6:15 Press and hold the fourth button (4th bay) for about 4 seconds, then the screen will no longer turn off by itself, the backlight will be on all the time
@@thejoker49 it's the same on the lii-600 that i own, just hold the first button until it beeps and release the finger, but i don't like to have the screen on for 24/7, so always a long press to take changes
if cells measure something like 0,5v or 1,7v, does that mean theyre dead? Because my Liito Kala doesnt want to charge them, it shows Null. Had to use Multimeter to read the voltage.
No, if u have one good charged Lithium cell just take 2 simple short wires and join your "dead" cell with the good one, positive pole with the positive, and both negative together for 10-15 seconds to activate the dead cell above ~ 2.8-3.5 Volt and put the one fast in the charger, it works always mate :) simple and easy
Always by discharging. You put the test mode on, setting the current for 500mA, it will fully charge to 4.2, than discharge to 2.8 V while doing the mesurement, and charging back to 4.2 and doing the second mesurement. On the end you will have two scores, by pressing the upper bay buttons you will see 2 different scores.
I have Liitokala 500s and I didn't find any video in Portuguese detailing how it works. I have the following doubt: I performed the 18650mah battery test and presented the results: - Charging 1881mha - Download 0886mha. Which value should you consider, loading or unloading?
Always the discharge value, but remember that u have to charge and discharge @ 500mA for the best results. But it seems your cell is damaged, the difference is to high, with a healthy cell the difference is around 1-3%, and not 50% like yours :)
6:15 Press and hold the fourth button (4th bay) for about 4 seconds, then the screen will no longer turn off by itself, the backlight will be on all the time
True? I will try mine
It works with any of the 4 channel buttons.
@@thejoker49 it's the same on the lii-600 that i own, just hold the first button until it beeps and release the finger, but i don't like to have the screen on for 24/7, so always a long press to take changes
LS always upto expectations 👍
I think this is better than the "Opus". Cause it doesn't have the annoying noisy small fan in it.
got a link to purchase? :P
if cells measure something like 0,5v or 1,7v, does that mean theyre dead? Because my Liito Kala doesnt want to charge them, it shows Null. Had to use Multimeter to read the voltage.
No, if u have one good charged Lithium cell just take 2 simple short wires and join your "dead" cell with the good one, positive pole with the positive, and both negative together for 10-15 seconds to activate the dead cell above ~ 2.8-3.5 Volt and put the one fast in the charger, it works always mate :) simple and easy
But... can you test the capacity by charging the battery ? i thought that has to be measured by discharging it !
he says in the video, the cycle is fully charge it and discharge it to know the capacity
You get shown the capacity pulled out and put in. The pulled out (discharge) amount is the actual capacity.
Always by discharging. You put the test mode on, setting the current for 500mA, it will fully charge to 4.2, than discharge to 2.8 V while doing the mesurement, and charging back to 4.2 and doing the second mesurement. On the end you will have two scores, by pressing the upper bay buttons you will see 2 different scores.
I have Liitokala 500s and I didn't find any video in Portuguese detailing how it works. I have the following doubt:
I performed the 18650mah battery test and presented the results:
- Charging 1881mha
- Download 0886mha.
Which value should you consider, loading or unloading?
Use download value, but I think your cell is damaged
Discharge is the accurate number. Charge is not accurate because there are losses due to heat
@@bobforte9343yes i think because the battery has internal resistance.
Always the discharge value, but remember that u have to charge and discharge @ 500mA for the best results. But it seems your cell is damaged, the difference is to high, with a healthy cell the difference is around 1-3%, and not 50% like yours :)
👍👍👍🙂
Those batteries are fake ones.
Definitively