Hello sir. I want to ask you some questions for transmission pump working pressure low? How to make sure for this problems ??? Can you advice to me ? Thanks 😊
Hello to sir, the first step, check level oil transmission and filter Transmission(good condition) and then makesure all system Hydraulic Transmission not leaking oil, then check Transmission main oil pressure at port control valve ( approximately 1,7 Mpa or 17kg/cm2) for solenoid electrical mustby standby power 24 Volt DC
Bang mau tanya,,saya ada XCMG LW300F.. alat ini begitu terkena beban,, transmisi & Torque Converter menjadi Panas hingga 120° solusi nya bagaimana bang.. mohon bantuan nya..
Mantap Sekali Brother, Overhaul Powertrain nya.. Semoga lancar Prosesnya 🙏
Aamiin Saudara...siappp laksanakan
Muy buena su enseñanza maestro y muy cactada bendiciones dede ecuador un abrazo ala distancia maedtros
Lanjut...Go Tractors Que
Semangat & selalu hati2 kaka🤝👍
Semoga sukses dan sehat selalu sodaraku aamiin
Aamiin...Barakhallahu fii umrik Saudara...Semoga Diberi Yang Terbaik Oleh Allah SWT Aamiin...
Semangat brother ku... Ttp jaga kesehatan
Siapp Brother...Mauliate Godang
Mau tanya kakak. Kalo Inlet pressure tidak ada apakah powershift nya bisa masuk gigi?
I need information about the XCMG ZL50G WHEEL LOADER SPARE PARTS GEARBOX Transmission assembly
ZF 4WG200 Bukan?
Olá você teria manual serviço da lw300kv sou brasileiro
Karobkani 3marota yigdik ozroq yuradi tabloda yana datchik yondi nima wilgan
Hello sir. I want to ask you some questions for transmission pump working pressure low? How to make sure for this problems ??? Can you advice to me ? Thanks 😊
Hello to sir, the first step, check level oil transmission and filter Transmission(good condition) and then makesure all system Hydraulic Transmission not leaking oil, then check Transmission main oil pressure at port control valve ( approximately 1,7 Mpa or 17kg/cm2) for solenoid electrical mustby standby power 24 Volt DC
Javob bersa buldinmi
Bang mau tanya,,saya ada XCMG LW300F.. alat ini begitu terkena beban,, transmisi & Torque Converter menjadi Panas hingga 120° solusi nya bagaimana bang.. mohon bantuan nya..
Periksa cooler Transmisi Bang...apakah dalam kondisi bagus(tidak tersumbat)..Thanks
Bang mau nanya bg,kalau pemasangan torque converter tidak merata gimana solusi nya bg?
Harus rata Bang, karena bisa menyebabkan putaran bergetar, Harus buka dan ratakan Bang...Thanks
Shift lrvrr
Ichida 3dona vali yiyilib ketayapdi
Mau tanya kalo gigi mundurnya nnga masuk itu apanya ya...
Bisa electrik bisa pressure Bang
@@GoTractors elektrik suda saya periksa ada....arusnya masuk ke silinoid bang..🙏🙏
Kalau electrik bagus, berarti hydraulic transmisi yang harus diperiksa, apakah control valve yg masalah atau piston yg didalam transmisi bocor
@@GoTractors iya bang transmisi suda saya kasi turun....tapi kontrol Valve blom saya pariksa....mohon petunjuk bang🙏🙏🙏
Pastikan gak ada spool yang stuck dan mulus..lihat saja divideo Bang..dan cari di youtube² lain Bang yg bongkar control valve grader