Replacing a Pool Heater Compressor

Поділитися
Вставка
  • Опубліковано 26 сер 2024
  • Sam Behncke with Kalos Services shows us everything we need to do when replacing a pool heater compressor. He goes over the recovery, installation, brazing, evacuation, and charging of a pool heater with a shorted compressor.
    Sam starts by opening up the pool heater and reconfirming the diagnosis. He isolates the compressor and makes sure it is indeed shorted. For a quick recovery, Sam removes the Schrader cores. He also uses a scale to make sure he knows exactly how much refrigerant he's taking out of the system.
    Before pulling out the compressor, Sam does an acid test to make sure there wasn't a burnout. When taking out the compressor, Sam also takes out the filter drier. He tries to cut the copper as close to the compressor and drier as possible.
    With the new compressor in place, Sam covers it in WetRag (link to Refrigeration Technologies website below) and brazes it in. He also brazes in the filter-drier and does a pressure test afterward. There is an insignificant pressure drop and no obvious leaks with bubbles, so Sam can proceed with the evacuation. As with HVAC systems, large hoses work best for pulling deep vacuums.
    The system passes the decay test, and Sam puts new refrigerant into the system (using a scale to weigh in the charge, of course).
    NOTE: Some final testing procedures, such as testing the charge and the amperage, were not shown. Sam did them off-camera.
    Refrigeration Technologies: www.refrigtech...
    Read all the tech tips, take the quizzes, and find our handy calculators at www.hvacrschoo...

КОМЕНТАРІ • 13

  • @RJMaker
    @RJMaker 5 років тому +1

    I really had some concerns when you said "so we can use it again" after checking for acidics.. :-)

  • @oj4253
    @oj4253 9 місяців тому

    How much would a job like this coat? My pool heater is not working. I replaced the capacitor and my fuse keeps tripping.

  • @RayRay-nb7tn
    @RayRay-nb7tn 5 років тому

    Great video on this change out.

  • @piscinaeconstrucao2084
    @piscinaeconstrucao2084 2 роки тому

    Very good my friend!!!

  • @whitesheatingairappliancer7101
    @whitesheatingairappliancer7101 5 років тому

    Who makes the blue vacuum hoses?
    Can that vacuum pump be used around hydrocarbon refrigerant?
    Nice video thank you.

  • @iliodornarcisse7087
    @iliodornarcisse7087 4 роки тому

    i have an heat pump the compressor is r22 can i just change the compress to 410?

  • @melissasantiago4597
    @melissasantiago4597 4 роки тому

    My power button on my pool heater (Hayward for inground pools) will not depress. It is just stuck, like it's jammed or something (thankfull on the off setting). What kind of repair might that be associated with? Suggestion anyone????

  • @piscinaeconstrucao2084
    @piscinaeconstrucao2084 2 роки тому

    Very good

  • @airmechanical7163
    @airmechanical7163 5 років тому

    Nice work.

  • @mattshanks6674
    @mattshanks6674 2 роки тому

    How much do you charge in labor for that service?

  • @joeshearer1247
    @joeshearer1247 5 років тому

    So it was grounded not shorted

    • @HVACS
      @HVACS  5 років тому

      Grounded is shorted... to ground

    • @joeshearer1247
      @joeshearer1247 5 років тому

      HVAC School so you are saying I was right!😇 see you in Atlanta buddy