How to Install a Roof Drain

Поділитися
Вставка
  • Опубліковано 5 жов 2016
  • Learn how to properly install a roof drain. We will tell you what materials you need and a step by step process to successfully install a commercial roof drain!

КОМЕНТАРІ • 22

  • @garrett3113
    @garrett3113 6 років тому

    I just learned a bit more about drains now. But we usually use new products after tear off so all things i will use to my knowlegde. Thanks to this video also.

  • @OSCARSanchez-lf7qv
    @OSCARSanchez-lf7qv 7 років тому

    very well explained detail.

  • @stevecase4592
    @stevecase4592 4 роки тому

    grea video... Love the work shoes

  • @mululife1
    @mululife1 7 років тому

    Thank you.

  • @ZURITROY13
    @ZURITROY13 2 роки тому

    Very good. We’ll explain 👌.

  • @angelderas5853
    @angelderas5853 5 років тому +1

    Nice i do it all the time am a Roofer

  • @robgallegos9303
    @robgallegos9303 3 роки тому +5

    Why he cut the tpo ??? Just need to replace the metal ring !!

  • @ZURITROY13
    @ZURITROY13 2 роки тому

    Nice 👍

  • @detumaki
    @detumaki 7 років тому +1

    my only problem is the exposed edge of the iso. many manufacturers will require seperator sheets or the paper face be there as it can prematurely age and damage tpo and pvc membranes. beyond that, i like it. though IBC12 requires the minimum hole cut in the flashing be 4" or the size of the pipe, whichever is bigger.

  • @juanvilchis6178
    @juanvilchis6178 2 роки тому

    Exelente

  • @mahtabali7833
    @mahtabali7833 3 роки тому

    can you share with me material detail

  • @ivanibarra6542
    @ivanibarra6542 6 років тому +1

    Is this for all roofing systems or just some I’m very confused I’ve been roofing for 2 years and I’ve never seen and unsupported patch installed on drains

    • @Moises-kf1hg
      @Moises-kf1hg 6 років тому

      in 2 years you didn't learn that unsupported comes in 2' rolls? At the 3 minute mark, you can see his measurement for the patch is 35"

    • @feligarcia130
      @feligarcia130 5 років тому +2

      And it’s not unsupported that’s actual field membrane cut into a target for the drain

  • @rikkkardodavid7137
    @rikkkardodavid7137 5 років тому +5

    I hate the look of a circled target. We aleays do them squared.

  • @WaIIyMaven
    @WaIIyMaven 3 роки тому +1

    No drain sump, that's not ideal, but interesting. I believe a general guideline is to keep the center hole at least an inch smaller in diameter than the drain pipe itself while maintaining a 1" minimum amount of PVC inside the drain bolts.
    Flat and wide drain hubs are also better

  • @glennlathem9772
    @glennlathem9772 5 років тому +2

    Damn some roofing company don't know what water block is for.

  • @janchristiansen4865
    @janchristiansen4865 5 років тому

    is this something from the stone age i only remove them and install new and better ons

    • @WaIIyMaven
      @WaIIyMaven 3 роки тому

      Looks like a drain Hub from a previous SBS or BUR roof.