your explanation is up to the mark, excellent, clear understanding of the concept. Please make a video on the substation automation protocol IEC61850. there is no good explanation video on this topic. thank you so much.
sir i'm a b.tech student nad mene bahut machine study ki hai but yesa pratical knowladge mujhe aj tak kisi se nhi mila i'm so big thankful for u sir...........
Ab Smjh Mein Aaya Ki Ghar Mein Load Increase Karna Ho To Govt. Electrical Department Ko Kyu BataYa Jata Hai Thank You Sir This Video Is Very Informative For Experience Holder's
Abhishek Sir Please Indian standard codes pr bhi video banaye aur standard ke according explain kare ki kaise koi bhi work hum Indian electrical standard ke according krwa shkte hai jisme aao earthing work cable laying termination, transformer erection installation ko smjhaye
Sir maine elecctrician ko bol kr tap change krwaya tha kyonki phele voltage badhane k liye but kuch mahine baad voltage phir se low ho gya please bataye kyo???
sir let voltage ratio 10:1.. primary voltage is 10V and secondary voltage is 1V..also primary turns is 10 and secondary turns is 1.. now if we increase tap therefore no. of turns is 11 therefore secondary voltage is 10/11 which means on increasing tap.. voltage decrease which is doubt?
Sir number of turns badhta hai to voltege increase hoti hai ..Thik hai Jab 66kv/11kv ka transformer hai ..Matlb stap down transformer hai . Agar mujhe LV side ka voltage ko 10.5kv ho gya hai . Mujhe 11kv karna hai. Mins uska numbers of turns badhane padenge . Jo ki impossible nhi hai. Qki taping HV side hui hai..To hum kewal HV side ka hi numbers of turns ko change kar sakte hai.. To agar mujhe 10.5 kv ko 11kv karna hai to LV side ka numbers of turns badhane ke liye hume HV side ka numbers of turns Dcriese karna padega n..Qki HV side ka humber of turns ko hum Dcriese karenge to Automatically LV side ka numbers of turns jayada ho jayega...Qki LV side ki wainding constent hai n... Please reply me sir . Mai dout me hu..Aap ka video dekha kar .. Please
Jo banda apke sare videos dekh le...wo electrical engg banke rahega.. love 💕 from UK
your explanation is up to the mark, excellent, clear understanding of the concept. Please make a video on the substation automation protocol IEC61850. there is no good explanation video on this topic. thank you so much.
The way of your explanation is too good sir, thank you so much, God bless you and your family forever 🙏🙏🙏
ua-cam.com/users/shortsLvvPzRL0J1A?feature=share
sir i'm a b.tech student nad mene bahut machine study ki hai but yesa pratical knowladge mujhe aj tak kisi se nhi mila i'm so big thankful for u sir...........
Most welcome Tanuj..
Ab Smjh Mein Aaya Ki Ghar Mein Load Increase Karna Ho To Govt. Electrical Department Ko Kyu BataYa Jata Hai
Thank You Sir
This Video Is Very Informative For Experience Holder's
Thanks a lot. It’s a really helpful information. Your teaching quality is easy to understand.
Thank you sir ,🌹🌹🙏🙏
Good explanation . My request is to please mention or display the picture to understand theriticaly and Practicaly. Thanks
U are one of the best in UA-cam bro for general concept of electrical explanation
Nice Explain SirJi🙏
Sir मैं आप का सारा वीडियो देखता हु मैं भी elecrician हु ucil mines मे
One of the best teaching I ever seen
Very nice and helpful information sir
So easy to understand🙏great content and explanations ❤
Wonderful way of describing this Topic. 👍👍
Finally I found Someone from industry
Site bahot hi achha samjate hai verry good sir thank so math
Thanks sir mai aap ko follow karta hu
Sir ❤❤ App ka samjane tharika bahuth ach he
Sir Apke video se hme kafi help milta hai
Thank you sir
Most welcome Vivek..
Excellent explanation . Thank you sir.
Great video sir. Can you please explain about Automatic on load tap changer as well
I love you transition effect
Mirror no-mirror mirror no-mirror👌
And love you videos too very useful.
Very Informative Topic👍
ua-cam.com/users/shortsLvvPzRL0J1A?feature=share
Excellent Presentation.
Very useful information
Very nicely explained sir, thank you.
Sir video on testing and commissioning of transformer pleas.
Great sir
Best explanation ❤🎉
Now it is crystal clear.. 😁😁 thank you 🙏
Such a informative bideo
Sir, topic on saturable reactor Kay bare mei jana hai...
Jaise koi stepup transformer like 11/132kv to bhi high voltage side hi lgega??
