مرحباً هل يمكنك ان تشرح عن طرق الاختبار الانفرتر مثلا ماهوو الباور سبلاي عند التجريب عبر مدخل الالواح او مدخل البطاريات. مثلا اذا الانفرتر يحتاج مدخل الالواح اقل شيئ 150 فولت كم فولت أعطية وامبير من الباور سبلاي ام هناك طرق اخرى للاختبار
Hi could you please assist me here my solar inverter does not show the panels icon so apparently the batteries are not charging, what could be the problem and what's the solution ?🙏🏽
Hello dear, in my solar power plant the voltage readings of the batteries differ, on the batteries and in the inverter, for example on the inverter 51.1 volts and at the same time on the batteries 53.3 volts, please tell me what is the reason. I changed the wires to a cross-section of 35 squares, but there was no change. The multimeter is working fine, but I can’t understand the reason. And my batteries are balanced with bluetooth, which shows what is in the multimeter. Thank you in advance for your answer.
Million thanks brother for your great efforts and useful videos
Really good video and nice to see a repair on this type of inverter
Nice video, thanks!
Many thanks for the video, may can you assist me in case the insulation between main board and case are not 0L, which point should I check to replace?
السلام عليكم،فينا نشيل pure sine wave conductor عن البورد ،ونحطو على الهيكل؟.بسبب حرارتو المرتفعة وتأثيرو على عناصر البورد .
Is membership available i want to join your channel
مرحباً هل يمكنك ان تشرح عن طرق الاختبار الانفرتر مثلا ماهوو الباور سبلاي عند التجريب عبر مدخل الالواح او مدخل البطاريات. مثلا اذا الانفرتر يحتاج مدخل الالواح اقل شيئ 150 فولت كم فولت أعطية وامبير من الباور سبلاي ام هناك طرق اخرى للاختبار
Hi could you please assist me here my solar inverter does not show the panels icon so apparently the batteries are not charging, what could be the problem and what's the solution ?🙏🏽
good for ur repairing..but deye compny is worst as reaping in system......many boards are like third class fitting.
Sir invartar drive igpt ka pahle point par 6.9 volt or 3point par 6.3volt baki sab par 6.6volt a rahe ha igbt install kar do
Hello dear, in my solar power plant the voltage readings of the batteries differ, on the batteries and in the inverter, for example on the inverter 51.1 volts and at the same time on the batteries 53.3 volts, please tell me what is the reason.
I changed the wires to a cross-section of 35 squares, but there was no change.
The multimeter is working fine, but I can’t understand the reason.
And my batteries are balanced with bluetooth, which shows what is in the multimeter.
Thank you in advance for your answer.
Check dc wires length -&+ the same length?
..
Check dc breaker if you have a one
Measurement before the dc breaker and after it
Must be the same
Everything you said is normal.
Is it possible that the problem is in the control board?@@ALayoubiMaintenanceCenter
Hola, si me uno al grupo obtengo asistencia via whatsapp? gracias
i am waiting your new video
hello sir how are you sir i ask him this inverter is a comon fault more here plz reply the deye inverters and how to solve fault🎉🎉🎉🎉🎉
👍👍👍👍
👍
asalamoalikom
Hello happy new year, I sent you a query via wp