How to install cuplock scaffolding assembly

Поділитися
Вставка
  • Опубліковано 5 вер 2024
  • How to install cuplock scaffolding assembly.Metecmetal Group is a professional manufacturer of cuplock scaffolding assembly

КОМЕНТАРІ • 35

  • @Monkee88
    @Monkee88 9 років тому +12

    Next time use ten ft material 10ft legs will not stand on its own. One should of been building the other passing the materials

    • @ripstevens2338
      @ripstevens2338 8 років тому

      yuppp how are they just gonna let the legs stand like that? even if its a 5 that aint proper

    • @richardleamy7972
      @richardleamy7972 5 років тому +3

      Standers are 9ft if never seen a 10ft one but I know what you mean how not to erect scaffolding when your boss is watching if I took that long to put that bay well let's say I'd be demoted to labourer lol

  • @kevinclifford2637
    @kevinclifford2637 7 років тому +14

    Title is wrong, should read, How NOT to install cuplock scaffolding assembly

  • @adrianchavez2543
    @adrianchavez2543 4 роки тому +2

    You can tell these guys work in the office and only chose them for the video while the real workers are out in the field SMH

  • @hunanworldscaffoldingco.lt7232
    @hunanworldscaffoldingco.lt7232 4 роки тому

    It's practice?

  • @willmill409
    @willmill409 8 років тому +2

    I was taught u only need to put bars for every 4 cups is this true?

    • @joshua5150headfirst
      @joshua5150headfirst 7 років тому

      jimbob no it's count 1,2, and then three where the bar goes, and if you have a tall scaffold over 10 foot it's 1,2,3,then 4 where the bar goes then handrails then boards or metal pans then hand rails and knee rails, toe boards etc.

    • @ianflores5044
      @ianflores5044 5 років тому

      @@joshua5150headfirst what happend with the jack pads?

    • @offroadchevy4x496
      @offroadchevy4x496 5 років тому

      Every 4 cups is where the strength is.

    • @DifficultE24
      @DifficultE24 5 років тому +1

      You have to have bars every 6’6” which is equivalent to 4 cups. My advice...report this video and never watch it again.

  • @goatmode1247
    @goatmode1247 2 роки тому

    Imagine these two building up 40ft then going around a chimley 😂😂

  • @anthonytomlinson2877
    @anthonytomlinson2877 9 років тому +1

    Poor! Both guys let the standards go. (they could fall at any time) the one closest to the screen forgot to open the cups to place the 1.3 transom in. All cuplock components were not in reachable distance. if that is a professional way to install cuplock god help the people who have done it that way. They made it look so hard.

  • @katyterrell1379
    @katyterrell1379 5 років тому

    Am I missing something or did they not use a torpedo to level it? Also, go 3 cups up and place a hor on the 4th. This is different scaffold than what I do so I guess it's right?????

    • @marthelarzate6229
      @marthelarzate6229 11 місяців тому

      Since it’s concrete they just preset the jacks to the same height assuming concrete is level everything should be level also some places rules double wrap scaffold when beginning

  • @jessegomez5246
    @jessegomez5246 8 років тому +1

    do they make starter cups?

    • @derekmartin1938
      @derekmartin1938 7 років тому

      Jesse Gomez nahhh bro just cut one like we all do

  • @mitchiedjdotcom
    @mitchiedjdotcom 8 років тому +2

    dont know what country this is filmed in but... no handrail, brace, access or fully decked health and safety would have a field day on this and thats after they are done going over the ppe matter.

  • @prasannabehera1857
    @prasannabehera1857 5 років тому

    nice

  • @sergioblanco6321
    @sergioblanco6321 5 років тому +2

    No barricade wtf !!! No anything lol osha where are you

  • @puranrawat9209
    @puranrawat9209 2 роки тому

    Kab log setting ka saman chahie aur company ka number

  • @mikehaynes9449
    @mikehaynes9449 6 років тому +1

    Honestly this video is a disgrace they should have put the jack down and then the 5' bar and the 3' bar (sizes just guessing) next to the jack. Then put the leg on the jack and put both bars in the bottom cup and close it so it supports its self and you can keep building from there. The way how they set that up could have probably fell over on to some expensive equipment or could have hit a valve the made a gas leak depending on where you're working. Try again guys. Not this time.

  • @harshpatel7483
    @harshpatel7483 2 роки тому

    मुझे खरीदना है ।

  • @mirhasanansari123
    @mirhasanansari123 5 років тому

    Unsafe condition erect the scaffold

  • @metecmetalmete7471
    @metecmetalmete7471  9 років тому +1

    How to install cuplock scaffolding assembly

  • @rosariogordo3904
    @rosariogordo3904 6 років тому

    You don't know how to close a cups he has his hand too close to to the strike zone rookie mistake

  • @ericlinsangan1153
    @ericlinsangan1153 2 роки тому

    why not wearing safety shoes?? hahaha

  • @djwhitezz
    @djwhitezz 3 роки тому

    thatd not how you install cuplok thats some clown deals going on

  • @mr.master3085
    @mr.master3085 3 роки тому

    जूता तो पहन ले

  • @trevorkeogh5355
    @trevorkeogh5355 4 роки тому +1

    Fools that is all I can say

  • @LordsWatchman
    @LordsWatchman 11 місяців тому

    Cup lock is the worst scaff system. Anything but ringlock should be made illegal