Tie Beam ko yaha main Plinth Beam Bolna Bhul gaya hu. Iske lie maaf kijiyega. Baki ka Video ko Like aur Share kar ke apna pyar mujhpe jarur dikhaye. Thanks
Most important "HIGHLIGHT" or USP of this entire video..is the explanation behind 'why putting 2nos. 12mm dia in upper & 2 nos.10mm dia still in lower tie beam... EXCELLENT 👍👍👍 Rest 4 nos. 10mm dia can easily manage in upper plinth beam...thanks🙏
Very good presentation 👏 👌 👍 💐. Now tell me while erecting the barbed wire on the top, is the wall likely to get weaken or shorten the life span of the wall?
Sir mn apka bht purana subscriber hoon or mjjy bht kushii ho rii ha k ap wapiss active ho gaye hain apny channal pr.... Sir aik request ha mairii k aap koii aik project lay kr uskii dwg perhna or uska total estimate nikaln pooori video series dalain proffesional project kii...... Tnxx & love from islamabad 🇵🇰
as ur fan, ur videos are too good, sir. 🙏🙏 I've a small doubt that, if we do trepizoidal footing r rectangular r square footing for a boundary wall column, it will go into the beside site, sir..? for this what we can do sir..?
Sir, Thank you for your excellent explanation. You are really a fantastic Tuitor. But sir, You did not mention the width of the base column ( substructure )
As you mentioned thickness of PCC and Rcc to be 75 mm, Also share What should be the dimension of Platform (Horizontal and Vertical Dimension ) of Same
Can we make same type of Boundary wall with 4 inch Brick wall thickness, Remain all we will keep same as you are suggesting?Asking regarding 🧱 Brick Thickness 4 Inch instead of 9 inch
Sirb thank you for plinth beam teaching . Accordingly you taught to use 12mm at top otherwise use all four rods 10mm apart frlom this rwo option , may we apply 12mm on all these four rods of plinth beam .
Siir, thank you for your teaching in utube , about boundary wall that ,being a lay man understand about the same .. May i request forr a small elaboration. 1. You taught column size 10 x10 inch. 2. Plinth beam size also 10 x 10 inch . 3.brick wall size also 10 x 10 inch. In column and plinth beam the stirrup or tie up The stirrup 7inch x 7 inch and concrete margin either side (all) 1 inch , this comes 9 inch x 9 inch , the remaining 1 inch can I assume as plastering of 1/2 inch (half inch) x 1/2 inch. For brick wall it come to 9 inch x 9 inch for this also can i assume as plastering of 1/2 x 1/2 inch . Thank you once again please.
hi we are currently building a house and our builder happens to implement a new technique in building the compound wall for our site, he is extending the ground level beam of the house from the inside to the outside and putting a continuous beam for the compound wall and connecting it with the building beam(its not like a beam on a beam, but just connecting in same level). please give your opinion about this type, thank you
Sir here brick work load will act on plinth beam in downward direction as the beam is simple supported on two columns. I think higher dia rod shall be at bottom. If plinth beam constructed on simple pcc on earth then higher dia shall be at top. I am not a civil engg hence I may be wrong.
Sir column to column distance 20 feet kar saktay hn? Or Kia issi boundary wall ko in future rooms K back wall bana saktay Hain? I mean roof ka weight othaye ge wall?
Dear Mr Sah, what will be the approximate cost for construction of 100 feet long boundry wall of 10 inch thickness and 6 feet hight. All specifications as per your video. Please include labour cost also. Thank you.
Tie Beam ko yaha main Plinth Beam Bolna Bhul gaya hu. Iske lie maaf kijiyega. Baki ka Video ko Like aur Share kar ke apna pyar mujhpe jarur dikhaye. Thanks
Make video on shear wall. Reinforcement details of wall in high rise building spanning 60mts above
Sir compund wall ka column eccentric rakhna padega na?? Nahi to footing dusre ke plot mein ghus jayega na??