Very nice sir thank you
Good sir mujhe cable ki load ratting ka knowledge chaiye
Very informative video sir. Thank you.💖
sir OLTC ka principle details vdo banaye.
Very useful information.. Thanks!
Adha chapter complete ho gya broo😂😊
Wow excellent explanation 🥲
Thank u so much😊
Very good explanation sir,
Explained good
❤ love you brother .
Tysm sir very easy explanation
Abhishek Sir
Please Indian standard codes pr bhi video banaye aur standard ke according explain kare ki kaise koi bhi work hum Indian electrical standard ke according krwa shkte hai jisme aao earthing work cable laying termination, transformer erection installation ko smjhaye
Full of knowledge vedio sir thank you
ua-cam.com/users/shortsLvvPzRL0J1A?feature=share
Thank you very much for Quality information.pls make video based on transformer, motor and P.F. Questions ( numerical)
Nice information sir ..with soft ..nice to hear ..
Useful
Video
Sir pls make a video on generator protections
Thank you so much very good explanation
सर आपका एक्सप्लेशन बहुत ही अच्छा है but ak suggestion है आप जिस भी टॉपिक पे वीडियो बनाए उसका पिक्चर भी एडिट करे अंडरस्टैंडिंग और क्लियर होगी व्यूवर की
I like it very much 👍👌🌹🇵🇰🇵🇰
Excellent
How to work Automatic tap Changer panel....how to sence voltage...?
Thanku u so much sir
Greatest sir
Thank you so much sir for your knowledge sharing....
jaddu kardi bhai
Sir maine elecctrician ko bol kr tap change krwaya tha kyonki phele voltage badhane k liye but kuch mahine baad voltage phir se low ho gya please bataye kyo???
explained to be Practically & its PM..
Shooting video in plant or office is against the protocol.
Great 👍
Hamare substation mai bhi 10 MvA Power Transformer hai , usko bhi ham On load Tap changing karte hai , as demand of Output Voltage
Sandaar
Maine like pehle hi kar fiya
Thanks..
Fantastic
Superb explain sir 👍
We can regulate to a voltage in secondary side of a transformer is also known as tap changer
Thank you sir
Pura doubt clear
Nice sir
Your all videos are superb...👍👍
Thank you Vijay...
Good
Kindly make video on PT in Switch gear and control trafi
Great
Nice explanation clear voice bro
Thank you Alisha..
Hv winding ka temperature lv k comparison Q zayada hota hai sir please answer.....????
ONLOAD Tap changers operates Manually or Automatically?
Can we raise the voltage during under voltage incoming supply?
Super sir
Thank u so much sir for your guidance
Sir what is the safety of OLTC someone asked to me during interview
What is RTCC(remote tap changer)?
Sir iska maintenance kese karte hai plz plz sir woh bhi banao🙏🙏🙏
Thank you so much sir 🙏❤
Sir kotputli se birla factory 🥰🥰🥰🥰cement
sir let voltage ratio 10:1.. primary voltage is 10V and secondary voltage is 1V..also primary turns is 10 and secondary turns is 1.. now if we increase tap therefore no. of turns is 11 therefore secondary voltage is 10/11 which means on increasing tap.. voltage decrease which is doubt?
Eamxactly.You have to decrease the number of turns on the primary side to increase the secondary voltage...
Any decrease in the number of turns in the primary side will increase the volts per turn ratio, thus increasing the secondary voltage.
The way of explanation is so good but sir but i cant understand please repeat this topic
Very good
Thank you Surendra...
Excellent sir
Thanks bhai
Kudos
Step up trafo me tap changer secondary side ya primary side hota h , please bataye
Abhishek bhai plz talk about incomer trolly service and there wiring connection
Excellent explanation 😊
Sir, please make videos about transformer testing.
Great Explanation 👑
Sir number of turns badhta hai to voltege increase hoti hai ..Thik hai
Jab 66kv/11kv ka transformer hai ..Matlb stap down transformer hai . Agar mujhe LV side ka voltage ko 10.5kv ho gya hai . Mujhe 11kv karna hai. Mins uska numbers of turns badhane padenge . Jo ki impossible nhi hai. Qki taping HV side hui hai..To hum kewal HV side ka hi numbers of turns ko change kar sakte hai..
To agar mujhe 10.5 kv ko 11kv karna hai to LV side ka numbers of turns badhane ke liye hume HV side ka numbers of turns Dcriese karna padega n..Qki HV side ka humber of turns ko hum Dcriese karenge to Automatically LV side ka numbers of turns jayada ho jayega...Qki LV side ki wainding constent hai n...
Please reply me sir . Mai dout me hu..Aap ka video dekha kar .. Please