How to configure Alarm in TIA Portal || With Example

Поділитися
Вставка
  • Опубліковано 25 січ 2025

КОМЕНТАРІ • 24

  • @franalonso9712
    @franalonso9712 Рік тому

    Thanks sir I think you saved half of my exam with this tutorial

  • @livefootballgy9804
    @livefootballgy9804 Рік тому +1

    Thank you! this really helped me.

  • @Maverickautomations
    @Maverickautomations 2 роки тому +1

    Great video sir we also working in automation field great leaving from your channel 👍

  • @IK-qu9hw
    @IK-qu9hw 3 роки тому +2

    Sir At 10:00 alarm tag data type is INTEGER why not bool or any other.....?
    Is it siemens protocol or anything else?

    • @IndustrialAutomation
      @IndustrialAutomation  3 роки тому +1

      Hello,
      This data type should be in the form of word that's why it's taken as integer.
      compulsary it should be in integer

    • @IK-qu9hw
      @IK-qu9hw 3 роки тому

      @@IndustrialAutomation ok then it's siemens protocol.

    • @patjebond
      @patjebond 2 роки тому

      @@IK-qu9hw Alarm view will look only at this integer and its bits, MW20 is 16 bits, so m20.0 - m20.7, m21.0 - m21.7 you can use for alarms

    • @hectorarturopachecosolis5885
      @hectorarturopachecosolis5885 5 місяців тому

      @@patjebond I don't understand the reason why the word MW20 being a 16 bits word, only comprises from m20.0 - m20.7. Can you help me to understand this?

    • @aman_khoja8820
      @aman_khoja8820 4 місяці тому

      No it comprises of M20.0 to M21.7

  • @mariosgr9585
    @mariosgr9585 2 роки тому +1

    Sir in 12:18 why the trigger bit is 8? Can you please explain that ?

    • @IndustrialAutomation
      @IndustrialAutomation  2 роки тому

      Hi..As per word format..it is First bit of word..

    • @ahmadalomari2128
      @ahmadalomari2128 2 роки тому

      hi
      are u under stand this point becuse same problem i have ?

    • @patjebond
      @patjebond 2 роки тому

      @@ahmadalomari2128 siemens does bit swap, which means 8 is first bit

  • @ganeshkhanderay2971
    @ganeshkhanderay2971 2 роки тому +1

    Sir please make video on alarm history how we can add screen of that and for checking log and history of alarm.

    • @IndustrialAutomation
      @IndustrialAutomation  2 роки тому +2

      Noted..will do soon

    • @patjebond
      @patjebond 2 роки тому +1

      On alarm view, choose "Alarm buffer" instead of "display current alarms", then it will save alarms that have happened before

  • @markmamaid2690
    @markmamaid2690 3 роки тому

    Sir, i have one question what if i got more alarms. And the M bit is M21.0 - M21.7. Do we need to add another alarm tag in plc tag and hmi tag with the address of MW21 or its done in trigger value, continueing the thr count of trigger value?

  • @hanamantballolli7884
    @hanamantballolli7884 Рік тому

    I required how to configure Alram history in Tia protal

  • @maziarbesanj1613
    @maziarbesanj1613 3 роки тому

    Tank you

  • @ziaurrahmankhan8790
    @ziaurrahmankhan8790 Рік тому

    Hello