Standard Auto Changeover Switch Connection with Timer And Contactor

Поділитися
Вставка
  • Опубліковано 17 жов 2024

КОМЕНТАРІ • 169

  • @rainaraina5711
    @rainaraina5711 3 роки тому +10

    Sir apki sabhi videos bahut achhi or usefull hoti hai....bahut kuchh sikhne ko milta hai...thankyou sir ......god bless you❤️❤️

  • @adnewwolde7031
    @adnewwolde7031 2 роки тому +5

    Thankyou explanation about automatic change over swich it is so clear keep it up your ability

  • @pakistanintertainment3545
    @pakistanintertainment3545 2 роки тому

    I love you from Pakistan 🇵🇰👍 Very good information۔۔

  • @mksivashankar8257
    @mksivashankar8257 2 роки тому

    Sir amara telugu wala but your videos full understand sir thank you

  • @NaeemKhan-vq3gg
    @NaeemKhan-vq3gg 3 роки тому +2

    Super sir love & respect from 🇸🇦🇸🇦🇸🇦

  • @patelatul1813
    @patelatul1813 3 роки тому +1

    Bahot badhiya Tari ke se explain kiya hai dhanyvad

  • @arvindmaurya7294
    @arvindmaurya7294 3 роки тому

    ser aap ne bahot achh samghaya thode time me, thanks sir

  • @nageshsahu6365
    @nageshsahu6365 3 роки тому +7

    Thank u for point to point clear explanation and very useful or helpful concern cleared

  • @gopalt7789
    @gopalt7789 2 роки тому +2

    சிறப்பு தம்பி 👍 💐

  • @sarvajeetyadav9460
    @sarvajeetyadav9460 3 роки тому +2

    Keep it up sir very knowledgeable video..

  • @mrinalkantichatterjee8581
    @mrinalkantichatterjee8581 2 роки тому

    Bhot aacha sa samjaya aapna thanku

  • @gunvantgotmare7515
    @gunvantgotmare7515 6 місяців тому

    Bahut achhya sir

  • @jobayerhossain1991
    @jobayerhossain1991 2 роки тому

    Better explanation.. Keep it up.

  • @engdarfatgalalyelectrical1076
    @engdarfatgalalyelectrical1076 3 роки тому +3

    Your work is beautiful

  • @eletriciontecnitionchenel2980
    @eletriciontecnitionchenel2980 2 роки тому +1

    Nix work

  • @trinitysamm9370
    @trinitysamm9370 2 роки тому

    i really like your presentation but i will really love it in english. 👍

    • @ElectricalTechnician
      @ElectricalTechnician  2 роки тому

      Watch my video in English in this channel
      ua-cam.com/channels/dKPm5KM99O75NtArFkMDDA.html

  • @umakanthbojanapalli3240
    @umakanthbojanapalli3240 3 роки тому +1

    Valuable information sir

  • @krishnakantprasad2279
    @krishnakantprasad2279 9 місяців тому

    Very nice

  • @premoli8953
    @premoli8953 2 роки тому

    Mast hai sir❤️🙏❤️👌👌👍👍

  • @mjaved2978
    @mjaved2978 Рік тому

    Best hoga hm genset py b aik timer lga den. Jesy main power off hoti ha engine start ho to kuch second k bad breaker close ho.

  • @mozumdaryoutubechannel3787
    @mozumdaryoutubechannel3787 Рік тому

    Excellent

  • @DeepakYadav-vl7dn
    @DeepakYadav-vl7dn 2 роки тому +3

    better explanation keep it up & keep growing up ❤️

  • @markspowerengineering9589
    @markspowerengineering9589 2 роки тому +5

    nice explain but i think GEN side use one timer for best Alternetor of GEN

  • @GAMINGYT-eg6xj
    @GAMINGYT-eg6xj 2 роки тому

    good explan

  • @electronicshelpcare
    @electronicshelpcare 3 роки тому

    Congratulation

  • @farhanshaikh6103
    @farhanshaikh6103 3 роки тому +4

    Nice

  • @bhupendergindran225
    @bhupendergindran225 9 місяців тому

    Nice sir

  • @technicalvideo43
    @technicalvideo43 3 роки тому +3

    Thanks

  • @SukhpalSingh-iu2xd
    @SukhpalSingh-iu2xd 2 роки тому

    Good sir

  • @manpreetkumar1135
    @manpreetkumar1135 Рік тому

    Thank you sir ji .

  • @karmawalaelectric4988
    @karmawalaelectric4988 3 роки тому

    Vire good video👍👍👍👍👍

  • @ibekwechidithompson4853
    @ibekwechidithompson4853 Рік тому

    Hello I have practiced the connection and it worked out fine thanks, please on your diagram please can you tell us how the timer on the generator be arranged, am confused here.

