Cooling Tower Interview

Поділитися
Вставка
  • Опубліковано 2 чер 2021
  • Dear Viewers,
    In this video, there is 20 question over the cooling tower with their answers.
    Building Sanchalan
  • Наука та технологія

КОМЕНТАРІ • 190

  • @sonuking2859
    @sonuking2859 9 місяців тому +8

    Cooling tower ek heat exchanger ki tarah kaam karta hai

  • @rohanmohite4318
    @rohanmohite4318 2 роки тому +5

    Dear sir,
    This video is very much informative and helpful for interview.
    You covered most of the practical questions in it.
    Generally people always studies about theoretical concepts but stuck in interview in front of practical & conditional questions.
    I like this questions & answers and the way of your explaining is very nice.
    We need such videos like interview & practical questions on much more topics like Boilers, HVAC, Chillers, Compressors, Water system also in Mechanical seals, vacuum pump systems, Reactors, plant equipment etc.
    Please make videos on these topics also & guide us.
    Thank you so much........!!!!!!

  • @narendralakhara9846
    @narendralakhara9846 2 роки тому +2

    Sir aapka samjane ka tarika bahut sandar hai aur bahut badiya hai, kripya HVAC se related kuch video bnao sir, thankyou very much Sir 🙏🙏🙏🙏

  • @AbidHussain-zw3hl
    @AbidHussain-zw3hl 2 роки тому +4

    Hello sir how are you...I am wajid.i am Pakistani in asstant a.c technician I Dubai...your video is very important for us but some Hindi word I didn't know... please I request for u important word translation both Hindi and Urdu....thank you so much Sir.... good work a new jenration...

  • @rajeshjadhav00
    @rajeshjadhav00 2 роки тому +1

    Very informative video ... 👌🙏

  • @addikhan1029
    @addikhan1029 2 роки тому +1

    Thnx sir ... From Pakistan

  • @vaibhav9161
    @vaibhav9161 2 роки тому

    बिल्कुल पसंद आया है आपका वीडियो सर

  • @chinmayt5584
    @chinmayt5584 Рік тому +1

    very good explained. thank you sir.

  • @sreenivaskakani3620
    @sreenivaskakani3620 Рік тому +5

    very useful and important questions sir. Thank you so much sir.

  • @mdsadabalam9434
    @mdsadabalam9434 3 роки тому +14

    Extraordinary sir would you plz make video of HVAC interview questions

  • @shailendrajadon3599
    @shailendrajadon3599 3 роки тому

    Good information sir....

  • @pankajkhare83
    @pankajkhare83 3 роки тому

    Thanks, bahut achha

  • @jitendrajhafitness
    @jitendrajhafitness Рік тому +1

    You are best sir

  • @hemantsavale6492
    @hemantsavale6492 Рік тому

    Good example sir thank you so much

  • @sandeshpatil4015
    @sandeshpatil4015 Рік тому +5

    Sir, can you pls tell, what velocity to be consider in designing of Riser, header and water distribution pipe?

  • @huntergemerz2205
    @huntergemerz2205 2 роки тому

    Affect childrens life very much

  • @sonuking2859
    @sonuking2859 9 місяців тому +3

    Aur air bahar nikal jati hai aur air hamara thanda ho jata hai

  • @dps9828
    @dps9828 2 роки тому

    Very nice sir ji

  • @tejasparmartp6864
    @tejasparmartp6864 Рік тому

    Good explanation 🙌🙌🙌

  • @satyabanbehera1694
    @satyabanbehera1694 2 роки тому

    Sir make a video about HP1750 KW TECO motor company compressor.

  • @AkashYadav-df3yy
    @AkashYadav-df3yy 3 роки тому

    Sir plz ek video AFM or shift engg k upar b bna dijiye

  • @huntergemerz2205
    @huntergemerz2205 2 роки тому +1

    Under ground level area is very dangerous for tower. It affects our healths

  • @ajeetsinghmourya589
    @ajeetsinghmourya589 2 місяці тому

    Air compressor pr video banaye sir aur uski cost calculation per cfm bhi bataye sir

  • @ambujgupta8624
    @ambujgupta8624 Рік тому

    I am now fan of yours sir. Hats off to you.. what's aap number mil jaye apka to maja aa jaye .. very good way u have to make understand employee ,students .dhanyawad

  • @simarankumari-nn4st
    @simarankumari-nn4st 6 місяців тому

    Very helpful video

  • @mr.vinaytiwari3017
    @mr.vinaytiwari3017 3 роки тому

    Sir WTP interview Questions bhi bataiye.

