BUCEO 𝐑𝐄𝐁𝐑𝐄𝐀𝐓𝐇𝐄𝐑 - 𝐇𝐎𝐖 𝐈𝐓 𝐖𝐎𝐑𝐊𝐒 COMO FUNCIONA UN REBREATHER 𝐒𝐈𝐌𝐏𝐋𝐄 𝒔𝒖𝒃𝒕𝒊𝒕𝒍𝒆𝒔 𝒂𝒍𝒍 𝒍𝒂𝒏𝒈𝒖𝒂𝒈𝒆𝒔 𝓫𝔂 𝓹𝓮𝓵𝓪

Поділитися
Вставка
  • Опубліковано 5 вер 2024
  • If you want to see this video 𝒔𝒖𝒃𝒕𝒊𝒕𝒍𝒆𝒔 𝒊𝒏 𝑬𝒏𝒈𝒍𝒊𝒔𝒉 𝒐𝒓 𝒂𝒏𝒐𝒕𝒉𝒆𝒓 𝒍𝒂𝒏𝒈𝒖𝒂𝒈𝒆 , remember to click on the configuration wheel below, subtitles, automatic translate, choose language, and voila, you can read it in your own language.
    𝐑𝐄𝐁𝐑𝐄𝐀𝐓𝐇𝐄𝐑 - 𝐇𝐎𝐖 𝐈𝐓 𝐖𝐎𝐑𝐊𝐒 - 𝐅𝐔𝐍𝐂𝐈𝐎𝐍𝐀𝐌𝐈𝐄𝐍𝐓𝐎 𝐏𝐀𝐒𝐎 𝐀 𝐏𝐀𝐒𝐎 𝐒𝐈𝐌𝐏𝐋𝐄 𝒔𝒖𝒃𝒕𝒊𝒕𝒍𝒆𝒔 𝒂𝒍𝒍 𝒍𝒂𝒏𝒈𝒖𝒂𝒈𝒆𝒔 ....𝓫𝔂 𝓹𝓮𝓵𝓪
    𝐑𝐄𝐁𝐑𝐄𝐀𝐓𝐇𝐄𝐑 𝐄𝐀𝐒𝐘 𝐒𝐓𝐄𝐏 𝐁𝐘 𝐒𝐓𝐄𝐏 𝐎𝐏𝐄𝐑𝐀𝐓𝐈𝐎𝐍 ....𝓫𝔂 𝓹𝓮𝓵𝓪
    𝐂𝐎𝐑𝐑𝐄𝐂𝐂𝐈𝐎𝐍: 𝐃𝐎𝐍𝐃𝐄 𝐒𝐄 𝐃𝐈𝐂𝐄 𝐀𝐈𝐑𝐄 𝐂𝐎𝐑𝐑𝐄𝐒𝐏𝐎𝐍𝐃𝐄 𝐆𝐀𝐒 ...𝐃𝐈𝐒𝐂𝐔𝐋𝐏𝐀𝐒 ...𝓫𝔂 𝓹𝓮𝓵𝓪
    EN EL GRAFICO USTED PUEDE VER Y ENTENDER DE LA SIGUIENTE MANERA.
    IN THE GRAPHIC YOU CAN SEE AND UNDERSTAND IN THE FOLLOWING WAY
    1- BOQUILLA EN LA BOCA SUPERFICIE-BUCEO ACTIVAR PALANCA.
    1- MOUTHPIECE IN THE MOUTH SURFACE-DIVING ACTIVATE LEVER.
    2- INHALO DEL CONTRAPULMÓN GAS FRESCO PROVENIENTE DE LA SALIDA DEL CANISTER.
    2- INHALE OF THE FRESH GAS COUNTERPULMON FROM THE CANISTER EXIT.
    3- EXHALO Y EL GAS CON CO2 VA AL CONTRAPULMÓN DE EXHALACIÓN, EN EL CUAL HAY UNA TRAMPA DE AGUA, DEBIDO A LA HUMEDAD DE LA EXPIRACIÓN Y OTROS, ESTA GUA ACUMULADA LA PUEDO DESECHAR CON VÁLVULA MANUAL DE O2 O AUTOMÁTICA.
    3- EXHALE AND THE GAS WITH CO2 GOES TO THE EXHALATION COUNTER-LUNG, IN WHICH THERE IS A WATER TRAP, DUE TO THE MOISTURE OF THE EXPIRATION AND OTHERS, THIS ACCUMULATED GUIDE CAN BE DISPOSED WITH A MANUAL O2 VALVE OR AUTOMATIC.
    4- CONTINUA EL GAS CON CO2 AL CANISTER Y PASA POR EL SCRUBBER DONDE ESTA LA CAL SODADA QUE ABSORBE EL CO2, CONTINUA POR EL CIRCUITO Y ES CONTROLADO A TRAVÉS DE LOS SENSORES DE OXIGENO QUE ACTIVAN LAS VÁLVULAS SOLENOIDES PARA SU INYECCIÓN AL LOOP PREVIO ANÁLISIS DE LA PPO2 QUE ES INDICADA EN LOS DISPLAY DE MUÑECA.
