Transas(part 5)- 𝐀𝐋𝐀𝐑𝐌𝐒 𝐈𝐍 𝐓𝐑𝐀𝐍𝐒𝐀𝐒

Поділитися
Вставка
  • Опубліковано 8 січ 2025

КОМЕНТАРІ •

  • @atlantianpawanharyana1005
    @atlantianpawanharyana1005  3 роки тому

    Transas(Part 1)= 𝐄𝐂𝐃𝐈𝐒 𝐁𝐀𝐒𝐈𝐂𝐒
    ua-cam.com/video/zESi-W1xrXg/v-deo.html
    Transas(Part 2)= 𝗥𝗢𝗨𝗧𝗘 𝗣𝗟𝗔𝗡𝗡𝗜𝗡𝗚
    ua-cam.com/video/T18CqW5W57Q/v-deo.html
    Transas (Part 3) =𝗨𝗦𝗘𝗥 𝗠𝗔𝗣 (𝐄𝐗𝐏𝐋𝐀𝐈𝐍𝐄𝐃 𝐈𝐍 𝐃𝐄𝐓𝐀𝐈𝐋)
    ua-cam.com/video/XiHUJsJf8yc/v-deo.html
    Transas (Part 4)= 𝐏𝐋𝐀𝐘𝐁𝐀𝐂𝐊, 𝐄𝐁𝐋&𝗩𝗥𝗠 𝗲𝘅𝗽𝗹𝗮𝗶𝗻𝗲𝗱
    ua-cam.com/video/276htADseag/v-deo.html
    Transas(part 5)- 𝐀𝐋𝐀𝐑𝐌𝐒 𝐈𝐍 𝐓𝐑𝐀𝐍𝐒𝐀𝐒
    ua-cam.com/video/U2DYs8B_I6E/v-deo.html
    Transas(part6)=𝗡𝗔𝗩𝗜 𝗣𝗟𝗔𝗡𝗡𝗘𝗥 𝗕𝗔𝗦𝗜𝗖
    ua-cam.com/video/yQQchkrnh2c/v-deo.html
    TRANSAS-(part7)- 𝐖𝐞𝐞𝐤𝐥𝐲 𝐮𝐩𝐝𝐚𝐭𝐞,𝐄𝐍𝐂 𝐎𝐑𝐃𝐄𝐑 𝐯𝐢𝐚 𝐍𝐀𝐕𝐈 𝐏𝐋𝐀𝐍𝐍𝐄𝐑
    ua-cam.com/video/qDoSSORTrps/v-deo.html
    Transas(Part 8)- How to Export Routes & user map
    ua-cam.com/video/8dly2tulo00/v-deo.html

  • @Syakirsify
    @Syakirsify Рік тому +4

    Do you know how to reduce the alarm volume?

  • @rikimarummmc2170
    @rikimarummmc2170 2 роки тому

    Thank you so much for your information.

  • @troyppppp
    @troyppppp 2 роки тому +2

    is there any answer key to navisailor transas 4000 test?.. Thanks👍

  • @pradipdimri2066
    @pradipdimri2066 Рік тому

    Could u pls advise on my transas ecdis the radar overlay is not activating the option has turned orange but radar targets, EBL VRM are showing on Ecdis display.I tried switching off and on both radars and Ecdis but still the option for activating overlay is orange and not green.
    On Ecdis it is showing alert as
    Ecdis: Sensor failure
    S1: no connect
    S1: video timeout. TIA

  • @yaserasnaashari7533
    @yaserasnaashari7533 Рік тому +1

    Thanks
    I have a question ⁉️
    The SIRE inspector asked about alarm list of same ECDIS on one of our fleet vessel and took a observation
    I couldn't find anything regarding that
    Can you please explain it

    • @atlantianpawanharyana1005
      @atlantianpawanharyana1005  Рік тому

      There are 5 mandatory alarms present in ecdis as per IMO that is normally asked by vetting inspector

    • @atlantianpawanharyana1005
      @atlantianpawanharyana1005  Рік тому

      ua-cam.com/video/Zr63jGLdUss/v-deo.html
      U can watch this video at 16:00 minute I have talked about those 5 alarms

    • @ozgurbars5953
      @ozgurbars5953 Рік тому

      You may use data tool and copy alarms from there may be

  • @dartz4232
    @dartz4232 2 роки тому

    Thanks a lot for your video
    Please i have problem in our ecdis
    Transas navi sailor 4000
    I reinstall the software because navi sailor was not working correctly i add all sensor and now it is working well except the alarm sound not working i go to sys config i did not understand what to do or how to config the alarm please can you help me how to fix this and make sailor 4000 recognize the alarm sound device ?

  • @andrearodrigues7608
    @andrearodrigues7608 2 роки тому

    Hi …. , is there a GPS discrepancy alarm setting available for the user to change ?
    Our company require the setting to be 50 mts . However I’m unable to find where to check or change this setting .
    Please assist if you have any info on this .

  • @josefleyva4383
    @josefleyva4383 2 роки тому

    What to do if not showing radar targets in the ECDIs

  • @guillesterespina7101
    @guillesterespina7101 3 роки тому +1

    GOOD DEMONSTRATION..PLS NXT TIME, MAKE IT SLOWLY EXPLAINING..T.Y

  • @aashish9451
    @aashish9451 Рік тому

    Sir my ecdis display showing DISPLAY NOT REAL TIME
    how to remove this alarm

  • @r3x.28
    @r3x.28 2 роки тому

    Thank you so much for the.. I have a question sir.. How can you set the audio alarm to be audble.. i have tried highlight all the alarms but no alarm sounds came... I do see the alarm indicator from the monitor but no alarm sound...

    • @atlantianpawanharyana1005
      @atlantianpawanharyana1005  2 роки тому

      Brother I was never able to mute the alarm just ask your electrical officer to check may be sound system is not working hence u r not getting alarm

    • @r3x.28
      @r3x.28 2 роки тому

      @@atlantianpawanharyana1005 thank you so much sir...

    • @makscomanch2810
      @makscomanch2810 2 роки тому

      Did you found how to switch off buzzer?)

    • @makscomanch2810
      @makscomanch2810 2 роки тому

      @@atlantianpawanharyana1005 I found... omg...)))

    • @makscomanch2810
      @makscomanch2810 2 роки тому +2

      Need to logout, pres settings, after write password: transas. Choose workbench and sound alarm - unmarked. Done...

  • @muzaffarsayeed458
    @muzaffarsayeed458 3 роки тому

    What is the maximum distance/range in waypoint alarm

  • @vivekthakurification
    @vivekthakurification Місяць тому

    I am getting vdr connection lost what to do

    • @atlantianpawanharyana1005
      @atlantianpawanharyana1005  Місяць тому

      There will be vdr cable connected to ecdis (just like other sensor cables) try to check that it might be loose

  • @BelRiose2000
    @BelRiose2000 3 роки тому

    How to disable WO1 AIS Lost target alarm?

    • @atlantianpawanharyana1005
      @atlantianpawanharyana1005  3 роки тому

      U can see in this video bro I have shown that .. in Ecdis u have to reduce cpa and to tcpa alarm values i

    • @jamessapio1142
      @jamessapio1142 2 роки тому +1

      How about W01: low battery how can i remove this sir

  • @grandsoleil56
    @grandsoleil56 7 місяців тому

    Whats the service password 🤔