  • @nitingothankar2601
    @nitingothankar2601 Рік тому +2

    What is corrosion rate in mpy in cooling tower acceptablee ?
    Efficiency of diffetent ct ?

    • @SAJIDKHAN-yk3vc
      @SAJIDKHAN-yk3vc Рік тому

      Drinking water ka pH 7.0 neutral hai agar water ka pH value 7+ me jayega to scalling aur 7 se kam me jaayega to corrosion hoga cooling tower ka acceptable range 7.5 to 9.5 pH k darmiyan hona chahiye.

    • @aditisoni2244
      @aditisoni2244 4 місяці тому

      Corrosion rate in mpy -
      Mils per year
      For
      MS metal

  • @rajukarmakar8424
    @rajukarmakar8424 11 місяців тому

    Thanks brother

  • @kamalazad8615
    @kamalazad8615 2 роки тому

    🙏🏻🙏🏻🙏🏻🙏🏻

  • @JakirHussain-ko3uf
    @JakirHussain-ko3uf 6 місяців тому

    Thanks

  • @kuldeepchavda7110
    @kuldeepchavda7110 Рік тому

    Nice knowledgeable video

  • @abidrazashakeb8457
    @abidrazashakeb8457 Рік тому

    Fabulous

  • @muhammediqbal9560
    @muhammediqbal9560 Рік тому +1

    How can we adjust fans blade degree?and Which degree recommend

  • @21harendra
    @21harendra Рік тому

    HTI holding time index kya hai sir kitne din tak cooling tower pani ko sump me rok sakte hai

  • @pkbaghelhnd8059
    @pkbaghelhnd8059 2 роки тому

    Good sir

  • @nareshtiwari5553
    @nareshtiwari5553 11 місяців тому

    Very nice❤❤

  • @thedream5525
    @thedream5525 2 роки тому

    Maximun efficiency induced draft

  • @shivrajrathor6438
    @shivrajrathor6438 Рік тому

    Acha samjaya h sir

  • @Olectra_oil
    @Olectra_oil Місяць тому

    Sir pls aap coolant water ushme konsa chemical dalaya jatahe pls bataye

  • @ramanlal8693
    @ramanlal8693 2 роки тому

    Good

  • @manojkumar-jg1lf
    @manojkumar-jg1lf Рік тому

    Sir ji UPS ki bhi video bnao

  • @truthfulbillionaire8610
    @truthfulbillionaire8610 Рік тому

    Sir ji Boiler and Chilled water ka video banao sir

  • @samhaazratechnicalsupport
    @samhaazratechnicalsupport 10 місяців тому

    Good sir ❤❤

  • @dhanrajdunekar900
    @dhanrajdunekar900 3 роки тому +3

    Why cooling tower efficiency is low in rainy days ..

    • @mdsadabalam9434
      @mdsadabalam9434 3 роки тому +1

      Because in rainy season there are high realative humidity in atmosphere

  • @sarveshrao1042
    @sarveshrao1042 Рік тому

    Sir screw type compressor ka interview type questions lacture upload kriye

  • @PankajKumar-le6pv
    @PankajKumar-le6pv Рік тому

    Nice sir 👍👍

  • @stutiswaraj3143
    @stutiswaraj3143 11 місяців тому

    Bahut achaa

  • @samirnimbalkar7248
    @samirnimbalkar7248 3 роки тому +1

    Mee plant video banav

  • @bharatchandrabarik6724
    @bharatchandrabarik6724 5 місяців тому

    Hello...how it possible efficiency low in Rainy Season??? Please explain.

