(Mera matlab company se liye Jane wali jail se tha ) hamare new Burwell mein pump dal ke Chala rahe hai to usme niche se ret ka blockage ar hai aur ret pump ko jam kar De raha hai agar koi solution ho to please bata dijiye🙏🙏
@@rohankanu9880 company ke sath jo jali mila hai jarur use karne Submersible ko lagane se pehle borewell me chips ( giti ) dhal dete tab neeche ganda upper nhi aa pata
Bhai ...abhi nya borewell kraya h 270 ft tk casing pipe h jisme 6 filter pipe h aur motor 230 ft me h 5 din ho gye balu aa rhi ret aur kali balu ....iska kya solution h ??? ....jldi btana bhai
@@Easy_fit column pipe 20 hi pade the pahle motor c.r.i. ka h 1.5hp/15 stages ka h pani ka flow km aa rha tha to 3 pipe badhaye h ...jisse abhi flow to accha aa rha h bs kali balu aur ret aa rhi
Sir abhi 4 din pahle bor karwaya hai 180 fit aur chalu krte hai to pahle saf pani ayega 1 min tak fir ganda ane lgta hai aur 1 min bad fir se saf pani dene lgta hai
Hmne borewell 300 feet ka karwaya hai ... jisme 110 feet casing pipe Dali hai...pani 90 feet me aa gya tha.... submersible pump lgaane pr usme ret aa gyi or vo chalna bnd ho gyaa ...humse pump nikaal ke safai kewai or upr se net baabdh ke fr pump dala ...kuch der pani aane ke baad fr pani aana bndho gya ..kya krna chahiye
@@anmolchawla8080 borewell wale ko bol ke ache se flashing karwana hoga warna baar baar pareshaan rahiye ha Or galti se casin pipe creak huwa hoga to or problem ho sakta hai
Bhai maine 18 mahine pehle summer sabil lgwaya tha 230 ft Shuru ke 6 months me use 4-5 baar hi chlaya pr pichle ek saal se daily chl raha h phir bhi usme barik reta aa raha h 15 minutes chlaenge to usme 5-6 minutes reta aata h Kya iska koi solution h
Sir mere borewell m ganda pani aa rha hai 2 - 3 din se and 2 - 3 minutes ke bad pani dena band kar deta hai... Or borewell purana hai chapakal ko hata kr usme submersible pump dale hai... Ky karan ho skta hai sir plz reply jrur kare
Sir please please help me🙏🏻.. Sir ek saal pehle maine 250feet boring karwaya thha..185feet mai pani aaya thha..casing 89feet tak hai..1hp ka submerssible motar lagwaye thhe...1 saal achchha pani diya...,,..1 saal chalne ke baad motar kharab ho gaya tow..naya motar lagaye...2024 mai....abhi naya motar lagane ke baad 5 se 6 minute pani dene ke (200 litter pani aata hai)..baad Pressure ekdam down ho jata hai..please 🙏🏻..sir bataye isme motar ki kharabi hai ya..borewell mai pani kam ho gaya hai..??...bahat paresan hu..sir..please reply kare🙏🏻
Abhi 1 month pahle bor karwaya jo 80 feet se kam pipe dale hai aur moter 70 feet me latki hai pani ke sath mitti ati kya salution h iska kya pipe aur dalay????
@@Easy_fit naa bhai jab bhi monsoon ka session aata hai tb ye problem ata hai ek baar ganda pani ata hai feer problem chaalu ho jata hai.. ampere dhire dhire kam hone lagta hai or paani kam dene lagti hai motor
Hum log ke yaha par water level upar rahta hai isiliye mera 25 feet borring kiya hua hai or single jet pump laga hua hai,pahle paani bhout tej aata tha par ab bhout slow aata hai ab kiya kare??
Hlo bhai mera bore ko 2 saal se upar ho gya h lekin 20-25 min se jyada chalane se thoda ganda pani aata hai .Bore k casing me 30 se 50 feet tak kuch kuch hole kiya gaya h.aisa kyun ho raha hai & iska solution kya h.garmi k mahine me accha pani aata h bas halka sa ret rehta h.
