I see a lack of knowledge regarding how is working the substructure. 1. Most of the anchors for the brackets were installed between the bricks ( this means the pullout capacity is compromised) 2. All brackets are working like fixed support for the T profile. This is totally wrong. There is thermal expansion and also building slab movements. Usually, the top brackets are fixed with circular holes and all other brackets below have to be with vertically orientated slotted holes. This video can be used for "Typical mistakes in installation of ventilated facade system"
We have tested the chemichal fixation and you have to understand that the majority of the curtain walls have mechanichal fixation too. We also prefer a double fixation (mechanichal and chemichal) but the Architecht prefer this option.
This installation appears to be a bad idea to use regular batt insulation... I would have used a rigid type poly-iso foam board (dark colored) ... This type of board is waterproof and will not harm the performance of the insulation... they will regret this decision when the batt insulation starts sagging within the cavity.
Thank you for your comment, we happen to agree. Although, according to the adhesive manufactures, it is an adequate fastening element for this type of application, they guarantee its suitability by carrying out behavioral tests against the wind. It is a valid and safe fastening system, although some regulations may exist, depending on each country, that for building works that exceed 3 m. a double fixation method, chemical and mechanical, will be necessary as an extra safety element.
sorry but this system is total bullshit and shitty to mount 2:52 WTF 2:58 WTF????? Ensave Group, Hilti or Systea have far more better solutions with a double bracket
Это можно сделать намного дешевле, поставить туры с механическим механизмом раздвижные или ряд подмостей выставить, обращайтесь к нам за каркасом optima-fasad.ru/informatsiya/tekhnologiya-montazha-sistemy.html
QUE MARCA DE SILICONA Y CINTA DOBLE RECOMIENDA PARA LA INSTALACION
what happens to the water that goes behind the panels and reach the insulation?
Nice 👍🏻 work good job
I see a lack of knowledge regarding how is working the substructure.
1. Most of the anchors for the brackets were installed between the bricks ( this means the pullout capacity is compromised)
2. All brackets are working like fixed support for the T profile. This is totally wrong. There is thermal expansion and also building slab movements. Usually, the top brackets are fixed with circular holes and all other brackets below have to be with vertically orientated slotted holes.
This video can be used for "Typical mistakes in installation of ventilated facade system"
Hi sir ...Can you help me to know how i install it very well with mesure ? thank You.
Люлка хорошая,где такой найти? Подскажите...
На нашем сайте у вас есть информация о компании: www.levantina.com/russia/. Спасибо!
What if the adhesive fails due to weathering after time?? I prefer to have a mechanical connection.
We have tested the chemichal fixation and you have to understand that the majority of the curtain walls have mechanichal fixation too. We also prefer a double fixation (mechanichal and chemichal) but the Architecht prefer this option.
adhesive has ETA Approval
injektorofficial Yes of couse
Could u make long video....it's very short description..... although it's really good
Hello Mitesh, if you have any questions, you can send us an email to info@levantina.com and we will be happy to help you. All the best.
How to mould the Techlam ?
With a cnc cutting machine
the adhesive has been tested in controlled circumstances for weathering and aging. it is also warrantied
Of course we test it and the give the warranty!!
@@eduaguilobalet9258 is it waterproof?
I probably shouldn't use it since we get rain here.
This installation appears to be a bad idea to use regular batt insulation... I would have used a rigid type poly-iso foam board (dark colored) ... This type of board is waterproof and will not harm the performance of the insulation... they will regret this decision when the batt insulation starts sagging within the cavity.
Bagus bngt Chanel nya
does not look secure / panels need a combination of mechanical and adhesive fixing
Thank you for your comment, we happen to agree. Although, according to the adhesive manufactures, it is an adequate fastening element for this type of application, they guarantee its suitability by carrying out behavioral tests against the wind. It is a valid and safe fastening system, although some regulations may exist, depending on each country, that for building works that exceed 3 m. a double fixation method, chemical and mechanical, will be necessary as an extra safety element.
This system is great and fast as well
But not suitable for UK or country's with similar weather i think
Otherwise its really good
My opinion
We have many available solutions (www.sistemamasa.com), we can offer you a mechanichal system as well
Prem vishwakarma
These cladding type are failing a lot in the uk
Ropeman 100 Maybe are not well installed
sorry but this system is total bullshit and shitty to mount 2:52 WTF 2:58 WTF????? Ensave Group, Hilti or Systea have far more better solutions with a double bracket
so good
Thank u!!
Hlo
Это можно сделать намного дешевле, поставить туры с механическим механизмом раздвижные или ряд подмостей выставить, обращайтесь к нам за каркасом optima-fasad.ru/informatsiya/tekhnologiya-montazha-sistemy.html
fouad