346 Wrapping

Поділитися
Вставка
  • Опубліковано 9 вер 2024

КОМЕНТАРІ • 18

  • @brad349miller
    @brad349miller 5 років тому +7

    We just watched this in class. “Twizzers.” Don’t worry. I have Performance anxiety too. 🤣🤣🤣

    • @yaetheyoutuba4950
      @yaetheyoutuba4950 2 роки тому

      im watching in class now and i was the only one who caught this

  • @juliajackson6855
    @juliajackson6855 9 років тому +5

    indicator tape is insufficient as an internal pack release per the AAMI ST:79

  • @satheeshav.n8080
    @satheeshav.n8080 7 років тому +4

    especially do not use this method in hospital

  • @xOxGingerGrlxOx
    @xOxGingerGrlxOx 6 років тому +2

    this would make me fail my test. DO NOT DO THIIIIIS!!!!!!

  • @tedcabana
    @tedcabana 2 роки тому

    How long does it take to cook a ham in the autoclave?

  • @rajeshkumarsara8478
    @rajeshkumarsara8478 7 років тому +2

    do not use this method in daily hospitality hospital

  • @sukumaranadarsh5644
    @sukumaranadarsh5644 6 років тому +4

    what She doing !!! dont do this One

  • @heathervillegas1565
    @heathervillegas1565 5 років тому +1

    Her wrapping technique is utterly horrendous! No scrub or nurse would accept that package as sterile. No No No No No! First of all you need an integrator in ANY item being processed for sterilization. A piece of steam tape is an unacceptable indicator inside any wrapped or peel packed item. Second your corners should come to a point and no raw edges should be visible once tucked under. One piece of steam tape should run down either side of your pull tab and nothing should run length wise. Pull your sides over so that the majority of the top of the item is covered. Then affix your label to the item. If you are new to this profession DO NOT do what she is doing! It is completely WRONG.

  • @emilyjeffords5907
    @emilyjeffords5907 3 роки тому

    If that is an envelope fold, it's done wrong!

  • @jemmabingham6560
    @jemmabingham6560 3 роки тому

    Where is the integrator and tip protectors!! This is not a sterile pack!!!!

  • @blkcubwhtbear5361
    @blkcubwhtbear5361 5 років тому +4

    All that info and the folding is wrong

  • @jemmabingham6560
    @jemmabingham6560 3 роки тому

    No No!!! No !!!

  • @canadamedicalltd.6710
    @canadamedicalltd.6710 5 років тому +2

    out dated....

  • @mmssaa14
    @mmssaa14 5 років тому +2

    DO not use your hands without Gloves

  • @preciouss917
    @preciouss917 2 роки тому

    Wrong!!!!