Electrical Exam Prep for Electricians

Поділитися
Вставка
  • Опубліковано 16 вер 2024
  • You can find out more about the "electrical exam prep" subject you need to visit: ➡ fasttraxsystem...
    Our video is all about "electrical exam prep" topic information but we try to cover the subjects:
    -electrician exam
    -journeyman exam prep
    -electrical exam
    Electrical exam prep subject is showcased in lots of youtube videos, yet we tried to provide you the most effective details in a short and also understandable video.
    To find out more about this subject, please view the rest of this brief video and thank me later on.
    Do you wish to Embed the video?
    Below the video player, click SHARE button. After that Click Embed icon. From popup that appears, copy the code.
    The Autoplay feature on UA-cam makes it easier to decide what to watch next. After you see a UA-cam video, it will instantly play another related video based upon your viewing history.
    _________________________
    This Yt channel has other related video clips concerning electrician exam, journeyman exam prep and electrical exam Please check them out : / masterthenec
    I wish you liked this video clip where we covered as long as we could about electrician exam as well as journeyman exam prep

КОМЕНТАРІ • 7

  • @Alec-zh6ke
    @Alec-zh6ke 11 місяців тому +3

    Great teaching skills Mr . Paul

  • @jonathancobb3804
    @jonathancobb3804 3 місяці тому +3

    This is a much easier way to navigate the code book

  • @benjaminjones4914
    @benjaminjones4914 Рік тому +1

    ⚡️

  • @ryanutley1744
    @ryanutley1744 Місяць тому

    I thought that you load all breakers to 80 percent? I do commercial tho but is that like a test thing do you not take the 80 percent off usually?

    • @ryanutley1744
      @ryanutley1744 Місяць тому

      Or is this specific to the cord and plug loads

    • @MasterTheNEC
      @MasterTheNEC  Місяць тому

      Why would you only load a circuit breaker to 80% if its not a continuous load?. If its a 20 amp circuit breaker, its designed to handle 20 amps. Now, unless its rated for 100% of its rating, when you have a "continuous" load its only them you limit the load to 80% of the breakers rating.

    • @MasterTheNEC
      @MasterTheNEC  Місяць тому

      The rules in 210.23(B) are specific to cord and plug loads where you KNOW the loading. Not sure why folks think this applies to general use receptacle loads. For example, cord and plug in-sink waste disposal will apply to 210.23(B) but again not general use receptacles.