Thank you Sir for such a wonderful explanation regarding the safety precautions to be followed while handling R410a. I'm from Chennai. OG 1T split AC R410a, 5mtrs copper tubing 1/4 and 3/8. Yesterday 8/6/20, the AC technician (unauthorised) simply came fixed the indoor and outdoor units make it to work and went away without doing vaccum even they've not did the pressure check and not even monitored the load using clamp meter. I'm afraid. What to do now? Please suggest.
Sir i want complete vrv test and charging procedure.Can you make videos on that. Like for N2 pressure test we pinch the suction and liquid line separately and then pressure test differently or we join this pipes and pressure test.Also why we flush the charging line with gas.And refrigerant which is we topup was correct or less or more .Please explain.
Sir kya koi trika hai detect krne ka ki system main pta krne k lie ki konsa refrigerant hai R32 ya R410 agr ac main koi sticker na mile bcz dono ka pressure lgbhg same hi hota hai
Sir R410 refrigerant inverter compressor me use hoti to use pump down kese kare Aur inverter compressor constant speed se to Nahi chalta hai Constant speed se chalane ke liye method hoti hai
Sir 410 gas charge kese krni hai system mein ? Ap ne kaha liquid line mein laga kr charge krna hai pr uska pressure tw zyada hota hai please details sir
R410A AC gas kitne din chalte hai sir ji,Mera Hitachi 3 star Split Ac 8 hours chalte hai sir ji,3 years running now, thank you for your wonderful information about AC
hi.all videos are very helpful and thanx for most info. for technicians.please make a video how much longest length for r410 copper tubing and how much highest outdoor fixing.
नदिलाधनी जी r410a के यूनिट को पुंप डाउन करने के लिए मेनिफॉल्ड गेज की जरूरत होती जिसे हाई साइड बल्ब को बंद करके और लो साइड में लो प्रेसर गेज लगा कर चेक करते है की प्रेसर 0से कम होने पर लो साइड बल्ब को बंद कर देते है और यूनिट को ऑफ कर देते है
Thank u for this video.I have not worked on 410a .During my time it was F 12 and F22. Which were common.my First question is it possible to use A recovery unit to reclaim the gas if there is a problem? Or do you suggest that beong environmental friendly it can be relasws onto the atmosphere. Hope U take the time to advice .God Bless
I have lg 1 ton dual inverter split AC in which it has aluminium condenser. O continuously face had leak problem in it after getting repaired from lg due to corrosion. What if i need to replace it with copper condenser coil what are the changes in bill or any effect in cooling or workin of ac. Is it good to do that. Ac used only free 3 year now. It has condenser warranty but i need to pay them service charges again which has cost of me total around 5k till nOw in 3 year
Thank you sir good information. Sir R-410a if condenser block a/c is continues runing is there any pipe damag or blast chances because that time pressure very high please me.
Sir I request u to please Aap apne es channel par full hvac course provide kar do aap starting se last tak lecture upload kar do please sir I request u. Series bna do full hvac syllabus
#swal thanks sir and sir Mey Assam Tezpur se hu Mera nam Shibu Sarkar, and Mera swal hey 32gas ko top up kor sakte hey Kea sir and jese Ki new 32 gas ka ac hey istal Kea hey pipe lamba hua hey usme top up kor sakte hey Kea sir, please sir tell me this question
Sir mai practical work nahi Kiya hu. Aapke channel ke माध्यम se and or bhi kuch practical janta hu. Gulf interview pass ho gya hu to kya mai gulf me jakar work Kar sakta hu.......
Thanks bro... Thoda confused tha ki waha Jane ke baad kaam nahi aane par sayad return bhej to nahi dega company...... Gulf Jane ke baad hame thoda sa help ki jarurat hai..... Doha Qatar ki Challenger company me Mera selection huaa hai.....
