Siemens Profibus and TIA Portal

Поділитися
Вставка
  • Опубліковано 23 лип 2024
  • Featuring: Profibus Installation best practices and integration with TIA Portal
    Presenter: Howard Wong

КОМЕНТАРІ • 21

  • @keltonreyneke8948
    @keltonreyneke8948 4 роки тому +1

    Good clip, confirmed many of my field observations.

  • @josephaguil1
    @josephaguil1 6 років тому +3

    Hi Howard
    I'm J Antonio and l work for a Pharmaceutical distribución center in UK and lm very interesting about Plc topics.
    I want to say thanks so much for sharing some of you knowledge on line .Your explanation is short ,clear,understandable which is great for a us to understand.Thanks Ines again.

  • @zakariaeddib8772
    @zakariaeddib8772 2 роки тому

    so grateful for this amazing trainning

  • @sararth011
    @sararth011 6 років тому

    Thank you howard wong fot your great information...😄😄👍

  • @patilvikranta
    @patilvikranta 3 роки тому +1

    Really informative video for new learner like me. Thank you for sharing this knowledge session.

  • @celsosilva4310
    @celsosilva4310 3 роки тому

    Very effective webinar, valuable information, thanks for share it with us.

  • @KSA-vh6tv
    @KSA-vh6tv 5 років тому

    THANK YOU VERY MUCH

  • @rafimarsidek3568
    @rafimarsidek3568 4 роки тому

    really really useful. thanks!

  • @I_vantheory
    @I_vantheory 2 роки тому

    great video!!!

  • @GeorgeMan_1981
    @GeorgeMan_1981 6 років тому +1

    How to add unknown device, for example I need to add the multimeter diris A40 in the devices and network...

  • @oscmotorsports4072
    @oscmotorsports4072 4 роки тому

    HI do you do any troubleshooting support? We have a profibus communication issue on one of our devices that is connected to a variable frequency drive.

  • @SamytheBullFitness
    @SamytheBullFitness 6 років тому

    Hi,
    We're working with one of my customers to install the isoPROFIBUS PCI card onto a newer generation motherboard i5 vs P4, we installed the 6AU1390-0AA00-0AA0 / isoPROFIBUS card into the new computer and moved over the XP installation as well, windows loads but the isoPROFIBUS card has an error coming up in device manager (error 37).
    We tried re-installing the driver to no avail and were hoping for an update to the driver or help with this error.
    Basically we would like to run our Thermwood software on a newer generation pc without upgrading the whole machine...
    You suggestions and replies are greatly appreciated.

  • @7Denial7
    @7Denial7 Рік тому

    I have a question about shield grounding. Isn't grounding on both ends of the cable dangerous due to possible potential differences of the ground in those two points???

  • @kinyanjuima
    @kinyanjuima 5 років тому +2

    hey Howard how about now programming and mapping signals that communicate through the profibus network and more on the software side ...its good informative stuff you got here thanks alot .

  • @Automation28
    @Automation28 2 роки тому

    Great

  • @karankalra416
    @karankalra416 6 років тому +4

    Sir can we take certification from online courses

    • @souravsekharnayak
      @souravsekharnayak 5 років тому +3

      Go to CTTC apply for MCCAPC course(Master certificate Course in Automation and Process Control).

  • @Ashishchabha
    @Ashishchabha 10 місяців тому

    Is there any EtherCAT tester available in market?

  • @ibrahemabuawn6298
    @ibrahemabuawn6298 3 роки тому

    Hi Sir did you have anyting concerning the dp coupler 6ES7 158-0AD01-0XA0

  • @dhurvejidhurveji4971
    @dhurvejidhurveji4971 2 роки тому

    Oh