Siemens S7 1200 "Modbus RTU" Sinamics V20 VFD

Поділитися
Вставка
  • Опубліковано 31 гру 2024

КОМЕНТАРІ • 34

  • @chandrajput9006
    @chandrajput9006 2 роки тому +2

    Not only show
    You will explain every point and every block of this program

  • @Kazimroza4u
    @Kazimroza4u 5 місяців тому +1

    Hi i am having two v20 drives connected to cpu 1214. They are running in auto mode with analog input controlling frequency. Also the inverters are connected to cpu thru modbus. Currently i had a drive issue and replaced with new drive. Now the drive is running but the rpm, current data not coming in cpu. Kindly guide

  • @imedtools9256
    @imedtools9256 4 дні тому

    how to calculate the adresse 1151 of forward run ??

  • @ΑγγελοςΔημογλου-π7ι
    @ΑγγελοςΔημογλου-π7ι 11 місяців тому

    i followed exactly your video and i still have no connection from my rs485 leds are off....i used both channel 10 and 11 to try modbus rtu connection but no connection
    do i miss something thats not on the video?

  • @strat_egi
    @strat_egi 10 місяців тому

    I wanted to use your guide for setting up the device. but unfortunately it does not have such parameters. how to find them? Unfortunately I can’t configure it through macros. sinamics v20 fsc

  • @ahmedsami2270
    @ahmedsami2270 Рік тому

    How to cancel the negative sign, as the speed value appears on the inverter screen as negative؟

  • @uditsaxena3844
    @uditsaxena3844 Місяць тому

    Please explain how you got this number1151 and 3199 in your network 4 branch

  • @devendrachowdary2333
    @devendrachowdary2333 8 місяців тому

    I have a doubt how can we assume and add those numbers to control word to control on and off or rev or fwd .i didn't see those numbers in manual
    Can you explain me sir

  • @syedyasirhussain9302
    @syedyasirhussain9302 Рік тому

    Do you have video on S7 200 & Micromaster 420 USS Protocol communication?

  • @ajaydumka731
    @ajaydumka731 Рік тому

    Thank for such a informatic video. I want a solution , after setting all parameters in sinamic v20 the drive frequency limited to 22.74 hz only . As i already provide min and max frequency. Please help

  • @rubentjuuu
    @rubentjuuu 6 місяців тому

    I'm using CB 1241 - 6ES7241-1CH30-1XB0 (rs485 module) but cannot get the communication to work using this tutorial. please help

  • @murilohenriquepereira9771
    @murilohenriquepereira9771 2 роки тому

    Goodnight! to make modbus communication with several inverters in cascade as you would indicate?

  • @global-tech3203
    @global-tech3203 Рік тому

    Hello dear I got a fault 8180 on my master bloc or my id port is correct. Could you please helping me ??

  • @adolfoleonhernandezabadia5360
    @adolfoleonhernandezabadia5360 2 роки тому

    Mucho gusto, una consulta referente al modulo RTU, que referencia tiene Industry Mall, muchas gracias.

  • @caonhumr4751
    @caonhumr4751 6 місяців тому

    How to read faults via plc modbusRTU?

  • @DomenicoMadeo
    @DomenicoMadeo Рік тому

    hello, if I change the frequency and it doesn't change on the v20 do I have a problem with communication? how can i check this?

    • @global-tech3203
      @global-tech3203 Рік тому

      P1000 in you vfd must 5 for frequency control in modbus

  • @logicmindautomation1458
    @logicmindautomation1458 Рік тому

    Hi, can you show your wiring on the plc from the drive?

  • @timschulle8238
    @timschulle8238 Рік тому

    Can you make a video where you control the v20 with codesys? For Example with a Raspberry Pi. I am trying to control a v20 with modbus in codesys but i dont get the fault. I dont know what i did wrong. The videos with Siemens software exists often, but nowhere i found one with Codesys to control the v20.
    Thanks :)

  • @mohammedrezk8072
    @mohammedrezk8072 Рік тому

    why we use max for the scale o/p 16384 ?

  • @OOOMuhammadSyahrulKhoiri
    @OOOMuhammadSyahrulKhoiri 5 місяців тому

    can you give me the program please? i cant download from your website sir

  • @josepintoferreira5454
    @josepintoferreira5454 Рік тому

    vc pode enviar o projeto para o tia portal

  • @MehediHasan-es5et
    @MehediHasan-es5et 2 роки тому

    + Set Word 40100 = 1151 >>> Forward Run
    = 3199 >>> Reverse Run. How about 1151 & 3199, could you explain Please?

    • @henriqueteixeira1236
      @henriqueteixeira1236 Рік тому

      Please go to the article to read the details

    • @global-tech3203
      @global-tech3203 Рік тому

      1151 and 3199 there are hexadécimal code they was convert in décimal

  • @ronnelelpa6878
    @ronnelelpa6878 Рік тому

    Make.a tutorial using factory Io..pick and place using analog signal

  • @josepintoferreira5454
    @josepintoferreira5454 Рік тому

    como baixar o projeto gostei muito

  • @joeltshiela4605
    @joeltshiela4605 3 місяці тому

    👍

  • @reduanchowdhury7810
    @reduanchowdhury7810 3 місяці тому

    Bro I worked more than 12 hours on your project but not successful please help me

  • @Scheme_Match
    @Scheme_Match Рік тому

    #plc247Automation Sir I need to talk. How can i contact you