Profile-free earthing and short-circuiting of railway overhead lines

Поділитися
Вставка
  • Опубліковано 5 лют 2025
  • For safe work on and in the track, the railway overhead line must be disconnected and earthed and short-circuited. This protects people and materials in the event of accidental reconnection and dissipates the inductive voltage that is present at life-threatening levels even after the line has been disconnected. If supply vehicles are also used on the affected track section during the work, profile-free earthing and short-circuiting is carried out. This means that the conductive connection between contact wire and earth is established in such a way that driving is still possible. Work is carried out according to the 5 safety rules. This video shows rules three and four, establishing absence of voltage and earthing and short-circuiting.
    Equipment used:
    • KP-Test 5R voltage detector, 5-piece
    • Single-pole earthing and short-circuiting device
    • Contact wire earthing clamp P51D
    • Rail earthing clamp R50
    • Earthing pole (5-piece)
    Finde out more:
    www.pfisterer....

КОМЕНТАРІ • 2

  • @lylewatts6370
    @lylewatts6370 7 місяців тому

    Thanks for sharing I always want to know how they ground the high voltage line.

  • @imeprezime1285
    @imeprezime1285 Рік тому

    Putting the hot stick on the dirty ground before use is never a good idea