  • @HafeezKhan-qi7jj
    @HafeezKhan-qi7jj 3 роки тому +1

    good

  • @parwezahmad8961
    @parwezahmad8961 3 роки тому +1

    Great work and thanks sir....

  • @ibrahimksesay9955
    @ibrahimksesay9955 2 роки тому +1

    I love how you are presenting
    Wish you could do the same in English
    Thanks so much

    • @ElectricalTechnician
      @ElectricalTechnician  2 роки тому

      For you i Will Create a new UA-cam Channel and explain all video in English

    • @joachinonyedikachi8393
      @joachinonyedikachi8393 2 роки тому

      I will be happy too sir do well to notify me when you create the English version of it

    • @ElectricalTechnician
      @ElectricalTechnician  Рік тому

      English UA-cam channel www.youtube.com/@TheElectricalGuy

    • @tychicusnthenge6414
      @tychicusnthenge6414 Рік тому

      @@joachinonyedikachi8393 did you get the english version of this

  • @Axfar.z
    @Axfar.z 2 роки тому +2

    Very nice video. if it's better to have subtitles.

  • @sauravwarghade9277
    @sauravwarghade9277 3 роки тому

    Eik number bhai...

  • @ownenergy7783
    @ownenergy7783 3 роки тому

    Good job

  • @sameerkhan8840
    @sameerkhan8840 3 роки тому +1

    Sir ganretor auto start and stop bhi hona chahiye uski video bhi bana do

  • @usmankehinde1483
    @usmankehinde1483 2 роки тому +1

    Good presentation,but the language, remember this video uploaded on UA-cam is World wide and not everybody understand Hindi

  • @inspired9770
    @inspired9770 Рік тому

    Please also make one video on same topic with By-Pass manual switch.

  • @aarushkumar2916
    @aarushkumar2916 2 роки тому

    thanks bro

  • @arslanahmad8892
    @arslanahmad8892 3 роки тому +2

    Sir iss change over k zreya generator kasy auto on or off ho ga kindly tell us ?

  • @vishkarmadieselservice3812
    @vishkarmadieselservice3812 2 роки тому

    Thanks sir two dg singel phase and three phase with main is ki wiring ke bare m v video bana

  • @adnanaslam8716
    @adnanaslam8716 3 роки тому +1

    good job
    can u make a thre phase auto change over

  • @bholaprajapati8456
    @bholaprajapati8456 Рік тому

    Sir. Power terminal conetion bhi clear kar sakte hai

  • @runbou3019
    @runbou3019 2 роки тому +1

    Thanksអគុណ👏

  • @hardintechnical
    @hardintechnical 3 роки тому +1

    में आपकी सराहना करता हूँ, सर्किट बहुत सही है, लेकिन कुछ खामियां हैं इसमे.....
    1. लाइट आने पर घर की लाइट ऑफ नही होनी चाहिए भले ही चेंज ओवर में कितना भी टाइम सेट करो।
    2. इतना सब काम सिर्फ एक रिले ओर दो कॉन्टैक्टर और टाइमर से ही हो जाता।
    फिर भी आपके वीडियो की सराहना करता हूँ
    राम राम जी।

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому +3

      Bhai kaam ho jaega bina Timer ke bhi but agar kisi standard Auto Change over switch ka Drawing dekhoge to timer ka use kiya hi jata hai usmai

    • @hardintechnical
      @hardintechnical 3 роки тому +1

      @@ElectricalTechnician sir आपको भी पता है इंडस्ट्रीज में लाइट का चेंज ओवर करते समय ट्रिप नही होनी चाहिए , अगर सिस्टम मैन्युअल है तो बात अलग है।

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому +1

      Tripping se jyada Safety ki jarurat hoti hai sir ji
      Agar itna critical plant hai to aese contactor ka use kar ke change over switch bana ke nahi install kiya jata uske liye ATS Aata hai wo use karna hota hai
      Hope everything is clear now

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому +1

      And agar nahi rakhna time Delay to timer ko remove kar ke connection kar loa 😊

    • @hardintechnical
      @hardintechnical 3 роки тому +1

      @@ElectricalTechnician आप अपनी जगह सही हैं, अब मैं इस टॉपिक पर वीडियो बनाऊंगा जिसमे यही सामान होगा और डिले टाइम भी होगा मगर डिले टाइम तक सप्लाई ऑफ नही रहेगी ।
      प्रतिक्रिया के लिए धन्यबाद आपका।

  • @fernandespeter9232
    @fernandespeter9232 2 роки тому +4

    Your explanation is good, but you kept the secret of the white wires.
    Why there is no mention of white wires????

  • @AjayKumar-my3py
    @AjayKumar-my3py 3 роки тому

    Sir aap relay ke 12 n com se jo supply timer ke no in kar rhe hai .kya ham relay ke NC se timer ke no ko nahi de sakte hai.