    4- CONTINUES THE GAS WITH CO2 TO THE CANISTER AND GOES THROUGH THE SCRUBBER WHERE THE SODIUM LIME THAT ABSORBS THE CO2 IS, CONTINUES THROUGH THE CIRCUIT AND IS CONTROLLED THROUGH THE OXYGEN SENSORS THAT ACTIVATE THE SOLENOID VALVES FOR INJECTION TO THE PRE-ANALYSIS LOOP OF THE PPO2 THAT IS INDICATED IN THE WRIST DISPLAY.
    5- CIERRA EL CIRCUITO CON EL GAS PARA SER RESPIRADO.
    5- CLOSE THE CIRCUIT WITH THE GAS TO BE BREATHED.
    6- A MEDIDA QUE VAMOS TOMANDO PROFUNDIDAD LA VÁLVULA AUTOMÁTICA DEL DILUYENTE COMPENSA VOLUMEN.
    6- AS WE GO TAKING DEPTH THE AUTOMATIC VALVE OF THE THINNER COMPENSATES VOLUME.
    7-AL ASCENDER VÁLVULA DE SOBREPRESIÓN EXPULSA GAS.
    7-WHEN ASCENDING OVERPRESSURE VALVE EXPULSES GAS.
    8- HAY SENSORES DE PRESIÓN Y TEMPERATURA, LOS CUALES CONTROLAN LA PRESIÓN DEL CONTRAPULMÓN Y LA TEMPERATURA QUE PUEDE MANIFESTARSE EN EL SCRUBBER E IR AL LOOP.
    8- THERE ARE PRESSURE AND TEMPERATURE SENSORS, WHICH CONTROL THE PRESSURE OF THE COUNTER-LUNG AND THE TEMPERATURE THAT CAN BE MANIFESTED IN THE SCRUBBER AND GO TO THE LOOP.
    9-LAS DOS UNIDADES DE CONTROL TESTEAN EL LOOP, TODO EL TIEMPO, EN CASO DE FALLAR UNA TOMA EL MANDO LA RESTANTE, EN CADA UNA HAY CONECTADO DOS SENSORES DE OXIGENO Y UNO DE PORCENTUAL DE HELIO O DILUYENTE, CADA UNIDAD DE CONTROL TIENE SU PROPIA BATERÍA DE ALIMENTACIÓN.
    9-THE TWO CONTROL UNITS TEST THE LOOP, ALL THE TIME, IN CASE OF FAILING ONE TAKE THE REMOTE CONTROL, IN EACH ONE TWO OXYGEN SENSORS ARE CONNECTED AND ONE PERCENTAGE OF HELIUM OR THINNER, EACH CONTROL UNIT HAS ITS OWN POWER BATTERY.
    10- EL HEAD UP DISPLAY SON 3 LUCES PARPADEANTES CONECTADAS A LOS SENSORES MEDIANTE FIBRA ÓPTICA, QUE NOS INDICAN PPO2, BUENA LUZ VERDE, MAL LUZ ROJA.
