AMETEK 888 SRU TAIL GAS ANALYZER (AIMS)
Вставка
- Опубліковано 30 вер 2024
- The AMETEK 888 Air Demand Analyzer provides accurate tail gas analysis that is used in feedback control of their to acid gas ratio in sulfur recovery processes.
For more information please contact:
Office #103, 1st Floor, Al Khyeli Building,
Al Salam Street, Ground Floor RAK Ceramics
Beside ADCB, Electra Street
P. O. Box: 34915, Abu Dhabi
United Arab Emirates (UAE)
Tel: +971-2-6436114
Fax: +971-2-6436115
Email: info@aimsgt.com
Explanation is good but not in simple language..new guy will find difficulty to understand all terminoligies
Sir, Good and great explanation. Could you explain about the AMETEK ZE-900?
Nice video Zaheer , good job and great explanation.
I have two of these 888 and we are having temp at flange issue what can I do to fix that? We have changed out traps to have better regulation still faulting with that flange temp.
I have 6 of 880
Assalam-O-Alaikum how are you dear I have to talking with you about Nsl-880.
awesome , we are using the old TLG 837, i am not sure if it is reading correct because the H2S/SO2 ratio reads 25:0 and there is no correct indication for the H2S and SO2 analyzer, maybe the range is low, but however the air demand exceeds +/- 1.5 which means the process is off ratio
Jazakallah khair Bhai very excellent demonstration.
This really helps! Great crystal clear explanation! Expecting more videos!
Sir is any vacancy as an Analyzer Technician?
Great explanation and very clear.
I hope it is more maintenance friendly than the 880
Very good sir
Great explanation
Thanks Mr Zaheer
great explanation
Great.
Great Sir