@@rishi2275 wo halka halka har kisi ke borewell se nikalta hai aap kisi ke bhi water tank me dekhiye ha neeche mithi jami rehti hai wo borewell se hi aata hai
Sir maine new summer sebile lagaya hai kal vo 10 sec paani aata hai fir band ho jaata hai fir band karna padta hai dwara se chalu karo to fir 10 sec deta hai maine summer ko 55 foot par daala hai paani us jagah par 30 foot par available hai aur borring 60 foot ka hai me bahut pareshaan hu
@@himanshuyadav1510 pipe ko kuch feet upper kar dijiye or phir bhi na thik ho tab barsath ke bad 2nd casin pipe dalwana hoga 1st wale casin pipe ke andar
हम आपकी समस्या समझ सकते है ऐसा होने के पीछे का कारण केसिंग पाइप का फट जाना या सही से पाइप ना लगाने से होता हैं अगर ऐसा है तो आपको एक साइज का का पाइप वापस डालना पड़े गा
सर हम 155 फिट boring करवाया और उसमे grebull nhi गया जिसके कारण पानी ganda de रहा tha phi हम ne 100 फिट collam pipe se 70fit kar diya fir bhi pani Ganda de रहा है please solution sir बताए
फिलहाल अभी मैं उस बोर में LUBI का 1 hp टुलु पंप use कर रहा हूं 2 इंच सेक्सन पाइप 30 फिट नीचे तक डाला गया है कंटीन्यू 8 घंटे तक चलाया हु। तो ऐसे में Texmo 3 hp 4 स्टेज v6 लगा सकता हूं या नही plz भैया बताइए
Sir ji Namaste.. Sir humne bor krwaya hi jisme 55 fit me pani agya hi joki borwell 180 fit last hova hi. Ap btiye ki pump hm konsa lgwaye kitne stage ka & pump ko kitne fit tak rakhna sahi hoga plz btiyega
Sir humne summersible pump 1.5 hp ka dala hai or bore 300 feet karwaya hai. pani 120 par hai or humne pump 130 par bhi rakh kar dekh lia or 270 feet pr bhi rakh kr dekh lia pressure nhi aaraha or pani bhi 1se 2 min aata hai or woh bhi ganda plz replyy
Hamare bore well m bhi Ganda pani aa raha h abhi 1 months pahle flashing phir se karvae kuch din saaf aya pani ab phir se Ganda pani aa raha h koi solution batao please
Mera jo borewell ha 24 days huya....but ab v jab 1st time pame calate hu..1st time fress water a ta ha then ghola wala pati a ta ha 2 minute then fresh water a ta hay....a kiq ho raka ra...plz reply?????????
@@sancharislifestylediary9114 hota hai normal hai par kuch din me thik ho jayega or phir bhi thik nahi hota hai to submersible ko upper kar dijiye 30-50 feet
Sir mera summersible ko 6 saal hogaye piche kuch saalo se pani kam der tak chalne laga hai ab to 5 minute chal raha hai full pressure fir bar bar low fast horaha hai kya problem hoga
Bhai mene abhi bor karvaya he par paani rukruk kar aatahe kya Karu Paani,110fit par he Or kolam 18 kolam dadihe 10fit ki 1he 230 fit borhe Paani pahle 1મિનિટ aatahe fir 3sec ru kar aatahe 10"kaborhe Kya karna chahiye ૯૦૨૩૭૪૨૨૬૧
@@SHRAVANKUMAR-jp9kp 1.5 21 stage ya 20 stage ka submersible aap lga sakte hai par 7-8 min hi chalega or band ho jayega Par use karte rehte se kismat acha raha to bad me dheere dheere pani badhega !!!
Total borewell 240 feet Pani 70 feet me Submersible 120 feet me Agar starter se koi technical problem nahi ho raha hai to Or submersible 10 stage se upper ka hai to 210 feet me submersible ko lga ke dekhiye
Motor jyada power ka dal dene se ya jyada niche pump dal dene se bhi aisa hota hai Baki borewell casing pipe sahi se fit nhi ho ga to usme me dikkat hota hai flash karana padta hai nhi to agar pipe fata ho ga to eke out size kam ka pipe dalwana pade ga bahut se karan hote hai
Yeah problem nahi hai bhai jaise jaise borewell me pani niche jayega waise waise pressure bhi kum hoga Phir wait kijiye wapas pani upper aayega to phir se waise pressure se pani dega 👍👍👍
@@Jh.Edu24 aapka bolna sahi hai par submersible ka kaam suck karna bhi pani ko upper lift karna hota hai Esliye jitna upper me pani hoga speed bhi utna hoga
Sir namaste sir hamane 5 din pahale new boring kar wai hai 120.fet par machin 60.feet ke neche nahi ja rahi hai .kiya kare bahut koshish ki hai paani 30 feet par lag gaya tha
Borewell.. 730feet Motor level.. 380feet.. 3hp.. 23stage.. 1hour.. Water pressure high After 1hour.. Pressure becomes low Motor off.. On for 3minutes.. Water comes high pressure.... Whats the reason.. Silt blocking the extra filter mesh? Or water source less?? Please reply...