  • @s.m.shawon9931
    @s.m.shawon9931 3 роки тому +1

    mother of expense... you can buy a simple module to do the whole things . keep growing.. it's 2021, life is more easier ...

  • @mdsarfaraj8339
    @mdsarfaraj8339 3 роки тому

    Sir ji without timer bhi ye work karta hai no+nc use karte to...

  • @NINADNERURKAR-dc8zw
    @NINADNERURKAR-dc8zw 5 місяців тому

    what software did u used for making the circuit diagram?

  • @parsa123mh7
    @parsa123mh7 2 роки тому +1

    👏👏

  • @Allrfun
    @Allrfun Рік тому

    Sir hamare pass single phase DG hai aur gvt 3 phase supply hai dono KO contactor se interlocking kaise karen please aap iska video ya digram banakar batayen. You tub per Koi video nahi hai iske regarding. So apse rqst hai sir aap hume sikhayen

  • @RamKumar-hp2ff
    @RamKumar-hp2ff 3 роки тому +1

    Sir Ejector ka cantrol wiring video banaiye

  • @salam2321
    @salam2321 3 роки тому +1

    Water level controller
    No burn .I want to use ex coil power ralay with magnetic Contractor . Thermal overload and seclactor switch.how can bro

  • @noorhabib3855
    @noorhabib3855 3 роки тому +1

    Can this system be used ac/dc or ac different doubel feeder supply

  • @narendrathakor793
    @narendrathakor793 Рік тому

    Apne components ac me work kar te he sel to menual dg start karna padega

  • @prashantyewale1085
    @prashantyewale1085 3 роки тому

    Bhai auto change over ko inverter wiring me use kar sakte hai?

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому

      Inverter mai already rahta hai change over switch

    • @prashantyewale1085
      @prashantyewale1085 3 роки тому

      @@ElectricalTechnician extra lagwane ki jarurat nahi padegi?
      🙏 Thanks for reply

  • @gpishikarpurprojectsbyghul9847
    @gpishikarpurprojectsbyghul9847 3 роки тому +3

    Vist( GPI Shilarpur project )and watch easy Automatic Change over switch with easy diagram

  • @Thesbsingh97
    @Thesbsingh97 3 роки тому

    Sir
    is circuit diagram Mein Mujhe Ek chij ka kami lag raha hai.Jaise man Lete Hain Ki Hamari power Chali Gai aur DG set Humne on kar diya to full load per Aane Se Pahle Hamare jitne devices Hai wo dgset ke load per a Jaenge aur is condition Mein low voltage ki vajah Se Hamare device karab sakte hain.
    mera ek suggestion hai agar Ham Dg wale supply main bhi timer ka istemal Karen Taki DG chalu Karte Hain To DG ka power, circuit me 5 second yah 10 s Rukk kar aaye jisse Hamari device safe Rahe

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому

      Aap circuit mai Voltage Monitoring Relay ka use kar lijiye jisse power supply mai koi bhi problem hoa protection mil jae

    • @Thesbsingh97
      @Thesbsingh97 3 роки тому

      @@ElectricalTechnician
      Sir voltage regulator voltage control hoga lekin mai baat kar rha hu....ki jab load dg per chal rha hai aur achanak se power aa jati to load turant power per chala jayega aur ek small moment ke liye device fluctuation mahsoos karenge.....

  • @shahbazhassan7253
    @shahbazhassan7253 3 роки тому

    Accl use karna iss se cheap and best hoga

  • @arvindmaurya7294
    @arvindmaurya7294 3 роки тому +2

    sir ham main supply me . dusare relay ka nc kyon nahi use kar sakte .for extra safety, please advice

  • @satishvasava5457
    @satishvasava5457 3 роки тому +1

    Timer ka use kyu jaruri hai? Agar circuit me timer na le to kya hoga?

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому +1

      Short circuit hoa sakta hai isi liye thoda sa time delay rakha gayaa hai

  • @mahabubalam3329
    @mahabubalam3329 2 роки тому

    M.Alam

  • @SukhpalSingh-iu2xd
    @SukhpalSingh-iu2xd 2 роки тому

    👍👍👍🙏🙏🙏

  • @МойГосподин-д7е
    @МойГосподин-д7е 3 роки тому

    Ничего непонел но очень интересно

  • @rockstarmedia4607
    @rockstarmedia4607 3 роки тому +1

    Hay bro. Apka video good .but last time load conation karneka time video nahi banare. Video may condactor wiring nahi. Hay.

  • @narendrathakor793
    @narendrathakor793 Рік тому

    Sir dg band hoga to 230 volt kaha se layege

  • @jageshwarsahu2050
    @jageshwarsahu2050 2 роки тому

    Hello sir
    Mujhe ATM counter ki power supply inverter se live line par bataiye

  • @arvindmaurya7294
    @arvindmaurya7294 3 роки тому

    sir three phase ka bhi banao

  • @Electrical.knowledge833
    @Electrical.knowledge833 2 роки тому

    sir wiring me relay q use kia hai ?

