Profile-free earthing and short-circuiting of railway overhead lines
Вставка
- Опубліковано 5 лют 2025
- For safe work on and in the track, the railway overhead line must be disconnected and earthed and short-circuited. This protects people and materials in the event of accidental reconnection and dissipates the inductive voltage that is present at life-threatening levels even after the line has been disconnected. If supply vehicles are also used on the affected track section during the work, profile-free earthing and short-circuiting is carried out. This means that the conductive connection between contact wire and earth is established in such a way that driving is still possible. Work is carried out according to the 5 safety rules. This video shows rules three and four, establishing absence of voltage and earthing and short-circuiting.
Equipment used:
• KP-Test 5R voltage detector, 5-piece
• Single-pole earthing and short-circuiting device
• Contact wire earthing clamp P51D
• Rail earthing clamp R50
• Earthing pole (5-piece)
Finde out more:
www.pfisterer....
Thanks for sharing I always want to know how they ground the high voltage line.
Putting the hot stick on the dirty ground before use is never a good idea