роки тому

    Nice vedio.... can you make one vedio on delta ss2 series plc with yaskawa v1000 drive

  • @wildlifedocumentary4964
    @wildlifedocumentary4964 2 роки тому

    Thanks for your video

  • @Rotartsinimda0
    @Rotartsinimda0 Рік тому

    Thanks for video

  • @niryashk9197
    @niryashk9197 3 роки тому

    Nicely explained

  • @rincebaby145
    @rincebaby145 3 роки тому

    Very nice video

  • @SharukhKhan-ig3pf
    @SharukhKhan-ig3pf 3 роки тому

    Amazing ❤️

  • @samadmallah-jd5oy
    @samadmallah-jd5oy Місяць тому

    Great

  • @muhirfan5038
    @muhirfan5038 2 місяці тому

    Please help me, in speed refference couldnot be responded if I give value from progam, I'm very gratefull if u can give me a phone number for asking my problem Mr.