  • @syedhassnainali2917
    @syedhassnainali2917 3 роки тому +2

    Thank you Sir, please tell me auto door control circuit

  • @indkaif
    @indkaif 2 роки тому

    Sir mujhe ek chiz samjh nahi aaya
    Timer ka 2 no terminal to common hota hai to aap usko NO Q likhe hai or NO bol rhe h please iski btaiye

  • @patsonsikulundu4549
    @patsonsikulundu4549 Місяць тому

    Do it in Englih next time

  • @irfanulla9429
    @irfanulla9429 3 роки тому +1

    Hai sir I need one connection diagram ,for automatic motor on ond of

  • @mimrankiyani
    @mimrankiyani 3 роки тому +2

    The generator is not told to have its own signal, how the generator will turn on or you will

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому +1

      This is only Change over Circuit
      You should make another Circuit to make your Generator ON

  • @thejknnnb
    @thejknnnb 2 місяці тому

    Amf panel connection control circuit explain bro

  • @vinodbankar8942
    @vinodbankar8942 3 роки тому +1

    Relay2 use nhi kiya to??? Generator supply direct relay1 ke NC se diya to????

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому +2

      Kar sakte hai but
      Circuit mai Generator ka power supply available hone ke baad hi change over kare is liye relay 2 ka use kiye hai

  • @786nkm
    @786nkm 3 роки тому +1

    Same vedio English available. Please...

  • @farhanshaikh6103
    @farhanshaikh6103 3 роки тому +1

    App ne abhi tak telegram pe diagram nhi share kiya mujhe diagram chahiye tha

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому +1

      Oh sorry kis Video ka Pdf Cahiye tha aapko ?

    • @farhanshaikh6103
      @farhanshaikh6103 3 роки тому

      @@ElectricalTechnician isse video ka standard auto change over switch

  • @VipulKumar-sk3eu
    @VipulKumar-sk3eu 2 роки тому

    Vfd power wiring aur control wiring diagram connection with explain

  • @MadhuKumari-o4o
    @MadhuKumari-o4o 5 місяців тому

    Plc ka shat auto dg start banao sar g

  • @_fambyo_2977
    @_fambyo_2977 Рік тому

    Generator ko manual chalu karna padega to Yaha auto changeover kaise hua

  • @basudev2011
    @basudev2011 2 роки тому

    ACCL for all these things

  • @umakanthbojanapalli3240
    @umakanthbojanapalli3240 3 роки тому +1

    Three phase sir how to connect

  • @inamkhan9377
    @inamkhan9377 3 роки тому

    Ye system mai serp 1 really say kar skta hun baqi sari chezy nahi lagy ge

  • @dilippandit4504
    @dilippandit4504 3 роки тому

    Jo do mcb laga h uska kya kaam h

  • @khushpreetsingh2241
    @khushpreetsingh2241 2 роки тому +1

    Use single relay and two power contractors.

  • @lekhrajsaini4905
    @lekhrajsaini4905 3 роки тому

    Euro ecmc 40amp ki wiring btao

  • @kalakondanagendra4986
    @kalakondanagendra4986 2 роки тому +1

    Please explaining Telugu brother

  • @mahendrabagul6617
    @mahendrabagul6617 3 роки тому

    सर जनरेटर कैसे स्टार्ट होगा

  •  2 роки тому

    Video title should be language u are speaking...

  • @osvaldobaiaoandre2098
    @osvaldobaiaoandre2098 2 роки тому +1

    gostaria de ouvir em portugues

  • @jageshwarsahu2050
    @jageshwarsahu2050 2 роки тому

    Please answer my questions

  • @khanjawed2908
    @khanjawed2908 3 роки тому

    Iske circuit diagram upload kar den

  • @YuvrajSingh-em3qy
    @YuvrajSingh-em3qy 3 роки тому

    सर जनरेटर आटोमेटिक कैसे काम करेगा

    • @ElectricalTechnician
      @ElectricalTechnician  3 роки тому

      Ye Circuit bas Auto Change over ke liye hai
      Generator start nai hoaga isse

  • @bhupendergindran225
    @bhupendergindran225 9 місяців тому

    Timer ka kya kam h

    • @Gkodia-cp3bu
      @Gkodia-cp3bu 5 місяців тому

      Timer ka Kam yehi hai ki agar normal power supply ake chala jata hai to timer ko ham kuch time delay karke set karte Hain taki normal supply Ane ka kuch time baad start ho ...tab koi accident na ho isliye use kiye hain

  • @Allrfun
    @Allrfun Рік тому

    Sir plz reply Karen