    • @BuildingSanchalan
      @BuildingSanchalan  5 місяців тому

      Due to increasing humidity, u may check practically

  • @rustamansari3663
    @rustamansari3663 7 місяців тому

    Sir ek video Aisa hi AHU pr banaye interview ke liye

  • @SHASHIKANT-ct8vt
    @SHASHIKANT-ct8vt 2 місяці тому

    Suprb

  • @sunitajohn3715
    @sunitajohn3715 2 роки тому

    Sir hum Kisi chiller ka kesy pata kar sakhta he Kitne ton ka ha is kea video send karea

  • @tkuv3851
    @tkuv3851 8 місяців тому

    plz upload a video based on Electrical engg- FM

    • @BuildingSanchalan
      @BuildingSanchalan  8 місяців тому

      ua-cam.com/video/s1VfWYyQpt8/v-deo.htmlsi=VAt4q7O8skezfX3H watch it

  • @anilsiv6869
    @anilsiv6869 2 роки тому

    Cooling tower header distributor the pipeline with nozzle and sprinkler

  • @huntergemerz2205
    @huntergemerz2205 2 роки тому

    Electronics and mass communication

  • @ajadsteelkshiprampdewas4162
    @ajadsteelkshiprampdewas4162 2 роки тому

    Sar tr se Kuling taver ki saij nikalna btaye

  • @dhanrajdunekar900
    @dhanrajdunekar900 3 роки тому +3

    Cooling tower can cool water up to wet bulb temp. That's OK but what should be return water temp. My meaning how much difference should be there in cooling tower outlet water and inlet water..?

    • @BuildingSanchalan
      @BuildingSanchalan  3 роки тому +1

      As per standard 8 c but practically 10 to 15 degree c

  • @erajmal8049
    @erajmal8049 Рік тому

    Sir.. Hm se question kiya gya tha chiller aor cooling me TR kiska jyada hota hai... Pls btae

  • @vijaypawar-oq5xw
    @vijaypawar-oq5xw Рік тому

    sir ji aocp attendant operator chemical plant interview ek video banao sir

  • @Ravichauhan-lc6jt
    @Ravichauhan-lc6jt Рік тому

    Sir ji aap denfoss compressor oil less per video bnaiye sir

  • @razvivlogs96
    @razvivlogs96 Рік тому

    Cooling tower ke pani ko kaise balance karte hai

  • @sumitkumar-nc8vm
    @sumitkumar-nc8vm Рік тому

    Cooling tower me ...PH ....TDS .. HARDNESS..CHEAK KRTE H ....OR en se alag or kya kya cheak krte h parameters me sir ji

    • @BuildingSanchalan
      @BuildingSanchalan  Рік тому

      ua-cam.com/video/Aj4tKJDPgQ0/v-deo.html Watch it. Many videos in Channel playlist cooling tower.

  • @hengineeringmind1647
    @hengineeringmind1647 Рік тому

    Sir cooling Tower me jo CT Fan Laga Rahta Hai wah Fan kis Tarah Kam Karta Hai hawa ko bahar nikalta Hai ya Bahar Ki hawa ko Cooling Tower me dalta hai

  • @samhaazratechnicalsupport
    @samhaazratechnicalsupport 10 місяців тому

    Every niece

  • @mamtasandeep5020
    @mamtasandeep5020 Рік тому

    Sir
    ac & hvac syllabus per ek video banao sir

    • @BuildingSanchalan
      @BuildingSanchalan  Рік тому

      Antiscallant, NaoH and de scaling chemical whenever required

  • @haddkardiaapne8447
    @haddkardiaapne8447 Рік тому

    Humidity ke baare m kuchh bataaye ? How to calculate ?

    • @SAJIDKHAN-yk3vc
      @SAJIDKHAN-yk3vc Рік тому

      DBT Dry bulb temperature -WBT Wet Bulb temperature ka jo difference aata hai usko humidity chart me dekh k pata kiya jata hai formula se calculation bhi kiya ja sakta hai lekin mostly chart se hi dekha jata hai. sling psychrometer se DBT aur WBT ka pata kiya ja sakta. Agar difference zero aaya to 100% humidity hai difference jyada rahega to humidity kam rahega

  • @shaikshaboddin1365
    @shaikshaboddin1365 2 роки тому +1

    Specific heat of water moderately change with temperature. Process water having the above 30°c that time cp will change.