@@vikrantprakashrawat39 Koi bhi compny wapas nhi bhejti h tumhare acording wo tumhe kaam degi jitna kr skte ho. Aur gulf cntry me precticly krne ke baad aap achhe se seekh jaoge Apne senior ke sath.
गिरीश सर,
तुम्ही बनवलेली सर्व व्हिडीओ खूपच माहितीपूर्ण, आणि उपयोगी आहेत त्यासाठी तुम्हाला मनपूर्वक धन्यवाद सर
Girish bhai your explanation is super......
I SALUTE....TO U.....
Thanks
Very Nice , Sir
खूपच छान माहिती दिली आहे
Thank you Sir
Very nice explain sir. Lots of thanks.
Sir aap bahoot ache se samjhate ho
Thank you Sir for such a wonderful explanation regarding the safety precautions to be followed while handling R410a.
I'm from Chennai. OG 1T split AC R410a, 5mtrs copper tubing 1/4 and 3/8. Yesterday 8/6/20, the AC technician (unauthorised) simply came fixed the indoor and outdoor units make it to work and went away without doing vaccum even they've not did the pressure check and not even monitored the load using clamp meter. I'm afraid. What to do now? Please suggest.
Sir i want complete vrv test and charging procedure.Can you make videos on that. Like for N2 pressure test we pinch the suction and liquid line separately and then pressure test differently or we join this pipes and pressure test.Also why we flush the charging line with gas.And refrigerant which is we topup was correct or less or more .Please explain.
Sir kya koi trika hai detect krne ka ki system main pta krne k lie ki konsa refrigerant hai R32 ya R410 agr ac main koi sticker na mile bcz dono ka pressure lgbhg same hi hota hai
Hi sir. 410a air conditioner ki piping jyada hone ki vajah se top up kar sakte hain?
Sir R410 refrigerant inverter compressor me use hoti to use pump down kese kare
Aur inverter compressor constant speed se to Nahi chalta hai
Constant speed se chalane ke liye method hoti hai
Thank you very good explanation
Sir 410 gas charge kese krni hai system mein ? Ap ne kaha liquid line mein laga kr charge krna hai pr uska pressure tw zyada hota hai please details sir
Shaheen zubair liquid line m nhe charge krna.. liquid unit m charge krna,,, cylinder ko ulta kr k 410 charge krny hoty takay unit k andr liquid jay.
@@Jabirwaqas sir Aslam walkem sir ap ke video ma na Daka ha HVAC ka Bara ma sir please you make more video
R410A AC gas kitne din chalte hai sir ji,Mera Hitachi 3 star Split Ac 8 hours chalte hai sir ji,3 years running now, thank you for your wonderful information about AC
Hello sir,
290a gas ki jagah par ham log koun si gas use kar skate hai.
404a or 134a use kar skate hai kya ?
Thank you sir very good information 👍👍
Can we do the R410a Refrigerant charge in off the Air condition ?
Very good video sir aap bahut achhi tarahse bat samjate hai aap ki bolneki speed jyada hai thodi kam kare
Sir liquid me Kyo charge karenge compressor to vapour cycle per Kam Karta hai
Sir oil change kr ke kya Gas charge kr sakte hai jaise R22 seR410a
hi.all videos are very helpful and thanx for most info. for technicians.please make a video how much longest length for r410 copper tubing and how much highest outdoor fixing.
Sir ak 410 a.c gas bhi thik h or a. C bhi clean h pr colling nhe kr pa raha h voltage bhi thik h
Sir R 410a ko kya hum top up kar sakhte hain
Sir all types ducting areas kaise nikalte hain ispe video bnao jaise ki round square etc area aur measurements
नदिलाधनी जी r410a के यूनिट को पुंप डाउन करने के लिए मेनिफॉल्ड गेज की जरूरत होती जिसे हाई साइड बल्ब को बंद करके और लो साइड में लो प्रेसर गेज लगा कर चेक करते है की प्रेसर 0से कम होने पर लो साइड बल्ब को बंद कर देते है और यूनिट को ऑफ कर देते है
Good
Sir vrf Ka addressing Karna bataiye video bana ke kese karte he blue star AC
Hi grish sir
Mujhe Aacha laga aapka video thank-you
Mujhe 410A Ka Recovery karne Ka prosiger bataye
Sir. Agar Ac shift karna hai to kya 410a gas ko back karkey ac uninstall karkey Kahi or install Kar saktey hai?