Sir mera motor 70 feet mein fas gaya haii usko kaise bahar nikala jaay... Uppar se koi gitti daal diyaaa 1 gamla . Baaki bhaiya 1 hp ki motor haii 200 feet borewell haii 140 tak casing daala huwaa haii agar koi karta hai toh bataye jo v kharch h hum pay karenge.. Or ha paani abhi 1 saal ho gye haii paani saaf h
Aquatex texmo vs taro texmo konsa accha hai doono me se v3 pump 160 borwell ke liye ...
@@Shaksagar tero texmo best hai
sir agar koi jali na lagaye to problem hoga kya
No
(Mera matlab company se liye Jane wali jail se tha ) hamare new Burwell mein pump dal ke Chala rahe hai to usme niche se ret ka blockage ar hai aur ret pump ko jam kar De raha hai agar koi solution ho to please bata dijiye🙏🙏
@@rohankanu9880 company ke sath jo jali mila hai jarur use karne
Submersible ko lagane se pehle borewell me chips ( giti ) dhal dete tab neeche ganda upper nhi aa pata
@@Easy_fit sir hamare mistri ne galti kiya hai🥲🥲 thank you reply karne k liye🙏🙏🙏
Sir 2hp borwell ki moter me konsa capiciter lagaye 125 fit se pani utane ke liye 200+ voltages hai
Water cool hai to 72 ka runing stating 150/200
Oil cool hai to 60 ka runing stating 120/150
@@Easy_fit Thenks sir
Sir 150 ft borewell ke liye kitna hp pump use kare?
Aur kitna ft pump fit kare?
@@sarvashreenaik2359 1 hp 10 stage 120-130 feet me pump ko rakhiye
Double filter pipe kaise lagaya jata ek par ek vedio banaye
Ok 👍
India mark handpump mein suction pipe ki jagah filter pipe with jali lga sakte hai
Nhi mujhe nhi lagta
@@Easy_fit kisi engineer se baat karke clear kre
Maine nahi lagaya bhai
Or aap Konsa pipe ki baat kar rahi hai pehle clear honge tab na pipe ki category and size kya hai ?
@@Easy_fit cylinder ke neeche false pipe ki 1.25 inch
Bhai ...abhi nya borewell kraya h 270 ft tk casing pipe h jisme 6 filter pipe h aur motor 230 ft me h 5 din ho gye balu aa rhi ret aur kali balu ....iska kya solution h ??? ....jldi btana bhai
Submersible ko upper 200 feet me rakh ke dekhiye kuch din !
@@Easy_fit column pipe 20 hi pade the pahle motor c.r.i. ka h 1.5hp/15 stages ka h pani ka flow km aa rha tha to 3 pipe badhaye h ...jisse abhi flow to accha aa rha h bs kali balu aur ret aa rhi
Sir abhi 4 din pahle bor karwaya hai 180 fit aur chalu krte hai to pahle saf pani ayega 1 min tak fir ganda ane lgta hai aur 1 min bad fir se saf pani dene lgta hai
@@Sangeetavlog88 avi barish ke mahine me hoga par dheere dheere sahi ho jata hai use karte rehne se
@@Easy_fitkitne dino mao pani saaf ho jata h?
@@Deepak-mk5ne Maxx to maxx 1 week normal ganda pani aa raha barish ke karan
Bai thada chalne per pump balluu koi Dene lagta hai
@@MohdArif-yw6qe halke me to aayega bhai jee
Thanks you
Sir ji hamare aria m pani 120 feet par pani ganda aa raha pani peela ho jata h matila
Plz help m kiya karen ....
Iron wale type ka pani aata hai ??
Ye jo pani chal rha ye kitna inch pani he
1 inch
300 ft पे कौन सी मोटर और कितने HP का लगाए, साथ ही साथ अच्छा pipe kaun से लगाए
@@आशित-पटेल Konsa Konsa brads ke submersible available hai aapke area me
@@Easy_fit Crompton, हैवल्स,
घर के लिए लगवाना है
@@आशित-पटेल crompton love jiye 1.5 hp 15 stage water cool or 12.5 kg pressure wala 1.25 inch colum pumps rakhsh ya ashirwad and cri
@@Easy_fit बहुत बहुत धन्यवाद, आपका
600 feet 6 inch borewell k lia konsa pump acha hai?
Single phase line me ya three phase lines me ???