  • @moonshiekh1100
    @moonshiekh1100 2 роки тому

    Sir CT ki efficiency sabse jayda achhi winter me hoti h but kyun hoti h ye batiye ? Or sabse kharab rainy season me hoti h but kyun hoti h ye batiye sir ???

    • @BuildingSanchalan
      @BuildingSanchalan  2 роки тому +1

      Winter mosam thanda aur dry hota h aur humidity kam hoti h.
      Rainy season me humidity bahut jyada hoti h

    • @BuildingSanchalan
      @BuildingSanchalan  2 роки тому

      Bhai, winter me
      1 evaporation sabse jyada hota h
      2 wet bulb temp badh jaata h
      3 approach badh jaati h .
      4 range badh jaati h
      5 isliye efficiency badh jaati h
      Efficiency=range*100/range+approach.
      Yadi tum nahi samajh paaye to m ak video bhi bataunga.

    • @moonshiekh1100
      @moonshiekh1100 2 роки тому

      @@BuildingSanchalan got it sir

  • @huntergemerz2205
    @huntergemerz2205 2 роки тому

    Electrical components is also dangerous

  • @TechnicalSkillwithVK
    @TechnicalSkillwithVK Рік тому

    Sir cooling Tower water ko WBT ya DPT, inme se kis temp tak water ko cool karta h

    • @BuildingSanchalan
      @BuildingSanchalan  Рік тому

      WBT tak kiya ja sakta ha parantu practically 3 - 4 degree jyada rahta ha.

    • @TechnicalSkillwithVK
      @TechnicalSkillwithVK Рік тому

      @@BuildingSanchalan
      Sir mai samajh nhi paya.
      Ex- DBT - 30'C, WBT- 24'C, RH- 61%, DPT- 21'C, Cooling Tower entering temp- 38'C h to cooling Tower theoritically and practically water ko kitna cool karega

    • @BuildingSanchalan
      @BuildingSanchalan  Рік тому

      @@TechnicalSkillwithVK 33 to 34 degree C

  • @MohitTyagi-pt8lq
    @MohitTyagi-pt8lq 2 роки тому

    What is difference in oxidizing and nonoxidizing

    • @BuildingSanchalan
      @BuildingSanchalan  2 роки тому

      Oxidizing , which matters reacts with oxygen and causes of corrosion. Due to it all MS material deteriorates.

  • @ArunYadav-xy8sz
    @ArunYadav-xy8sz Рік тому

    Ducting par bhi vedio banaiye

  • @ashvendrasen7171
    @ashvendrasen7171 Рік тому

    Foph ke bare me video banaye sir

  • @adarshprakashmall8348
    @adarshprakashmall8348 2 роки тому

    CLO generator cooling Tower mai kyo use karte hai aur kya parameter limit hai.

  • @funnyvideo7252
    @funnyvideo7252 Рік тому +1

    Sir maine civil engineering kiya h aur , cooling tower me kam bhi krta hu to , mujhe age badhne ke liye cooling tower me age groth hai ki nhi sir plzz reply????🙏🙏

    • @BuildingSanchalan
      @BuildingSanchalan  Рік тому +1

      civil enginnering cooling tower match nahi karta. Achha hoga aap apna profession chune parantu jab tak koi achha option na mile mat chodna.

    • @funnyvideo7252
      @funnyvideo7252 Рік тому

      @@BuildingSanchalan ok sir

    • @Manishyadav-mz7gk
      @Manishyadav-mz7gk Рік тому

      ​@@funnyvideo7252 dost koi vacancy hai tell me plz 🙏

  • @anilsiv6869
    @anilsiv6869 Рік тому

    Humidity Jab badhegi to cooling tower ki efficiency kam hoga

  • @sonuking2859
    @sonuking2859 9 місяців тому

    Cooling tower Pani aur air ko ek sath me Lata hai

  • @dps9828
    @dps9828 2 роки тому

    my Sr.operator DM plant

  • @HarishKumar-nv5nd
    @HarishKumar-nv5nd 3 місяці тому

    Heat exchanger k imortant quetion baniya na

  • @chiragprajapati4853
    @chiragprajapati4853 Рік тому +1

    Sir M3/hr ko TR ME KAISE CONVERT KARE??

