Thanks for sharing information, there is a porto cabin trailer of size 12 mtr x 4mtr. In this 6wc and 12 shower, 7 lavatory. Wc and shower are separate and each has cubical partition, partition wall not touch with ceiling. In this case should i need to calculate 70cfm per wc and open area by 1cfm/ft. How about shower area exhaust per fixture or cfm/ft? Also this space is air conditioned by mini split unit.
Nice video sir , but can we have video on sizing of expansion tank and chemical dosing unit , for chilled water system , i mean can y explain in one layout chilled water syatem such that where we will connect make water line , where we connect Expansion tank line , chemical doing line , air seperator line in chilled water system , and explain how to we start doing commissioning of this system from where we 1st inject water to the system , and do we do hydrostatic test , on what pressure ,, I will be glad sir if y explian it
Also dear sir , asper nfpa 92 for smoke management system , when is the criteria to install smoke extraction system in the building , I mean is there any specific ht of building or area that building should have this system.
Ser ji ye ventilation ki duct design kitne velocity or kitne friction loss per karege aur grill and exhaust diffuser ko design krne k liye kitni velocity per lete h
Tanveer I always prefer to give fresh air Nd exhaust fans in top end offices yes ACH m taking 12 for exhaust and keeping toilet always under negetive pressure our NBC is very very clear about this
Thanks for sharing information, there is a porto cabin trailer of size 12 mtr x 4mtr. In this 6wc and 12 shower, 7 lavatory. Wc and shower are separate and each has cubical partition, partition wall not touch with ceiling. In this case should i need to calculate 70cfm per wc and open area by 1cfm/ft. How about shower area exhaust per fixture or cfm/ft? Also this space is air conditioned by mini split unit.
Tanvir Bhai K liye Dil Se dua Allah Apko Aur Kamyab kare Bahot helpful hain apke videos
JazakaAllah
Amazing explanation in very easy way…. Thanks a lot
JazakaAllah
Very informative video. Pls continue as a series for cleanroom having different classes.
Thank you
Thanks for sharing information, there is a porto cabin trailer of size 12 mtr x 4mtr. In this 6wc and 12 shower, 7 lavatory. Wc and shower are separate and each has cubical partition, partition wall not touch with ceiling.
In this case should i need to calculate 70cfm per wc and open area by 1cfm/ft. How about shower area exhaust per fixture or cfm/ft?
Also this space is air conditioned by mini split unit.
Review the ASHRAE standard's table for all different locations
Nice video sir , but can we have video on sizing of expansion tank and chemical dosing unit , for chilled water system , i mean can y explain in one layout chilled water syatem such that where we will connect make water line , where we connect Expansion tank line , chemical doing line , air seperator line in chilled water system , and explain how to we start doing commissioning of this system from where we 1st inject water to the system , and do we do hydrostatic test , on what pressure ,,
I will be glad sir if y explian it
Also dear sir , asper nfpa 92 for smoke management system , when is the criteria to install smoke extraction system in the building ,
I mean is there any specific ht of building or area that building should have this system.
Ok noted
I will work on these topics, time by time
@@TanweerAhmed thank y sir , جزاك اللة خير
Amazing topic sir ,,,,,
Thank you
Really appreciate your help ❤️
My pleasure 😊, Jazaka'Allah
Superb sir Ji
Jazaka'Allah
could you pls make video on, how to select the duct gauges /THICKNESS FOR - SAD, RAD, FAD, EAD? ON WHAT BASIS WE NEED TO SELECT,
Insha'Allah
Ser ji ye ventilation ki duct design kitne velocity or kitne friction loss per karege aur grill and exhaust diffuser ko design krne k liye kitni velocity per lete h
Watch my duct designing videos
Thanks for this video, if this toilet is part of commercial or industrial building, how much cfm supply cooling need to provide?
Welcome
Sir .. please need ur answer? Can v give supply air to toilet as per ashrae
Assalamualaikum sir ji
CooldStorage ki details video se hame jankari dijiye please
W.salam, ok noted
Good Job …
Thank you
Thanks for your videos. It’s really helping me brother. I would like to ask “where can i get ASHAREA standards book for these ventilation systems”?
Share email or join my Telegram group "HVAC|MEP Engineering"
❤Mashallah sir thank you
JazakaAllah
@@TanweerAhmed sir ap se request ki plumbing standard pe ik detail vedio banwo
Assalam O Allikum Tanveer Bhai...how can we calculate cfm for janitorial area/changing rooms associated with the washrooms? Thanks
W.Salam, As per ASHREA 62.1 Janitor closets, trash rooms, recycling is Exhaust Rate 1 cfm/ft2 and further review standard
Very helpful ❤
JazakaAllah
How to calculate heat load in washing area (WC, Shower, Lavatory)
Do you want to air conditioning in Toilet?
Yes, it's US Army Project.
Heat load calculation is same process as you calculate in other areas
Sir plumbing mein invert level calculation bylaye please
Invert is lower level of pipe or manhole
MAKE VIDEO ON COLD STORAGE DESIGN - FREEZER, CHILLER
I have no experience about it
Basement sump calculation
Ok noted
Make kitchen room ventilation design
Ok noted
Tanveer I always prefer to give fresh air Nd exhaust fans in top end offices yes ACH m taking 12 for exhaust and keeping toilet always under negetive pressure our NBC is very very clear about this
🆗 👍
Thanks for sharing information, there is a porto cabin trailer of size 12 mtr x 4mtr. In this 6wc and 12 shower, 7 lavatory. Wc and shower are separate and each has cubical partition, partition wall not touch with ceiling.
In this case should i need to calculate 70cfm per wc and open area by 1cfm/ft. How about shower area exhaust per fixture or cfm/ft?
Also this space is air conditioned by mini split unit.
Check the table in ASHRAE standard for further details