Very excellent presentation with practicality and theory. Learned a lot of how this thing works. 4 thumbs up with my socks off. All the best to your technical program.
Thanks for the video =) I came here after our motor kept running despite the water tanks being fully depleted. Seems that our pressure switch is faulty based on your video! We will be getting it replaced soon. Thanks again for sharing!
Excellent explanation and simple in nature to understand. keep it up!!! And always keep your explanation in English so that the majority can understand.👍👍
This knowledge shared is really expositional. I am indeed indebted to share with those who will be interested. Thank you for this philanthropic project.
Galing idol yung sa motorpump nmin ang problema malfunction pk yung same pressure switch kya need na reset for 5x pag ng bild up pressure na yun ggana na cya automatic
Yes possible, but the pressure switch must be reconfigure install at the main supply line of both pumps. Using selector ball valves to select pump to be used to control flow of water. Then your pump control switch selector must be on by which pump to used.
Just an update. After looking at this video. I took out the circuit board and service the relay. I'm glad to say its working now. Before the pump wasn't cutting off so I assume the relay contact were sticking. So far its working great. One question though, when the circuit board is out from it assembled position and power is applied to the board, is it normal for the relay to closed? I saw this happening and wasn't sure. But I installed it and its working the way it should. Thanks Randy.
Thanks, very helpful. My Kin pumpcontrol doesn't always start the pump up when water pressure is down. Seeing your video, it's most probably the magnetic switch which is carbonized after 10 years of use.
Great video. Well explained. Can you elaborate how to reduce the pressure? My unit give 4.5 bar and I need it under 4 bar. You had mentioned to turn the spring inside the yellow cover. Can you explain further please
Thanks for the information bro . Last few days ago my pump doing some trouble pump stop pressure switch need rest it's work again for few days than it's will be happened again please tell me what's the exactly issue
Thanks for sharing, the only part I'm missing is when the system has reached max pressure meaning the sensor has reached peak level & motor is switched off, how does sensor remain in that position without the system loosing pressure? I'm also failing to understand how the lose of pressure on the discharge side moves the sensor down. My thinking is highly on the mechanical end, please shed some light on this.
Thanks for watching. If you're not subscribed, kindly subscribe. Referring to your queries, the diaphragm plunger has permanent magnetic, and it triggers the high and low pressure Reed switches. The plunger diaphragm is being pushed by the spring and counter acting on the water pressure inflows. I hope I satisfy you with your doubts. Thanks, and have a great time.
Yes you can use for shallow well. Not required water tank, since your installing non return valve. Once you open your water faucet and pressure decrease it will pump on and cuts off when your shut the faucet or once it reach shutting off pressure. But if standby pressure not always constant, it will not turn on easily.
@@LEARNWITHRANDY8 sir is it possible to use one pump combination for water tank and booster . Supply is shallow well i want use my 3500 ltr. tank at the same time for pressure boosting using only one 1Hp pump.
I learned lot from your vedio I had installed DJ pressure switch but the problem I am facing. My switch is not working when I turn on the tape. I need to cut the supply to switch it on after closing tap after some time pump switch off automatically but again when I am turning on the tape pump is not working automatically again I have to switch off electric supply. Please guide what could be the reason?❤
When the supply water has no water,its automqtic turn off the motor. How about when the water returns or its already available, is the controller automatic turn on the motor?
Hi sir.....in my house no leakage but my automatic kit turning on and off every 5 minutes...without any leakage and without using water...how to fix this problem
Very excellent presentation with practicality and theory. Learned a lot of how this thing works. 4 thumbs up with my socks off. All the best to your technical program.
Thanks for the video =)
I came here after our motor kept running despite the water tanks being fully depleted. Seems that our pressure switch is faulty based on your video! We will be getting it replaced soon. Thanks again for sharing!
This video was most helpful . My relay was stuck in the CLOSED position. Thank you from 🇹🇹 Trinidad
Kindly subscribe. Thanks!
The water in Trinidad is damaging all those pumps
Thank you so very informative. Now I know how a smart head works I never understood before many many thanks.
Excellent explanation and simple in nature to understand. keep it up!!!
And always keep your explanation in English so that the majority can understand.👍👍
This knowledge shared is really expositional. I am indeed indebted to share with those who will be interested. Thank you for this philanthropic project.
Galing idol yung sa motorpump nmin ang problema malfunction pk yung same pressure switch kya need na reset for 5x pag ng bild up pressure na yun ggana na cya automatic
Thanks a lot for this video! It helps me. Could you please explan how you put it together again, especially due to the strong spring.
simple and easy to understand ... thank you
Much appreciated by subscribing to the channel. Thanks
Super helpful breakdown!
Thanks for this vid, it gave me the info required to repair my pressure switch.
Kindly subscribe. Thanks!
Thanks for the illustration. Really gave an insight. Please, can one unit be used to control two pumps in which one pump is on standby?