    • @aditisoni2244
      @aditisoni2244 4 місяці тому +1

      M3/hr circulation rate hai pump ka
      TR tonnage Refrigeration hai
      Dono ka aapas me koi relation nahi hai

  • @huntergemerz2205
    @huntergemerz2205 2 роки тому

    Weathers

  • @pradeepchoudhari9433
    @pradeepchoudhari9433 5 місяців тому +1

    How to condesr load 70% pay approach 1.5 chahihy how to solve plz

  • @sonuking2859
    @sonuking2859 9 місяців тому

    Aur pani ki heat ko air me transfer karta hai

  • @huntergemerz2205
    @huntergemerz2205 2 роки тому

    Earhquack investigation

  • @huntergemerz2205
    @huntergemerz2205 2 роки тому

    Trignometry

  • @rajgaud5647
    @rajgaud5647 Рік тому

    Sir ro plant ka cip process video daliye

  • @sameerthombre1592
    @sameerthombre1592 11 місяців тому +1

    Cooling tower me TDS Hardness and conductivity range kitni honi chahiye

  • @swapnilmule
    @swapnilmule 2 місяці тому

    TDS Kitna Rakhte hai?

    • @BuildingSanchalan
      @BuildingSanchalan  2 місяці тому

      Channel ( Building Sanchalan) ke community tab me dekh sakte ha.

  • @shekharyadav8456
    @shekharyadav8456 Рік тому +1

    Qualification kya hona chahiye sir ji 🙏🙏❤️

  • @sunitajohn3715
    @sunitajohn3715 2 роки тому

    Who drive the chillers ton formula video

    • @BuildingSanchalan
      @BuildingSanchalan  2 роки тому

      In building sanchalan channel, pls visit HVAC PLAYLIST definitely u will get your answer of many questions.

  • @mostafamah3201
    @mostafamah3201 2 роки тому

    Would you please write English text on the board??? i dont know any about Indian handwriting

  • @mashrurneyaj1833
    @mashrurneyaj1833 Рік тому

    Aap to har question me bolte ho is ke bade me my dusra video banaya hai😀

  • @ShaniKr95
    @ShaniKr95 Рік тому

    Sir cooling tower ka TDS kitana hota

    • @BuildingSanchalan
      @BuildingSanchalan  11 місяців тому

      ua-cam.com/video/Aj4tKJDPgQ0/v-deo.htmlsi=2F_7htTd7QquhG7s watch it.

  • @sumitkumar-nc8vm
    @sumitkumar-nc8vm Рік тому

    Cooling tower ki efficiency rain 🌧️ ke time jyada khrb hoti h. ...kyu.....

  • @lalandhiwar6592
    @lalandhiwar6592 3 роки тому

    Dm plant ke bare me

  • @mohmadirfan3623
    @mohmadirfan3623 2 роки тому

    Sir wet bulb temr kise kahte h

  • @abidrazashakeb8457
    @abidrazashakeb8457 Рік тому

    But sir hwt & cwt ko kaise find krenge

    • @BuildingSanchalan
      @BuildingSanchalan  Рік тому

      HWT ke liye cooling tower ki in line water ka temperature check kare ,CWT ke liye out line ke water ka temperature check kare.

  • @shahjahankhan8459
    @shahjahankhan8459 Рік тому

    Sir dosing kya hota hai

    • @BuildingSanchalan
      @BuildingSanchalan  Рік тому +1

      केमिकल को थोड़ा-थोड़ा पानी में ऐड करते हैं पंप के द्वारा छोटे-छोटे पंप आते हैं

  • @paramveermali577
    @paramveermali577 2 роки тому

    Sir cooling tower ka ∆T to hamesa change hota rhata hai to acuret TR kaise nikale

    • @BuildingSanchalan
      @BuildingSanchalan  2 роки тому

      Dear CT ke parameter jaldi change nahi hota matlab delta T change nahi hota

  • @chandanjiofficial3280
    @chandanjiofficial3280 2 роки тому

    Sir course kr bate h kya