    10- THE HEAD UP DISPLAY ARE 3 FLASHING LIGHTS CONNECTED TO THE SENSORS THROUGH OPTICAL FIBER, WHICH INDICATE US PPO2, GOOD GREEN LIGHT, BAD RED LIGHT.
    11- TANTO EL DILUYENTE COMO EL CILINDRO DE OXIGENO TIENEN VÁLVULAS MANUALES DE ADICIÓN.
    11- BOTH THE THINNER AND THE OXYGEN CYLINDER HAVE MANUAL ADDITION VALVES.
    12- CADA CILINDRO TIENE SU VÁLVULA DE APERTURA-CIERRE PRINCIPAL, CADA REGULADOR CONECTADO TIENE DIFERENTES PASOS DE ROSCA Y MANÓMETRO.
    12- EACH CYLINDER HAS ITS MAIN OPENING-CLOSING VALVE, EACH CONNECTED REGULATOR HAS DIFFERENT THREAD STEPS AND GAUGE.
    13- CUANDO INHALAMOS SE ABRE VÁLVULA DE INHALACIÓN EN LA BOQUILLA, Y ESTA CERRADA LA DE EXHALACIÓN, LO CONTRARIO AL EXHALAR, CON ESTO EVITAMOS QUE EL GAS RETORNE EN SENTIDO INVERSO, SIEMPRE TIENE UN SOLO SENTIDO, Y SE EVITA CONTAMINAR EL GAS FRESCO.
    13- WHEN INHALING, THE INHALATION VALVE IS OPENED IN THE NOZZLE, AND THE EXHALATION VALVE IS CLOSED, THE OPPOSITE OF EXHALING, WITH THIS WE AVOID THAT THE GAS RETURNS IN A REVERSE SENSE, ALWAYS HAS A SINGLE SENSE, AND AVOID CONTAMINATING GAS.
    CICLO COMPLETO.
    COMPLETE CYCLE.
    IF YOU HAVE ANY DOUBT, CHECK WITH YOUR INSTRUCTOR OF YOUR DIVING SCHOOL.
    🅢🅘🅔🅜🅟🅡🅔 🅒🅞🅝🅢🅤🅛🅣🅔 🅐 🅢🅤 🅘🅝🅢🅣🅡🅤🅒🅣🅞🅡...🅑🅨 🅟🅔🅛🅐
    ȺNŦɆ ȻᵾȺŁꝖᵾƗɆɌ ĐᵾĐȺ SƗɆMⱣɌɆ ȻØNSᵾŁŦɆ ȺŁ ƗNSŦɌᵾȻŦØɌ ĐɆ Sᵾ ɆSȻᵾɆŁȺ.
    .....................𝓫𝔂 𝓹𝓮𝓵𝓪
    𝐏𝐄𝐋𝐀-𝐭𝐢𝐩𝐬 𝟑𝟒𝟎 𝐩𝐮𝐧𝐭𝐨𝐬 𝐝𝐞 𝐛𝐮𝐜𝐞𝐨 𝐞𝐧 𝟐𝟒 𝐩𝐚í𝐬𝐞𝐬 𝐲 𝟗𝟎 𝐬𝐢𝐭𝐢𝐨𝐬 𝐝𝐢𝐟𝐞𝐫𝐞𝐧𝐭𝐞𝐬...𝖇𝖞 𝖕𝖊𝖑𝖆 link
    www.google.com...
    marinelli naomi jorge claypole salta
    .............................𝖇𝖞 𝖕𝖊𝖑𝖆
    #pela_team #PELAtips #bypela

КОМЕНТАРІ • 3

  • @kevin0225emi
    @kevin0225emi 3 роки тому

    Eccellente spiegazione!!

    • @by_pela
      @by_pela  3 роки тому

      Grazie amico....𝒃𝒚 𝒑𝒆𝒍𝒂

  • @by_pela
    @by_pela  4 роки тому

    𝐂𝐎𝐑𝐑𝐄𝐂𝐂𝐈𝐎𝐍: 𝐃𝐎𝐍𝐃𝐄 𝐒𝐄 𝐃𝐈𝐂𝐄 "𝐀𝐈𝐑𝐄" 𝐂𝐎𝐑𝐑𝐄𝐒𝐏𝐎𝐍𝐃𝐄 "𝐆𝐀𝐒" ...𝐃𝐈𝐒𝐂𝐔𝐋𝐏𝐀𝐒 ...𝓫𝔂 𝓹𝓮𝓵𝓪