Yes pump down kar sakte hai
Sar positive pressure per negative pressure Kya Hota Hai
Thank u for this video.I have not worked on 410a .During my time it was F 12 and F22. Which were common.my First question is it possible to use A recovery unit to reclaim the gas if there is a problem? Or do you suggest that beong environmental friendly it can be relasws onto the atmosphere. Hope U take the time to advice .God Bless
Sir kya r 22 ki jagah r410 dal sakte hain kya
Nhi daal skte hai uske liye oil change karna padega
I have lg 1 ton dual inverter split AC in which it has aluminium condenser. O continuously face had leak problem in it after getting repaired from lg due to corrosion. What if i need to replace it with copper condenser coil what are the changes in bill or any effect in cooling or workin of ac. Is it good to do that. Ac used only free 3 year now. It has condenser warranty but i need to pay them service charges again which has cost of me total around 5k till nOw in 3 year
Namaste, R32 is also environment friendly, why blend required ?
Because it is flammable it has some limitations
Sir suction pressure vor discharge pressure Kay hai or kaise measure kare batao plz
Sir R-32 ko top up kar sakte hai kya please reply & make video
Sir jo r410 hy ya r 22 hy iska yi code kaisy atay hy inka formula kia hy in code ka
Retrofit compressor lagake 410 charge karsakthe he kya
Nahi, systems bhi 410a ki chahiye
Txv 410 ka lagayenge tho nahi chalega Kya...
@@kabeermohammad2514 nahi chalaga, pressure change, compressor oil, alaga, condencer, evaparater sizes change, ,
Sir copper pipe ke size ke bare me video bnaiye
Sir if compressor LRA is 68
How much AMP going to take
Pls Tel me ...
Sir vrf ka pump down and gas charging par vdo banayie... Pls
Sir I like video ammonia plant Mai LPR or ammonia pump ke batay plz
Sir g R-410a m liquid ks time py charge kren
Mtlb standing pressure dety waqt ya running pressure increase krty waqt
Standing pressure
@@girishshinde running pressure ky waqt nhi?
Sir refrigeration & airconditioning ka book kaha milega and kitne rs.ka milega..
sir you are professional in aircon field.so kindly make video also carrier chiller 30 gtn how to operate and discus his control with full detail
Sir 410a blast kyu hoti h topup krte time
सर r410 के एयर कंडीशन को पंप down करने के लिए क्या सावधानियां की जाएं,
Sir, PLEASE!
जो हमारे मुख्य रेफ्रिजरेंट हैं उन पर वीडियो बनाइए।
R410A price kitna hai now sirji,
Thank you sir good information. Sir R-410a if condenser block a/c is continues runing is there any pipe damag or blast chances because that time pressure very high please me.
Possible hai
Please remove r410 from system check leak or blocks with nitrogen gas
खूप छान माहिती
Aap bhuth aacha se paradhi hai
Sir please tell me, can we top up r32 refrigerant like r22 refrigerant I will be so appreciated you
Cold room ke wairing ke pe bolo sar
R513a ka suction pressure kya hai
Selendar ke andar 410 liquid me hai ya vapour me kaise pata chalega
Cylinder ulta karke gas charge karo usse liquid system me jayega
R410A ac Hitachi 3 star Split ki price kitna hai now
Sir Kay ham R410a Ka seytem ma R32 a chargeg Kar saqtay ha
No
Sir ji R-22 aur R-32 Gass ki refilling vapour me karna sahi ki Liquid me karna sahi hai please bataye.