Namaste bhaiya mera borewell 8 month purana hai starting se hee isme see patla ret aata hai aur kabhi kabhi yellow mitti bhi aati hai
@@snraiarmybholenathjii6994 kitna feet ka borewell hai and kitna feet me submersible install hai
330fit borewell hai aur vo kitne pr install Kiya hai nahi pata bhaiya
@@snraiarmybholenathjii6994 ok 20 feet pipe kum kar dijiye
Thank u bhaiya
3 hp single phase 350 ft me dalna hai texmo pump dalnese acha chalega kaya pilz buliye voltage 220 hai
haa dal sakte hain par texmo thoda voltage mangta hain
Hmne borewell 300 feet ka karwaya hai ... jisme 110 feet casing pipe Dali hai...pani 90 feet me aa gya tha.... submersible pump lgaane pr usme ret aa gyi or vo chalna bnd ho gyaa ...humse pump nikaal ke safai kewai or upr se net baabdh ke fr pump dala ...kuch der pani aane ke baad fr pani aana bndho gya ..kya krna chahiye
Mtlb bar bar submersible ka pump jaam ho raha hai
Eska Mtlb borewell wale me acha se flashing nahi kiya hai
@@Easy_fit sir ab iska kya solution hai
@@anmolchawla8080 borewell wale ko bol ke ache se flashing karwana hoga warna baar baar pareshaan rahiye ha
Or galti se casin pipe creak huwa hoga to or problem ho sakta hai
Bhai maine 18 mahine pehle summer sabil lgwaya tha 230 ft
Shuru ke 6 months me use 4-5 baar hi chlaya pr pichle ek saal se daily chl raha h phir bhi usme barik reta aa raha h
15 minutes chlaenge to usme 5-6 minutes reta aata h
Kya iska koi solution h
Kitne feet ki borewell h aur kitne hp ka pump h
Sir mere borewell m ganda pani aa rha hai 2 - 3 din se and 2 - 3 minutes ke bad pani dena band kar deta hai... Or borewell purana hai chapakal ko hata kr usme submersible pump dale hai... Ky karan ho skta hai sir plz reply jrur kare
Hand pump kholne ke karan aa raha hai kuch din me sahi ho jaye ga
@@Easy_fit Sir hand pump khole bhut sal ho gya hai.. Borewell m sirf submersible pump dala hua hai
@@SURAJMURMU-q5p submersible ko 30 feet upper kar dijiye sahi ho jana chahie kuch din me
Ksb 1.5 hp 8 stage with starter ka kya price hoga Approx
17000
@@Easy_fit price only pump ka hai yah pump with starter ka hai
??
With starter
120 fit ma kon sa submersible motor Lagana chahie
1 hp 10 stage 13500 submersible + starter CRI water cool
Sir please please help me🙏🏻..
Sir ek saal pehle maine 250feet boring karwaya thha..185feet mai pani aaya thha..casing 89feet tak hai..1hp ka submerssible motar lagwaye thhe...1 saal achchha pani diya...,,..1 saal chalne ke baad motar kharab ho gaya tow..naya motar lagaye...2024 mai....abhi naya motar lagane ke baad 5 se 6 minute pani dene ke (200 litter pani aata hai)..baad Pressure ekdam down ho jata hai..please 🙏🏻..sir bataye isme motar ki kharabi hai ya..borewell mai pani kam ho gaya hai..??...bahat paresan hu..sir..please reply kare🙏🏻
Sir 3hp motar me delivery pipe pressure ke liye matter karti hai jaise delivery pipe 3 ki hai usko 2.5 ka hona chahiye
Ji bilkul
Abhi 1 month pahle bor karwaya jo 80 feet se kam pipe dale hai aur moter 70 feet me latki hai pani ke sath mitti ati kya salution h iska kya pipe aur dalay????
Total borewell kitna tha ??
80 feet pipe dale 15 feet kaccha kiya
@@mryash1435 boring ka total gahrai kitna tha ???
95 feet
Motor lagane se pehle borewell ko nape the ho sake to 95 feet se kum ho gya ho ??? Ek bar motor nikal ke borewell ko nap lijiye patli rassi ki help se
Submersible me thoda sa ganda paani aata hai or pressure kam ho jata hai uska kya karn ho sakta hai....
Pump me bori bhi bandh kar dale the kya
@@Easy_fit naa bhai jab bhi monsoon ka session aata hai tb ye problem ata hai ek baar ganda pani ata hai feer problem chaalu ho jata hai.. ampere dhire dhire kam hone lagta hai or paani kam dene lagti hai motor
Kuchh din pehle motor k bussing bhi nayi dlavayi hai ... motor pump me emplier to nhi ghees chuke honge...?