Sir ,,niche footing ka nahi batya ,jali ka kaise kitna
@@rohankharbanda5918 well point
Coloum ka jo base me jaali bNega wo ketna mm ka rod rahega
Most important "HIGHLIGHT" or USP of this entire video..is the explanation behind 'why putting 2nos. 12mm dia in upper & 2 nos.10mm dia still in lower tie beam... EXCELLENT 👍👍👍 Rest 4 nos. 10mm dia can easily manage in upper plinth beam...thanks🙏
Great ! basic fundamental explanation for layman who intend to build boundary wall structures for their own homes 🙏
Very good and clear demonstration
Thank You Very Much... You are One of My Best Teachers... Love You so Much... If Possible... I'll Meet You One Day
बहुत अच्छे जी 🙏🙏 जानकारी के लिए बहुत धन्यवाद देता हूं।
Apne bahut good explanation ki ,achi tarah se Samj me aa gaya,🙏
Apke samjhane ka tarika accha hai sir , Apke jayse guru ke margdersahan se hi week student v apne aap ko good student ban sakta hai
Ap bhi sikho apne juniors ko v sikhau
I think u r the best in INDIA nice teaching technic & more helpful for freshers
Excellently described . Thanks .
Very good presentation 👏 👌 👍 💐. Now tell me while erecting the barbed wire on the top, is the wall likely to get weaken or shorten the life span of the wall?
No
My favorite civil Er channel😍😍😍😍
Very nice explaination Thanks .Wish you all the best
Mukesh Dada apnar lecture Khub Valo laga
Thanks for explaining in easy way.👍
Most welcome 😊
Bahut Badhiya jankari diya aapne sir.
Bahut badhiya jankari hai sir. 5" wall me coulm ki distance kitna rkhe
Very nice way of explaination
Very nice.
Concise . Thank you
Very well explained sir
Sir mn apka bht purana subscriber hoon or mjjy bht kushii ho rii ha k ap wapiss active ho gaye hain apny channal pr.... Sir aik request ha mairii k aap koii aik project lay kr uskii dwg perhna or uska total estimate nikaln pooori video series dalain proffesional project kii...... Tnxx & love from islamabad 🇵🇰
Very knformative. Pl let me know plinth beam function design etc for compound wall
Very well explained
Mukesh Bhai.. bahut zabardast
great video keep it up. god bless you.
Good video
Informative
Bahot badiya sir 🔥🔥🔥
GREAT BRO.
Great video sir
V.v. good presentation Sir.
as ur fan, ur videos are too good, sir. 🙏🙏
I've a small doubt that, if we do trepizoidal footing r rectangular r square footing for a boundary wall column, it will go into the beside site, sir..? for this what we can do sir..?
Sir,
Thank you for your excellent explanation.
You are really a fantastic Tuitor. But sir,
You did not mention the width of the base column ( substructure )
thanks a lot sir
Excellent Sir
Nice information and explanation keep it up sir
Tq sir it's very useful
Bahut Acha excellent
Nice one bro❣️
Sir , If we fill murram inside compound wall for a height of 5 feet and total wall height 10 feet above ground video me bataya jaisa ban sakte kya?
In short an Excellent 😘😘😘😘 ummah
Very Interesting
Nice information sir.
very important Lecture! Thanks
Well explained👍
Detailed info.thanks
Sir, water supply schemes k liye bhi koi vedio bna de.. jisme WTP, Intake structure and overhead tank construction ka whole process bata de.. plzzzzzz
Thanks
Ur videos are informative
Good informative video bro keep continue hard work 💪and all the best 👍
Very nice plz boq of this boundary wall
Sir ,mere boundary wall main nise 1.5 foot hi diya hain... Future main koi dikkat aiyegi kiya sir??
Sir compund wall ka column eccentric rakhna padega na?? Nahi to footing dusre ke plot mein ghus jayega na??
Yes
BHAGUT ACHAA BHAI
Thanks sir
Thanks sir....👍👍👍👍
Very Nice Sir...
Excellent...
Super sir
Very Good
Very good 👌🏻👌🏻👌🏻
Informative video
Thank you for your video
very informative video sir
great sir
As you mentioned thickness of PCC and Rcc to be 75 mm, Also share What should be the dimension of Platform (Horizontal and Vertical Dimension ) of Same
Do we need to provide expansion joint if the length of wall is more than 100m? If yes, then at what interval?
