How to Trigger Binary input on relay in pcm600

Поділитися
Вставка
  • Опубліковано 10 гру 2024

КОМЕНТАРІ • 22

  • @wasimulhaque2862
    @wasimulhaque2862 3 роки тому +1

    It's blur in contrast, so whenever make an video improve your video quality, but your video is very informative. Thanks bro👍

  • @meghanasr3098
    @meghanasr3098 3 місяці тому +1

    Hi sir can u make a video of protection testing of numerical relays like RED670, RET670,REB670. With parameter setting and calculation

  • @robertozelaya3193
    @robertozelaya3193 Рік тому

    you are a monster man...i love you 😘

  • @smsaranradzzworld9869
    @smsaranradzzworld9869 5 років тому

    hi whether it is possible to send a current to scada in percentage of full load current in REM615 relay

  • @ILAYARAJAraja
    @ILAYARAJAraja 3 роки тому

    Hi, In REF615 relay trigger continuously breaker on and breaker service signal in the disturbance record how can we stop continuously triggering, I need one trigger only at the time, kindly give the information,thanks..

  • @AdnanJayyousi
    @AdnanJayyousi Рік тому +1

    how can I add inputs to OR gate ?

    • @baranitech
      @baranitech  Рік тому

      ua-cam.com/video/b24OvcKYE0s/v-deo.html

  • @premkumar-xo5iz
    @premkumar-xo5iz 3 роки тому +1

    Binary output is not generating by ref615 relay when it receives binary input. How to solve this.?

  • @ILAYARAJAraja
    @ILAYARAJAraja 3 роки тому +1

    Hi how to solve ref615 relay modbus communication failure??

    • @baranitech
      @baranitech  3 роки тому

      i have only very less knowledge on modbus. anyway i will try to find solution can you please tell any error message your getting while. and also please ensure that modbus communication setting are correct

    • @ILAYARAJAraja
      @ILAYARAJAraja 3 роки тому

      @@baranitech ref615 have modus communication to dcs through anybus gateway, profibus communication ok up to anybus gateway converter in between relay to anybus gateway converter, there is communication failure, so how can we solve problem in the communication management in relay

    • @ILAYARAJAraja
      @ILAYARAJAraja 3 роки тому

      Finally answer found- menu-monitoring-communication-modbus-Ethernet-serial-Make it false to true, to enable modbus failure...

  • @pradeepsingh350
    @pradeepsingh350 Рік тому +1

    Sir I am unable to read in offline mode .. showing GPST error ...pls help me out

    • @baranitech
      @baranitech  Рік тому

      MAY BE THE SPECIFY CODE NOT MATCHING

  • @sureshpadhy2243
    @sureshpadhy2243 4 роки тому

    how to assign binary outputs to hardware outputs.

  • @ZDTcko
    @ZDTcko Рік тому

    My input stopped working over night. I measure full voltage on +- of the input, directly on relay. Its weird it just wont go from 0 to 1. Never happened to me before. Any thoughts on the problem, could relay input be broken? All setting are correct, on other bays same configuration works. Help sir pls 😢

    • @baranitech
      @baranitech  Рік тому

      you get any error code message in relay display