@@DJNrv wo to nikal ke dekhna hota hai
Bai mere Borewell se pain saaf aa Raha hai lemon ov 6 hours me baad Ganda ho jarha hai suburban daale 1 year hogye
Kitne dino se ?
Sir 110 feet par mere aria m pani ganda pila aa raha h kiya karen
Hum log ke yaha par water level upar rahta hai isiliye mera 25 feet borring kiya hua hai or single jet pump laga hua hai,pahle paani bhout tej aata tha par ab bhout slow aata hai ab kiya kare??
@@munnabarnwal jet pump ka impeller ko check karwaiye
@Easy_fit motor sahi hai qki rrc water tank ko hum khud motor laga ke khali kiye the aaram se ho gaya
Sir borewell se limca type pani aa raha hai
@@MoZaid-zr5gc chatan mila hoga borewell me Esliye thik ho jayega
Bhai 300 fit bor hai 2.5 inchi aaya hai konsi moter dale or hp please 🥺
Ghar ke liye ya kheti ke liye???
@@Easy_fit kheti ke liye
Three phase line use karte hai ya single phase???
@@Easy_fit 3 phase
Bore me pani ka levale kesa badaye video pls
Ok 👍
@@Easy_fitSir aap se ek baat puchna tha..
0.5 hp ki water moter se 30ft jamin ke andar se pani nikal sakate hai please jawab jarur dena sir
@@KomalKomal-hs8ks kaun sa motor hai
0.5 ki moter hai or hamara borewell 30 ft ka hai moter borewell ke bhar rakhne wala hai to is se pani aayega
@@KomalKomal-hs8ks submersible na laga ke tulllu pump lga dijiye 25 feet kaam karta hai
2 hp sumbersever bore main dali hai 150 feet bore h 100 feet pipe dala hai par pressure nhi de rha hai
Alag alag v series ka video banayee
Jarur bhai sahab
Nice information
Hlo bhai mera bore ko 2 saal se upar ho gya h lekin 20-25 min se jyada chalane se thoda ganda pani aata hai .Bore k casing me 30 se 50 feet tak kuch kuch hole kiya gaya h.aisa kyun ho raha hai & iska solution kya h.garmi k mahine me accha pani aata h bas halka sa ret rehta h.
@@rishi2275 wo halka halka har kisi ke borewell se nikalta hai aap kisi ke bhi water tank me dekhiye ha neeche mithi jami rehti hai wo borewell se hi aata hai
@@Easy_fitsirf 20-25 min tak halka ret aata h uske baad se ganda pani suru ho jata hai.iska kya karan ho skta h?
Sir maine new summer sebile lagaya hai kal vo 10 sec paani aata hai fir band ho jaata hai fir band karna padta hai dwara se chalu karo to fir 10 sec deta hai maine summer ko 55 foot par daala hai paani us jagah par 30 foot par available hai aur borring 60 foot ka hai me bahut pareshaan hu
Kitna amp le raha hai ?
mera bhi yehi problem tha
Same problem. Kya solution hai iska
Kitne hp ka submersible hai or kitna Amp le rahi hai submersible?
Sir mera boring 2saal phle hua hai 300 feet par abhi 1 mahine se matti colour pani aaya rha hai
Motor 90 feet par hai kaise thik kare plz help
Casin pipe kitna feet takk hai ?
@@Easy_fit 290 feet
Sir compressor chalwa laye ya phir rhne de
@@himanshuyadav1510 pipe ko kuch feet upper kar dijiye or phir bhi na thik ho tab barsath ke bad 2nd casin pipe dalwana hoga 1st wale casin pipe ke andar
Bhai summersubile mere 350 feet hain motor 150feet per hain koy fayada nhi pipe extend karwana se
Phir apke casing pipe me problem ho skta hai
@@Easy_fit any solution
@@Easy_fit ye mechanic samj nhi aarha 10 minutes saaf pani for baaalu ka pani or uska baad pura ballu miithi mithi kyu
हम आपकी समस्या समझ सकते है ऐसा होने के पीछे का कारण केसिंग पाइप का फट जाना या सही से पाइप ना लगाने से होता हैं अगर ऐसा है तो आपको एक साइज का का पाइप वापस डालना पड़े गा
@@Easy_fit ek size ka pipe waps mtlb kya huha kitna pasia lag jaye ga approxx
Siva kIsa pipe h reply dejyi plz
Use nahi kiye hai bhai
Borewell flush mein kitna cost aata hai ...Mera 450 feat new borewell hai jisko flush karwana hai
New borewell me jo lga hai uska 50% lagta hai
Mera borwell mai Pani se sand aati hai jo ki pump jaam kerti hai.