Hello sir dakin ka cassate ac hai E0 error code araha hai kya problem ho sakti hai
Sir please make one video R404a gas charging details
Nice video 👏👏👏👏
Greet job sir
thank you sir please please tell us about centrifugal chiller
You understand very well sir
ऐसे ही r३२ के बारे में बताइए
Ok
Useful vidro.. Thanks you bro
Heat pump aur cooling tower ka kya connection hai
DX aur chiller me different kya hota hai iske types bhi bataiye
Dx aur flooded chiller ke type hai
@@girishshinde thanks
Mind blowing video sir ji 👍🏻👍🏻👍🏻🙏🙏🙏🙏
Sir 410 is flameable Or not
Not flamable
Sir I request u to please
Aap apne es channel par full hvac course provide kar do aap starting se last tak lecture upload kar do please sir I request u. Series bna do full hvac syllabus
Thanks sir ji
410 refrejent ka high pressure kitna hota hai
480 psig
Nice video
Thanks you sir
1 foot mein kitne gram gas jaati hai
Rohs compressor pe video Bana ni h
Sir r513a iske bare AK video
Very nice video sir. Good information sir. Thank you.
Que...अगर एयर कंडीशन मे कूलिन्ग कोइल मे चोक हो जाता है तो क्या होगा?
Sir. Please Ans...
Cooling kam hogi, Suction pressure kam hoga, coil pe ice jamegi, superheat normal se jada hogi
@@girishshinde thank you sir
Nice video
R410 me R32 gas charg Kar sakte hai ki nhi plz 🙏 next video me bole ga
Ok
Useful....
Thanks
I appreciate your work keep up
Thanks
Good advice 👍...thank you
My pleasure!
#swal thanks sir and sir Mey Assam Tezpur se hu Mera nam Shibu Sarkar, and Mera swal hey 32gas ko top up kor sakte hey Kea sir and jese Ki new 32 gas ka ac hey istal Kea hey pipe lamba hua hey usme top up kor sakte hey Kea sir, please sir tell me this question
Nahi
Nice
Thanks
R410A ... Top up possible?
Can u explain FAHU working and parts
R32a me Kon konsa refrigerant hota h
R125+r32=410a hota h
Good sir
Sir mai practical work nahi Kiya hu. Aapke channel ke माध्यम se and or bhi kuch practical janta hu.
Gulf interview pass ho gya hu to kya mai gulf me jakar work Kar sakta hu.......
Bilkul ja skte ho gulf bro.
No tention aao gulf me sb ho jayega inshaallah
Thanks bro...
Thoda confused tha ki waha Jane ke baad kaam nahi aane par sayad return bhej to nahi dega company......
Gulf Jane ke baad hame thoda sa help ki jarurat hai.....
Doha Qatar ki Challenger company me Mera selection huaa hai.....
@@vikrantprakashrawat39
Koi bhi compny wapas nhi bhejti h tumhare acording wo tumhe kaam degi jitna kr skte ho.
Aur gulf cntry me precticly krne ke baad aap achhe se seekh jaoge Apne senior ke sath.
Sir very nice
Thanks
Nice #refteck
Thanks
Sir where is your institute located ?
How to gas charge 410a inverter ac please explain
Thank you sir
Sir aap mujhe spp ke bare me bata sakte hai
Yes
410 ko liquid me kaise bharenge selendar ulta karke
Sar R22 compresser, oil r410 compressor oil same hai, nahi please give massages
Same nahin hai
@@qaiskhan7954 Bai 410oil ka name bolo bai
Same nhi h bhai
@@AnilKumar-ud1dv 410a synthetic oil
R410= standing pressure :220-225psi , suction pressure: 110-125psi , discharge pressure: 450-500psi,
Yes
Bhai r22 aur R32 ka pressure kya hota h
Bhai y sahi h ke
Sir wall thickness means ?
Tube ki motai
@@girishshinde sukriya