Stationeers No AC Venus 8 Water is back on the menu

Поділитися
Вставка
  • Опубліковано 4 січ 2025

КОМЕНТАРІ • 26

  • @nylanx5737
    @nylanx5737 2 роки тому +6

    I think a heat exchanger would be more efficient than the radiators (for equalising the two greenhouses). Especially if you install the same vent setup in the new greenhouse (1 vent per frame).

  • @m109rjohno
    @m109rjohno 2 роки тому +1

    Hit refresh and here I am cheers Mick👍🏽

  • @basbekjenl
    @basbekjenl 2 роки тому +2

    An episode really does just fly past

  • @SirKoyas
    @SirKoyas 2 роки тому +2

    i can't belive u made a mess in the greenhouse it was so tidy before 😂
    at least u didn't build a locker

  • @seankirk2713
    @seankirk2713 2 роки тому +1

    I'm definitely adopting the "ore trough" in my game

  • @owenlebeck2410
    @owenlebeck2410 2 роки тому +2

    I would have put the radiators on the wall that why you would have the roof for ventilation. It would have given you higher CO2 expansion and had a closed heating loop on the walls

    • @owenlebeck2410
      @owenlebeck2410 2 роки тому +1

      Also if you put the x gas in it to presser the pipe it will give you why more room to set up the co2 and the o2 exchange and the rooms will equalize if the radiator are on both sides of the wall

    • @cowsareevil7514
      @cowsareevil7514  2 роки тому

      It is just temporary. I wanted to spread out the coolers as much as possible to cool the place down.

  • @Jamweez
    @Jamweez 2 роки тому

    Hi Mick, at 22.24 you never wrote any code for the combuster? did you write something later? or in another video that i missed?

  • @TheDainerss
    @TheDainerss 2 роки тому +1

    When is WIlson scheduled to land at the base?

    • @cowsareevil7514
      @cowsareevil7514  2 роки тому +1

      About the same time as AIMeE if history is any indicator

  • @ScreamingDoom
    @ScreamingDoom 2 роки тому +1

    Is there a reason you didn't use a heat exchanger to cool the new greenhouse? Hooking the winterspawn greenhouse air ducts connect to the new greenhouse's through a heat exchanger would seem a better route than using radiators.

    • @cowsareevil7514
      @cowsareevil7514  2 роки тому

      I was in a hurry. I will need to isolate the rooms later to prevent it getting too cold. I will use a heat exchanger then.

  • @ConnorArchibald
    @ConnorArchibald 2 роки тому +2

    Thanks for the video! I'm really enjoying this series. Quick question though, I'm sure you addressed this in another video but I can't find it. Why do you not use the games recommendation of the ratio of a fuel mix?

    • @cowsareevil7514
      @cowsareevil7514  2 роки тому +2

      You need to look at what is coming out of the mixer. If both gasses are the same temperature then 66.6/33.3 should give the right mix but if the H2 is 200K and the O2 is at 400K. then you need to set the mixer at 50/50 to get the right mix out the outher end.

  • @DarkGarfield83
    @DarkGarfield83 2 роки тому +1

    Can't find it on the patch notes, what have they changed about the harvey batch writing? Love your videos btw!

    • @cowsareevil7514
      @cowsareevil7514  2 роки тому +1

      The harvies havent changed. They have changed the plant growth to be varied so they dont all reach maturity at the same time. When checking the growth state of the plant you wont be able to just check one plant as the other ones could be different.

    • @DarkGarfield83
      @DarkGarfield83 2 роки тому

      @@cowsareevil7514 you're absolutely right. Thx m8.

    • @Touay.
      @Touay. 2 роки тому

      @@cowsareevil7514 rather than using growth, why not seeding 'seeding' and 'mature'? Are those also being removed? edited to add ... ah, you did use seeding.

  • @lionllew8459
    @lionllew8459 2 роки тому +2

    Those pipes going into the H2 Combuster are not the correct color. You monster! Edit: All is forgiven.

  • @lionllew8459
    @lionllew8459 2 роки тому +1

    Mick, are you using insulated pipes in the greenhouse, on a network where transfer of heat might be a good thing, at greater expense? You monster 🤣

    • @cowsareevil7514
      @cowsareevil7514  2 роки тому

      I might have to change that to make sure the water doesn't get too cold.

    • @lionllew8459
      @lionllew8459 2 роки тому

      @@cowsareevil7514 Good point, I didn't think about that.

  • @TianarTruegard
    @TianarTruegard 2 роки тому +1

    I may not be the first comment, but I think I was the first viewer! :D