Sand ko kaise roka jaskta hai.pls reply
@@Suhailwanie kuch feet submersible ko upper kijiye
सर हम 155 फिट boring करवाया और उसमे grebull nhi गया जिसके कारण पानी ganda de रहा tha phi हम ne 100 फिट collam pipe se 70fit kar diya fir bhi pani Ganda de रहा है please solution sir बताए
Casin pipe kitna feet takk hai ?
7"केसिंग पाइप,270 फिट पे पानी आया था टोटल गहराई 400 फिट वाटर लेवल 14 फिट है( बोर में पानी 3 इंच) क्या मैं Taro texmo 3hp 4स्टेज v6 लगा सकता हूँ।
Yea
फिलहाल अभी मैं उस बोर में LUBI का 1 hp टुलु पंप use कर रहा हूं 2 इंच सेक्सन पाइप 30 फिट नीचे तक डाला गया है कंटीन्यू 8 घंटे तक चलाया हु। तो ऐसे में Texmo 3 hp 4 स्टेज v6 लगा सकता हूं या नही plz भैया बताइए
@@AbhishekKumar-yi9ww 8 ghante har bar chalta hai ya kewal ek bar hi chalaye hai ???
हर बार चलता है
कभी 2 घंटे कभी 6 घंटे कभी 8 घंटे लगातार 1 मंथ से ऐसे ही चल रहा है भैया
Bhai asirvad company ka borwells casine pipe kitne kitne kg me market me aata ? please btaye
humlog to 350 per feet dalte hai 12kg wala
Sir ji Namaste..
Sir humne bor krwaya hi jisme 55 fit me pani agya hi joki borwell 180 fit last hova hi. Ap btiye ki pump hm konsa lgwaye kitne stage ka & pump ko kitne fit tak rakhna sahi hoga plz btiyega
Ghar ka use hai to hain to 1hp 10stage le lijiye kirloskar company me
@@Easy_fit kitne fit tak best rahega sir pump ko le jana last 180 fit hi & cri pump kesa hi sir
150 feet pe rakhiye CRI se achha kirloskar rhe ga ya varuna
@@Easy_fit hello sir.. Humne kiloskar 1hp 8 stage ka pump liya hi sir cabel wire 1.5 mm ka diya hi shop wale ne..
@@prakashvaidya5526 10 stage lete kum se kum
Sir 🙏 Humne bhi borvel karaya hai 15 din ho gaye lekin Pani ganda hi Samajh Mein Nahin a Raha Kya Karen please please help me
Submersible 20 feet upper kar dijiye
Barish hone k baad pani ganda aane lagta hai iska koii solution hai
Yeah chiz khudh se thik ho jayega
Sir humne summersible pump 1.5 hp ka dala hai or bore 300 feet karwaya hai. pani 120 par hai or humne pump 130 par bhi rakh kar dekh lia or 270 feet pr bhi rakh kr dekh lia pressure nhi aaraha or pani bhi 1se 2 min aata hai or woh bhi ganda plz replyy
Kitna stage ka pump hai aur voltage kaisa hai
@@Easy_fit15 stages or voltage bhi 220 h
Hamare bore well m bhi Ganda pani aa raha h abhi 1 months pahle flashing phir se karvae kuch din saaf aya pani ab phir se Ganda pani aa raha h koi solution batao please
1st step 20 feet submersible ko upper kijiye
Phir bhi na ho to next step bta dunga
Ye bhi ker diya h
40 feet upper ker diya h
@@sumeshthakur4192 ab 2-3 din use kijiye time to time saf ho jayega
Bhaiya pani bahut jada pani de raha he to kam kese kre kam ya jada hota he kyaa
Nahi bhai agar ball valve lga rokne ki kosis kijiye ga to motor kharab ho jayegaa
Phle b bor krwaya 280 feet an 2 months bd 2sri bar 280 feet boring kreaya hai pani saf ata hai but smell boht ati hai gutter ki
Agar bagal ganda pani jamta hoga wo bhi aapke borewell me effect karega
2 jaga py aise hoskta hai same? Or ye smell kabi nai jaygi kya?
@@gulandam1865 casin bna ke dhalwane se sahi ho sakta hai
@@Easy_fit wo kya hota hai
@@gulandam1865 filter wala casin pipe hota hai wo use karna hota hai agar pani gand ya smell karta hai to
200 feet boaring ke liye kon sa pump le
1hp 13stage cri 12.5 kg pressure coloum pipe
Filter with jali>cylinder>column pipe in india mark handpump?
