    Steps:
    1. To begin press and hold the SET and DOWN ARROW until the controller displays HY. Release.
    2. Press and hold the SET and DOWN ARROW again until the controller displays L2. It will flash and change to H-DOT-Y.
    3. Press the UP BUTTON to CF. Press SET. Press DOWN to C. Press SET.
    4. Press DOWN to HY. Press SET.
    5. Adjust to 4. Press SET.
    6. It will flash and go to LS. Press SET.
    7. Adjust to desired lower set point. Press SET.
    8. It will flash and go to US. Press SET.
    9. Adjust upper set point to 4 degrees above lower set point.
    10. Press SET and wait for the controller to display a temperature again. Then press and hold the SET button until the C flashes. Release.
    11. Change the temperature to your desired lower set point temperature. Press SET.