Bhai itna galti mut kiya karo. jo galti hota hai us cien ko cut kar diya karo phir se dubara video bana kar usse sett kardiya karo. Or apka har videos mjhe aacha lagta hai ...👍
Sir aapki bhut si vedios Maine dekhi h bhut behtrin andaz me samjhate h ap aapki hi ek vedios dekhi thi jisme btay the ki condenser ke shell side me refrigerant aur tube side me water, evaporator/chiller ke shell side me water aur tube side me refrigerant hota h , but aapne yaha dono me same bata rahe h
Ji ha York chiller me condenser and evaporater me same tarah hota hai ... Qki york chiller ke evaporater fluded typ evaporater hai.... Fluded typ evaporater me 👉tube me water and shell me gas hoti hai And DX typ evaporater me tube me gas and shell me water hota hai
Reciprocating ya centrifugal compressor me oil kaise change karte hai ustime me kon kon SA tools use karte hai Pura complete ek video banaye oil Ka temperature Kiya Hota hai
Centrifugal compressor jo use hota h vo high ton ke plant ke liye use hota hena like 400tr se upr jab jata h tab ????? Nd dosra ye bataiye sir ki Compressor ka capacity kaise decide hota h ? As per ton yah kuch or Same waise hi mujhe puchna h pump se related uska hp capacity kaise lete h as per ton yah as per heat load calculation I know questions bhut sare ho gye but aap short me bata do Yaah is par koi video bana do sir please Compressor Pump Nd also cooling tower ka sabke capacity kaise niaklate yah pata krte h .agr koi project plan chilled water ka like 1000 tr ka Agr kise ne pucha ki is plan me Compressor cooling tower pump ka kya capacity h toh kaise me bataun ? Without looking machine i hope aap samjh gye honge question sir Please sir 🙏
Sir ek BAAT aur bataye agar ek chiller me tin ya char centrifugal compressor laga hua hai aur usme se ek me koi problem hogaya jisko maintenance Karna Hoga to us situation me Kiya krege chiller ko off Karke maintenance Hoga ya chiller chaltarahega aur uska maintenance Hoga ye questions mujhse client pucha hai
Aap chiller chala sakte hai ۔۔koi problem nahi hai qki har compresser ki alag alag circuit bani hoti hai ۔۔۔bas dhayan rahe ki full shafty ke sath agar running chiller pe work kare to sukriya
Cooling tower me water level ok rakho .. qki jab cooling tower me water level kam ho jata hai to air suck karne lagta hai jiski vajah se .. aise alarm aate hai ...
@@c4chiller9984 Temperature set point is at 9°C and the capacity set point is at 80%. the Chiller does not obey the set points. If I increase the capacity, after the ramp, it goes to 105% and I fell. I'm here on the other side of the world 😀 Brazil. I'm waiting for help 👍 and thank you for your attention!
Sir vedio fir se bnaaye please zara slow or derail mm explain kijye please .... Please .... Please.... Bahut achhe se kiya hh but please slow nd detail mm bnaye bhale hi vedio lambi ho hme knowledge chahiye vedio apko achhi hoti hh kitni bhi lmbi ho koyi frk nhi padta
👉agar chiller water cooled hai to .. maximum basement me lagaya jata hai .......ya phir ground floor pe ...lekin 90 % basement me lagaya jata hai ..... 👉aor agar chiller air cooled typ ka hai to ... maixmum roof top ( tarres) pe lagaya jata hai ....ya phir free of space area me ..👉.yani ki jaha pe air achi flow kare waha pe bhi laga diya jata hai
Moterize valve ek normal valve ki tarah hi kam karta hai bas isko isliye lagaya jata hai ki ham BMS se on ya off kar sake ... Aor balencing valve ko out line me ham is liye use karte hai ki water ko ham condenser me GPM ke hisab se set kar ke rok ke rakhe
Ji ha bilkul sahi .. kaha apne .. qki york chiller ka jo evaporater hai wo fluded typ ka hai ... Jisme tube side me water and shell side me gas hoti hai .... Agar yahi evaporater hamara DX typ ka hota to shall side me water hota aor tube side me gas hoti
sorry for my mistake 🙏 hamne is vidio me evaporetor ki tube me water bataya hai ...lekin evaporater ki tube me hamari refrigrent hoti hai ..sukriya 🙏
Haa sir ji me bhi yahi puchne wala tha
Tanku sir replace
Bhai itna galti mut kiya karo. jo galti hota hai us cien ko cut kar diya karo phir se dubara video bana kar usse sett kardiya karo. Or apka har videos mjhe aacha lagta hai ...👍
Evaporator ke tube me water hi hota hai sir bcoz tubes are in horizontal position and water also flow horizontal so shell contains refrigerant
NRB GALAT BATA RAHE HAI KYO RABER BELO KO NRB BATA RAHE HAI
Bahut behterin knowledge
Very good
good video sir,
Thank you ji 💐
Superb 👌👌👌👌👌sir ji...
