Hi i am having two v20 drives connected to cpu 1214. They are running in auto mode with analog input controlling frequency. Also the inverters are connected to cpu thru modbus. Currently i had a drive issue and replaced with new drive. Now the drive is running but the rpm, current data not coming in cpu. Kindly guide
i followed exactly your video and i still have no connection from my rs485 leds are off....i used both channel 10 and 11 to try modbus rtu connection but no connection do i miss something thats not on the video?
I wanted to use your guide for setting up the device. but unfortunately it does not have such parameters. how to find them? Unfortunately I can’t configure it through macros. sinamics v20 fsc
I have a doubt how can we assume and add those numbers to control word to control on and off or rev or fwd .i didn't see those numbers in manual Can you explain me sir
Thank for such a informatic video. I want a solution , after setting all parameters in sinamic v20 the drive frequency limited to 22.74 hz only . As i already provide min and max frequency. Please help
Can you make a video where you control the v20 with codesys? For Example with a Raspberry Pi. I am trying to control a v20 with modbus in codesys but i dont get the fault. I dont know what i did wrong. The videos with Siemens software exists often, but nowhere i found one with Codesys to control the v20. Thanks :)
Not only show
You will explain every point and every block of this program
Please go to the article to read the details
Hi i am having two v20 drives connected to cpu 1214. They are running in auto mode with analog input controlling frequency. Also the inverters are connected to cpu thru modbus. Currently i had a drive issue and replaced with new drive. Now the drive is running but the rpm, current data not coming in cpu. Kindly guide
how to calculate the adresse 1151 of forward run ??
i followed exactly your video and i still have no connection from my rs485 leds are off....i used both channel 10 and 11 to try modbus rtu connection but no connection
do i miss something thats not on the video?
I wanted to use your guide for setting up the device. but unfortunately it does not have such parameters. how to find them? Unfortunately I can’t configure it through macros. sinamics v20 fsc
How to cancel the negative sign, as the speed value appears on the inverter screen as negative؟
Please explain how you got this number1151 and 3199 in your network 4 branch
I have a doubt how can we assume and add those numbers to control word to control on and off or rev or fwd .i didn't see those numbers in manual
Can you explain me sir
Do you have video on S7 200 & Micromaster 420 USS Protocol communication?
Thank for such a informatic video. I want a solution , after setting all parameters in sinamic v20 the drive frequency limited to 22.74 hz only . As i already provide min and max frequency. Please help
I'm using CB 1241 - 6ES7241-1CH30-1XB0 (rs485 module) but cannot get the communication to work using this tutorial. please help
Goodnight! to make modbus communication with several inverters in cascade as you would indicate?
Hello dear I got a fault 8180 on my master bloc or my id port is correct. Could you please helping me ??
Mucho gusto, una consulta referente al modulo RTU, que referencia tiene Industry Mall, muchas gracias.
How to read faults via plc modbusRTU?
hello, if I change the frequency and it doesn't change on the v20 do I have a problem with communication? how can i check this?
P1000 in you vfd must 5 for frequency control in modbus
Hi, can you show your wiring on the plc from the drive?
go to my website sir
Can you make a video where you control the v20 with codesys? For Example with a Raspberry Pi. I am trying to control a v20 with modbus in codesys but i dont get the fault. I dont know what i did wrong. The videos with Siemens software exists often, but nowhere i found one with Codesys to control the v20.
Thanks :)
why we use max for the scale o/p 16384 ?
Sinamics V20 stipulates so
@@plc247automation6 sorry i don't understand what you mean
can you give me the program please? i cant download from your website sir
vc pode enviar o projeto para o tia portal
+ Set Word 40100 = 1151 >>> Forward Run
= 3199 >>> Reverse Run. How about 1151 & 3199, could you explain Please?
Please go to the article to read the details
1151 and 3199 there are hexadécimal code they was convert in décimal
Make.a tutorial using factory Io..pick and place using analog signal
como baixar o projeto gostei muito
👍
Bro I worked more than 12 hours on your project but not successful please help me
#plc247Automation Sir I need to talk. How can i contact you