Analog input complete loop drawing from field to DCS | Instrument Guru

Поділитися
Вставка
  • Опубліковано 27 жов 2024

КОМЕНТАРІ • 32

  • @alikhanzulkashov4438
    @alikhanzulkashov4438 4 роки тому +1

    I learned so many things from your videos, thank you so much, but most of the time, I struggle with the content just because I don't understand the language, you make valuable lessons, so I thought if it was possible to add Englsih subtitles to your videos for better understanding, because I am pretty sure that englsih speaking learners just like me also watch your videos. Thanks in advance!

  • @Usman.9234
    @Usman.9234 5 років тому

    Very good imformation videos sir thank you

  • @aazibification
    @aazibification 5 років тому

    Nice work bro. Thanks a lot

  • @suhail8086123757
    @suhail8086123757 5 років тому +2

    Sir.your vidoes are superb..can u plz do a video about commisioning activities or details and documents required during commisioning

  • @vijaypatani9205
    @vijaypatani9205 5 років тому

    Thanks Dost

  • @hammadahmed00
    @hammadahmed00 5 років тому

    nice work bro thank a lot

  • @jaydeepmahida5635
    @jaydeepmahida5635 5 років тому

    nice work sir...

  • @basicindustrialinstrumenta966
    @basicindustrialinstrumenta966 5 років тому

    Thanks sir

  • @syedmohammadsaif8344
    @syedmohammadsaif8344 5 років тому

    Plz show the practical of this loop wiring cable termination

  • @rajeshg4536
    @rajeshg4536 5 років тому

    Thanks bro

  • @MayurBuzz
    @MayurBuzz 4 роки тому

    Bro please explain 4 wire active signal universal i/0 signal

  • @instrumentpower6380
    @instrumentpower6380 2 роки тому

    Sir yadi main DCS AI elco board me supply check karu to kya milega tatha AO elco me

  • @syedmohammadsaif8344
    @syedmohammadsaif8344 5 років тому

    Plz make videos for a precommisiong & commissioning in oil& gas, thanks

  • @shivaprabhu.s.havinal6276
    @shivaprabhu.s.havinal6276 5 років тому

    Thanks for your nice vedio can u plz explain about cards, boards, domain and station

    • @InstrumentGuru
      @InstrumentGuru  5 років тому

      Video is available on channel about DCS system. pls visit video section of the channel

  • @rajann106
    @rajann106 5 років тому

    Thank you. I want displacer level tranmiter explain with modal numbrt.

  • @maheshpawar562
    @maheshpawar562 5 років тому

    Sir, kya PLC loop wiring mein bhi ALCO board use hota hai???

  • @renjithksa
    @renjithksa 5 років тому

    Brother, can you please explain what is the reason for control valve hunting? How we can troubleshoot

  • @rajann106
    @rajann106 5 років тому

    Double acting control valve explained

  • @prashantnikam5077
    @prashantnikam5077 5 років тому

    Hi..
    please reply me purpose of cable shield ground,
    Also why ground shield at cabinet side , not on instrument field side.
    Waiting for your reply..

    • @syedmohammadsaif8344
      @syedmohammadsaif8344 5 років тому

      For ic sheilding is done on one side for reducing interference effect

    • @uddipansarkar404
      @uddipansarkar404 4 роки тому

      A shielded cable has a protective aluminium foil to which the tinned shield/drain wire is internally fully connected...now when an interference is induced on the cable ,the primary PVC insulation should block it...if still some high frequency signal gets through it, then it is blocked by the aluminum foil and is grounded by the shield at the cabinet side...if we connect at both the ends , then a ground loop is formed again, which serves as no purpose for removing crosstalk or interference. Also it is wrong to say that every time a shield is always terminated at cabinet end. For many low range signals such as thermocouple etc. they are not terminated at cabinet side...now why is that, I would leave it to you so that you can find it on your own and in the process gain knowledge by reading different international standards and articles.
      Good luck!

  • @prakashakumarpati3824
    @prakashakumarpati3824 5 років тому

    Bhai please tell me difference between earthing and shielding

  • @syedarmaan655
    @syedarmaan655 5 років тому

    Sir aapne CONTROL VALVE ka CV value ka video ab tk kyu nahi banaya ?
    Maine kai bar aapko bola banane ko aur aapne ek video Mai bhi bola tha Control valve ka CV value ka video banaunga but aapne abi tk nahi banaya...
    Please bana do... it's very important..
    Mujhse kal interview Mai pucha gya tha but Mai nahi bata paya ...

  • @waqarkhattak729
    @waqarkhattak729 5 років тому

    DI, DO, SAI, SAO, SDO, SDI please elaborate these

  • @masumahmed7978
    @masumahmed7978 Рік тому

    Elko board what?

  • @jaydeepmahida5635
    @jaydeepmahida5635 5 років тому

    marshaling panel me t. b me nhi jayenga

    • @insanthereal3975
      @insanthereal3975 5 років тому

      Signal wiring enters from TB side in MAR CABINET ..from the opp side internal wiring is done upto BARRIER attached to a backplane ...from there it reaches SYSTEM CAB via ELCO CABLE ...

    • @InstrumentGuru
      @InstrumentGuru  5 років тому

      you can install TB in marshalling cabinet but u can also connect directly to the barrier.

    • @insanthereal3975
      @insanthereal3975 5 років тому

      Yes we can...bt its look more composed and managed with the TB

  • @syedmohammadsaif8344
    @syedmohammadsaif8344 5 років тому

    Branch cable PT or TT se jn box pe jo aarhi he wo kitne pair ki he ,main cable to 16 pair he