thank you
Bahut badhia
Very nice viddo sir
Good
👍
Great sir
❤️❤️🌹🌹❤️❤️
Bahot achha videos bnate ho bro
Sukriya apka
Sir compressor overhauling ka video upload kigeya
thank you sir ,maintenance time ka video s share karo ji
dost bahot si vidio hai maintenance ki ... description me link hai aap dekh sakte hai.. sukriya
Very nice sir bahut achi videos banate hai app
Apka explanation bahut jabardast krte hai bhai 😊
bahoot sukriya ji apka 🤗
Ek video bnaiye bhai jisme pura vapour compression cycle ka kha se kitna temp in out krta h aur refrigerant pressure kha pr kitna hota h
Very helpful vedio
Bahoot sukriya ji apka
ua-cam.com/users/shorts5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
Sir aapki bhut si vedios Maine dekhi h bhut behtrin andaz me samjhate h ap aapki hi ek vedios dekhi thi jisme btay the ki condenser ke shell side me refrigerant aur tube side me water, evaporator/chiller ke shell side me water aur tube side me refrigerant hota h , but aapne yaha dono me same bata rahe h
Ji ha
York chiller me condenser and evaporater me same tarah hota hai ... Qki york chiller ke evaporater fluded typ evaporater hai....
Fluded typ evaporater me 👉tube me water and shell me gas hoti hai
And DX typ evaporater me tube me gas and shell me water hota hai
Reciprocating ya centrifugal compressor me oil kaise change karte hai ustime me kon kon SA tools use karte hai Pura complete ek video banaye oil Ka temperature Kiya Hota hai
Apki awaj mast hai sir
ua-cam.com/users/shorts5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
Prv nd service valve dono me use hota h Evaporator and condensor dono me usw krte h
Make a complete video on chiller power wiring and control wiring each and everything. Thanks
ua-cam.com/users/shorts5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
As-salamu alaikum sir
Bahut bahut shukriya 🙏
Allah aapko apne hibzo aamaan main rakhen🤲
Ji walikum assalam ✨ aor apko bhi
ua-cam.com/users/shorts5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
Nice but How Self identifiyed All parts of chiller
Nice video sir thank you. Sir ek video banaiye oil filter k bare me kaise nikal k uski cleaning hoti hai or fir kaise lagaya jata hai plz
Ok ji jarur
Centrifugal compressor jo use hota h vo high ton ke plant ke liye use hota hena like 400tr se upr jab jata h tab ?????
Nd dosra ye bataiye sir ki
Compressor ka capacity kaise decide hota h ? As per ton yah kuch or
Same waise hi mujhe puchna h pump se related uska hp capacity kaise lete h as per ton yah as per heat load calculation
I know questions bhut sare ho gye but aap short me bata do
Yaah is par koi video bana do sir please
Compressor
Pump
Nd also cooling tower ka sabke capacity kaise niaklate yah pata krte h .agr koi project plan chilled water ka like 1000 tr ka
Agr kise ne pucha ki is plan me Compressor cooling tower pump ka kya capacity h toh kaise me bataun ? Without looking machine i hope aap samjh gye honge question sir
Please sir 🙏
Sir ak video trane k chiler pr bnao
Bhai ek confusion hai..jab direct evaporator line se direct ahu mai cold water and hot water in or out hota hai toh chw pump kyu lgte hai
Sir ek BAAT aur bataye agar ek chiller me tin ya char centrifugal compressor laga hua hai aur usme se ek me koi problem hogaya jisko maintenance Karna Hoga to us situation me Kiya krege chiller ko off Karke maintenance Hoga ya chiller chaltarahega aur uska maintenance Hoga ye questions mujhse client pucha hai
Aap chiller chala sakte hai ۔۔koi problem nahi hai qki har compresser ki alag alag circuit bani hoti hai ۔۔۔bas dhayan rahe ki full shafty ke sath agar running chiller pe work kare to sukriya
Hume injection moulding chiller plant ke bare me sikhna hai not in hvac
Painal ki testing bataiye sir please
Bhai aapne flexible bellow ko nrv bataya ending me. i think video me 8:30 min ke bad
Sir kahi lagwa dijiye sir please chiller men
Sir PSI, PSIG ,PSID KYA HOTA HAI.
AUR CHILLER ME YEH UNITS KAHA PER USE HOTE HAI
Yeh teeno me kya difference hai??
Sir please Trane chiier ke bareme video veje
Ji abhi hamare pass to hai nahi lekin ham try karte hai agar kahi milega to ham apke liye upload kar denge sukriya
Bhai voltas ka air cooled chiler hai satandig pressure 90 psi hai aur runing me 15 se 19 psi ho jata hai kya kare
ua-cam.com/users/shorts5D98nA1HuR0?si=rYJxkVFzdY1xHeT3
Sir York chiller me condenser high pressure contact open alarm kaise thik kre
Cooling tower me water level ok rakho .. qki jab cooling tower me water level kam ho jata hai to air suck karne lagta hai jiski vajah se .. aise alarm aate hai ...