Sir mera boring ka pani 100 liter ke baad ganda pila pani aane lagta hai koi upaye hai iska
Borewell me filter nahi hai sirf 100 feet 3 inch pipe hai
Bleaching powder and alum ka powder bna ke dal dijiye raat me
Mera jo borewell ha 24 days huya....but ab v jab 1st time pame calate hu..1st time fress water a ta ha then ghola wala pati a ta ha 2 minute then fresh water a ta hay....a kiq ho raka ra...plz reply?????????
@@sancharislifestylediary9114 hota hai normal hai par kuch din me thik ho jayega or phir bhi thik nahi hota hai to submersible ko upper kar dijiye 30-50 feet
500ft ka bor chalega 2hp single fash motor mai
humne 2hp 600 feet me dala hai plus 200 feet door pani use pump se bheja bhi hai aapko vo video dekhni chahiye
Sir 1 saal ho gya sambarsivail karwaya tha sir ab tkk pani saaf nhi hua tank main mitti ho jate hai 10 din main he
Kitna feet borewell hai aur pump kitne feet pe hai
15 ampiyar le rhi h pani nhi a rha h kya kare 60 feet me dala h.
Kitna hp hai
@@Easy_fit 1hp
Voltage kitna ata h load dene k bad
Bhai mere bor se ret nikalti h aur pankhi jaam ho jati h motor kharab ho jate h kya karu
Kitne feet ka bore h pump kitne feet par h aur kitne hp ka h
@@Easy_fit 300ft h 150 me dala h 3hp h
Submersible ko bahar nikaliye or borewell flash karwaiye
@@Easy_fit kitna kharcha aata h flash krane me kaun karta h
भाई प्रेशर मेरे पास 1.5 HP मोटर 20 मिनट बाद कम हो रहा है, क्या करें,
1/2 inch pani mila hoga borewell me Esliye
Pani k level Kam hai 180 fit me kya kare?
Kam power ka pump sahi rhe ga
Sir mera summersible ko 6 saal hogaye piche kuch saalo se pani kam der tak chalne laga hai ab to 5 minute chal raha hai full pressure fir bar bar low fast horaha hai kya problem hoga
Boosh ya bearing change hoga
Or ek baar running capacitor ko change kar dijiye
Bhai mene abhi bor karvaya he par paani rukruk kar aatahe kya Karu
Paani,110fit par he
Or kolam 18 kolam dadihe 10fit ki 1he
230 fit borhe
Paani pahle 1મિનિટ aatahe fir 3sec ru kar aatahe
10"kaborhe
Kya karna chahiye
૯૦૨૩૭૪૨૨૬૧
Submersible machine hai compressor machine ???
Ha
Lubi 20hp
Bhai hamara moter pani bahut kam de raha hai
Suru se ya kuch min chalne ke bad ??
@@Easy_fitkuch minutes chalane ke baad. Aur tanki me mitti+Balu v aata hai
@@MITHUAMIT submersible ko upper kar dijiye
Bhai mera boring 520 ft hai aur Pani 360 per hai to motor Kitna andar Tak dalen jisse Pani theek thak de
Avi jameen ki satah se jitna neeche pani hai ???
Boring ke samay thoda sa bhi Pani nahi nikala tha aur aaj check kar rahe the to 360 ft niche Hai Pani Aaj boring ka ek saptah ho chuka hai
Jameen se 160 ft upar tak he pani hai
@@SHRAVANKUMAR-jp9kp 1.5 21 stage ya 20 stage ka submersible aap lga sakte hai par 7-8 min hi chalega or band ho jayega
Par use karte rehte se kismat acha raha to bad me dheere dheere pani badhega !!!
240 fit me paani 70 pr hai Par Pani 1 ya 2 minut main aana Band ho raha hai 120 fit pr motore daal di hai tab bhi
Total borewell 240 feet
Pani 70 feet me
Submersible 120 feet me
Agar starter se koi technical problem nahi ho raha hai to
Or submersible 10 stage se upper ka hai to 210 feet me submersible ko lga ke dekhiye
Please apna no de dijiye,mere yaha boaring me Ganda Pani aa raha hai, please no. Dijiye
AAP mujhe Instagram me msg kijiye
@@Easy_fitsolutions to btao pani mein meethi ret arha bilkul clean Pani kyo ni ho rha
Motor jyada power ka dal dene se ya jyada niche pump dal dene se bhi aisa hota hai
Baki borewell casing pipe sahi se fit nhi ho ga to usme me dikkat hota hai flash karana padta hai nhi to agar pipe fata ho ga to eke out size kam ka pipe dalwana pade ga bahut se karan hote hai
@@Easy_fit bhai mere to shuru se hi kbi ajtk iska pani mein ret ana band hua ni km hojata lekin bilkul ana band ni ho rha ret 🤔
Hamara bhi low pressure ho raha hai.. Or baat mai automatic band ho jata hai
Motor ON karne ke bad speed se aati hogi na uske bad pressure low ho ke band ho jaa rahi hoga ??