वहुत अच्छा
Verry good suggestion sir
Thanks
Very good sir
@@pravinbahipatel7127 I want pricast boundary wall construction.
Excellent
Can we make same type of Boundary wall with 4 inch Brick wall thickness, Remain all we will keep same as you are suggesting?Asking regarding 🧱 Brick Thickness 4 Inch instead of 9 inch
Thank you Sir
And layout par jab column ka vertical rod ka specing Kaise lete h is par ek video sir
Very nice video sir , kiya colum ka distance 12 fit rakh saktye h, kiuki mi ek room 11×12 fit ka banane ke liye soch raha hu , please bateiye
yes
@@LearningCivilTechnology thank sir 🙏💕
Awesome.
Sirb thank you for plinth beam teaching . Accordingly you taught to use 12mm at top otherwise use all four rods 10mm apart frlom this rwo option , may we apply 12mm on all these four rods of plinth beam .
Thank you sir jii
Very nice
Brother Mukesh. Pls prepare construction cost details for compound wall with pillars.
Good
Super video sir
Nice info. 👏👏 . If 3"rcc wall 6'height with 6mm sariya at 1'×1' se banaye aur plenth beam coloum 13feet par de to kitna kharch hoga.
nice bro,,,but u said u would explian about foundation part,,,missed it bro
thanks bro....
U welcome
Siir, thank you for your teaching in utube , about boundary wall that ,being a lay man understand about the same .. May i request forr a small elaboration.
1. You taught column size 10 x10 inch.
2. Plinth beam size also 10 x 10 inch .
3.brick wall size also 10 x 10 inch.
In column and plinth beam the stirrup or tie up
The stirrup 7inch x 7 inch and concrete margin either side (all) 1 inch , this comes 9 inch x 9 inch , the remaining 1 inch can I assume as plastering of 1/2 inch (half inch) x 1/2 inch.
For brick wall it come to 9 inch x 9 inch for this also can i assume as plastering of 1/2 x 1/2 inch .
Thank you once again please.
Thanks.sir.
Thnku sir I agree with u sir g
Sir kindly post detailed building estimation i.e quantity calculation abstract,rate analysis ..And give it's excel link..🙏
Thanks ..
Industrial boundary height and residential height different, height maximum is 1.5 Meter in Residential area
Nice video Sir.
A process long life hoga sir ji
Super
Dear Mukesh ji, one question.. if I wanted to have a room at the boundary wall then what would be the changes or modifications. Pls answer
If you don't mind then will you please show me measurements of starting structure of building
How to laying crank bar at slab according to IS CODE plz sir and also show site images
Plot ke Front me column bin ka distance kitna rakhna hai.
3 meter to aapne andar ka btaya
hi we are currently building a house and our builder happens to implement a new technique in building the compound wall for our site, he is extending the ground level beam of the house from the inside to the outside and putting a continuous beam for the compound wall and connecting it with the building beam(its not like a beam on a beam, but just connecting in same level). please give your opinion about this type, thank you
Sir here brick work load will act on plinth beam in downward direction as the beam is simple supported on two columns. I think higher dia rod shall be at bottom. If plinth beam constructed on simple pcc on earth then higher dia shall be at top. I am not a civil engg hence I may be wrong.
Sir column to column distance 20 feet kar saktay hn? Or Kia issi boundary wall ko in future rooms K back wall bana saktay Hain? I mean roof ka weight othaye ge wall?
tie beam ke niche kya brick work kia jayega ya soil filling.
Foundation steel dia.???? And grade of concrete for foundation, columns, tie beam?????
Ye normal boundary wall hain... isme foundation ke lie steel nahi lagega. Grade of concrete for Foundation column and tie/plinth beam - M20
Dear Mr Sah, what will be the approximate cost for construction of 100 feet long boundry wall of 10 inch thickness and 6 feet hight. All specifications as per your video. Please include labour cost also. Thank you.
Sir what should be the grade of steel used in column and beam?