Evaporator ke tube me refrigerant hota h aur shell me water.mai pahle 2-3 video dekha hn usme btaya gya h ..plz confirm kijiyega
bahoot sukriya apka ..but tube me water hota hai condenser and evaporator dono me ..
ji bilkul u are right ....condenser ki tube me water hota hai and ..ewaporater ki tube me refrigrent hota hai ...sorry🙏
@@c4chiller9984 its ok bro..we all are learner and hvac field is ocean ..you are doing great work bro..keep it up
@@faizankhan-bo7sl thanks for supporting ji 🙏
sir g oil sum se jo line arhi wo compresor main bh ja rahi un lines ki detail
check the my new vidio ...aaj add ho gai hai
good ! Could you help me with a question I have about the capacity of the York chiller? its capacity set-point
what set point like temperature or TR ?
@@c4chiller9984 Temperature set point is at 9°C and the capacity set point is at 80%. the Chiller does not obey the set points. If I increase the capacity, after the ramp, it goes to 105% and I fell. I'm here on the other side of the world 😀 Brazil. I'm waiting for help 👍 and thank you for your attention!
Dear friend...Do you use Instagram so if you use Instagram then come in my I'd it's my I'd 👉 kgufran195
I give some suggestions by voice not
Ya kon sa chiller tha air cool ki watar cool or kon sa company tha
Water cooled to York company hai
Sir prv ko safety valve bhi bol skte hai ya nahi
PRV ( pressure relief valve)
ji ha bilkul bol sakte hai 🤗 ye bhi ek shefty hi hai
Sir vedio fir se bnaaye please zara slow or derail mm explain kijye please .... Please .... Please.... Bahut achhe se kiya hh but please slow nd detail mm bnaye bhale hi vedio lambi ho hme knowledge chahiye vedio apko achhi hoti hh kitni bhi lmbi ho koyi frk nhi padta
ji jrur bana denge apke liye 🙏
Kis Bajah se Condenser Temprature badhta hai
Jab uska pressure badhta hai
Sir 400 tr ka screw compressor ka chiller kitna amp lega
Answer plz sir
Sir ji , chiller Kahan rahta hai basement me ya fir kisi floor pe ya top floor pe . Pls reply me
Ek interviewer ne mujhse pucha Maine koi bhi 3,4 floor bata diya tha wo bola nhi
👉agar chiller water cooled hai to ..
maximum basement me lagaya jata hai .......ya phir ground floor pe ...lekin 90 % basement me lagaya jata hai .....
👉aor agar chiller air cooled typ ka hai to ... maixmum roof top ( tarres) pe lagaya jata hai ....ya phir free of space area me ..👉.yani ki jaha pe air achi flow kare waha pe bhi laga diya jata hai
Painal se kaun kaun si opret hoti hai aur dB painal se kaun si opret hoti hai
Chillers
Primery pump
Secondary pump
Cooling tower
Ahu
Fcu
Csu
To sir iska conection btaiye sir please please please please please please please drawing se hi bata dijiye sir please
Sir ham chillar compressor Chek kaise Kare sir
Apko kya check karna hai compressor me aap batay ؟؟
What is work of service valve?
Service valve wo hote hai jaha se ham gas charge karte hai gas recovery karte hai .. aor oil charge ya recover karte hai
@@c4chiller9984 thank you ❤️
Sir kitne Tr ka system laga hai
650 ke 4 system hai
Bhai chiller me oil pump kaha ho ta hai
ji bahoot jagah bahar hota hai ...ya compressor ke ander ...but ye jo york ka chiller hai ...isme oil tank ke ander hi oil pump hota hai ..👍
Sir parameters kitna hota h acutely chiller
1. Oil pressure and temp.
2. Refrigerent suction pressure
3. Refrigerent discharj pressure
4.delta T
5.delta P
6. Approach temp.
Why always use balancing valve n motorise valve in. Outline
Moterize valve ek normal valve ki tarah hi kam karta hai bas isko isliye lagaya jata hai ki ham BMS se on ya off kar sake ...
Aor balencing valve ko out line me ham is liye use karte hai ki water ko ham condenser me GPM ke hisab se set kar ke rok ke rakhe
@@c4chiller9984 in line mai kyu nhi lgte ye dono valve
Bhai tumne pehle bola evaporator mein shell mein paani aur tube mein gas & condenser mein tube mein paani aur shell mein gas
Ji ha bilkul sahi .. kaha apne .. qki york chiller ka jo evaporater hai wo fluded typ ka hai ... Jisme tube side me water and shell side me gas hoti hai .... Agar yahi evaporater hamara DX typ ka hota to shall side me water hota aor tube side me gas hoti
@@c4chiller9984 tq u so much agar apko questions puchna he to kaise contact kare ya kuch aur tarika bataav
Ji ye mera instagram id hai 👉 kgufran195
Okay 👍🥰
Very good