भाई presure 20 minute चलने के बाद प्रेशर कम हो जाता है
Yeah problem nahi hai bhai jaise jaise borewell me pani niche jayega waise waise pressure bhi kum hoga
Phir wait kijiye wapas pani upper aayega to phir se waise pressure se pani dega 👍👍👍
@@Easy_fit पर भाई मोटर तो नीचे ही न लगा है
@@Jh.Edu24 aapka bolna sahi hai par submersible ka kaam suck karna bhi pani ko upper lift karna hota hai
Esliye jitna upper me pani hoga speed bhi utna hoga
Bhai Mera borewell bhut Ganda Pani aur Kam pressure deta hai solution plz 😢😢
Jab motor on karte hai tab se hi hota hai ya kuch der sahi aata hai uske bad aisa ho raha hai
30 sec min sahi phir slow ho jata hai @@Easy_fit
@@aqibkhan6487 borewell me pani ka short acha nahi hoga Esliye borewell dry ho jaa raha hai
Sir namaste sir hamane 5 din pahale new boring kar wai hai 120.fet par machin 60.feet ke neche nahi ja rahi hai .kiya kare bahut koshish ki hai paani 30 feet par lag gaya tha
@@vikeshudhwani6889 kitna inch ka borewell hai and kitna inch ka casin pipe lga hai or submersible v4 hai ya v3 hai ?
Borewell.. 730feet
Motor level.. 380feet..
3hp.. 23stage..
1hour.. Water pressure high
After 1hour.. Pressure becomes low
Motor off.. On for 3minutes..
Water comes high pressure.... Whats the reason..
Silt blocking the extra filter mesh?
Or water source less??
Please reply...
Pani ke sath baalu ke kan aaa rahe hai kya ???
V4 ka video
@@MukeshKumar-h1x7e v4 ka bahot sari video hai aap check kar sakte hai
Sir mera motor 70 feet mein fas gaya haii usko kaise bahar nikala jaay... Uppar se koi gitti daal diyaaa 1 gamla . Baaki bhaiya 1 hp ki motor haii 200 feet borewell haii 140 tak casing daala huwaa haii agar koi karta hai toh bataye jo v kharch h hum pay karenge.. Or ha paani abhi 1 saal ho gye haii paani saaf h
Kaha ka problem hai bhaiya
@@Easy_fit ye ramgarh jharkhand
@@Easy_fit paani abhi saaf aata haii... But jo summersible hai wo 70 feet mein koi gitti daal diyaa haii
@@Easy_fit bhaiyaa koi karta haii toh bataye
@@Easy_fitaap koi upaaye batao.. Consultation fee aapko denge.. Same as doctor fee you deserve it
Sir help me
Boliye
मोटर चालू करने के बाद एपीअर का काटा निचे क्यो आता है.
Pani kum hona to niche aayega
@@Easy_fit धन्यवाद.
@@Easy_fitmltb😮??
Motor pe jitna load ho ga utna hi ampere le ga
@@Easy_fit meethi kyo ni khtm ho rhi ye btao pani bilkul clean kyo ni ata usme.thodi thodi meeti ati h 🧐🤔
Barish hone ke bad pani gnda aata hai
Hota hai kuch Din ke liye
@@Easy_fit jab jab barish hogi tab tab khrab hoga iska koi upay hai
@movieclip855 hota hi hai jyda se jyda yahi kar sakte hai submersible ko kuch feet upper kar dijiye
Mera ek saal ho gaya ganda Pani aa raha hai
@@SukhuKindo-iv6mu tab aap borewell me 2nd casin pipe chalwa dijiye
Same question h
चलते चलते बंद हो जाता है
@@ganeshtelami kitna time me bad ho jaa raha hai acha hoga aap Instagram me video bna ke bhejiye taki mai ache se samjh saku
Sir please reply me
Boliye
Sir aap contact no dejeye na pls...
6201150992
Aap ka contact number chahiye
Instagram me msg kijiye mil jayega
Aapka contact number dijiye sir aapse baat karni hai
About me hai