Yes possible, but the pressure switch must be reconfigure install at the main supply line of both pumps. Using selector ball valves to select pump to be used to control flow of water. Then your pump control switch selector must be on by which pump to used.
@@LEARNWITHRANDY8 Okay, Thanks.
Hello dear,thank you for your knowledge of the pump attachment fixing 🎉
Thank you for sharing your knowledge, I learn more, full support here. God bless.
Thanks for the illustration, great.
Thanks Dear!
Great video. Thanks for the information and operation. I'm going to work on my pump now.
Most welcome! Such comment inspiring me.to share more engineering knowledge. Stay safe and healthy!
Just an update. After looking at this video. I took out the circuit board and service the relay. I'm glad to say its working now. Before the pump wasn't cutting off so I assume the relay contact were sticking. So far its working great. One question though, when the circuit board is out from it assembled position and power is applied to the board, is it normal for the relay to closed? I saw this happening and wasn't sure. But I installed it and its working the way it should. Thanks Randy.
@@ryanhosein7640 Kindly subscribe thanks!
Thanks, very helpful. My Kin pumpcontrol doesn't always start the pump up when water pressure is down. Seeing your video, it's most probably the magnetic switch which is carbonized after 10 years of use.
Using ohmmeter you can verify if nc or no contact happens when you slide up or down the magnet.
@@LEARNWITHRANDY8 yes, thanks
The sensors are Reed switches and the plunger is the magnet. Great video. You can also fool the smart switch with a speaker magnet
Exactly.
Kindly subscribe. Thanks!
Very informative have to watch more, I need to take a course hungry for more information.
Very interesting, 5 minutes more you would have gone through the process of the cover production... love it, thank you...
Kindly subscribe. Thanks!
Very nice video!
Great video. Well explained. Can you elaborate how to reduce the pressure? My unit give 4.5 bar and I need it under 4 bar.
You had mentioned to turn the spring inside the yellow cover. Can you explain further please
Turn the knob to adjust the tension spring. Clockwise to increase, counterclockwise to decrease pressure. Thanks for subscribing.
Thanks for the information bro .
Last few days ago my pump doing some trouble pump stop pressure switch need rest it's work again for few days than it's will be happened again please tell me what's the exactly issue
Thanks for sharing, the only part I'm missing is when the system has reached max pressure meaning the sensor has reached peak level & motor is switched off, how does sensor remain in that position without the system loosing pressure? I'm also failing to understand how the lose of pressure on the discharge side moves the sensor down. My thinking is highly on the mechanical end, please shed some light on this.
Thanks for watching. If you're not subscribed, kindly subscribe. Referring to your queries, the diaphragm plunger has permanent magnetic, and it triggers the high and low pressure Reed switches. The plunger diaphragm is being pushed by the spring and counter acting on the water pressure inflows. I hope I satisfy you with your doubts. Thanks, and have a great time.
Well Explained Brother, Really Useful Video
Kindly subscribe. Thanks!
Thank you for the explanation
Please I need explanation on how to connect the cables
Nice way of explaining
Thanks 😊 bro explained very well 👍
Does it work as a booster or will it draw from a below ground tank?
It can work both ways.
can this be use shalow well supply with foot valve? and is it better to use pressure tank after this or no need to install it.?
Yes you can use for shallow well. Not required water tank, since your installing non return valve. Once you open your water faucet and pressure decrease it will pump on and cuts off when your shut the faucet or once it reach shutting off pressure. But if standby pressure not always constant, it will not turn on easily.
@@LEARNWITHRANDY8 sir is it possible to use one pump combination for water tank and booster . Supply is shallow well i want use my 3500 ltr. tank at the same time for pressure boosting using only one 1Hp pump.
Very good and the best video thank you very much.
I learned lot from your vedio I had installed DJ pressure switch but the problem I am facing. My switch is not working when I turn on the tape. I need to cut the supply to switch it on after closing tap after some time pump switch off automatically but again when I am turning on the tape pump is not working automatically again I have to switch off electric supply. Please guide what could be the reason?❤
Will there still be water flow during power outage?
well done define
Very informative thanks a lot
Very nicely explained 👍
Very good explain,thank you
can i use this together with bladder tank?
Yes
Clear explanation. thank you
Kindly subscribe. Thanks!
Dose this pump work with 110v or 220v
Sir so helpfull vidio thanks for uploading can you make vidio how fix pcb of this pressure switch
Can I use with non pressure pipes
Superb 👌👌
What voltage is used to turn On the relay?
24 volts DC ?
OR
110 volts AC.
24vdc
HI, my APC, cut in in 0 pressure, what can I do to increase it to at least 20PSI? THANKS
When the supply water has no water,its automqtic turn off the motor. How about when the water returns or its already available, is the controller automatic turn on the motor?
Press the button reset
Yes
Thank you Sir for your explanation 😊
Kindly subscribe. Thanks!
thank you very much
Very good explanation
Very good explained sir
Thank you
Thank you 👌❤️
How to adjust the cut off and cut on pressure?
Open the yellow cover and adjust the spring tension. Tight means more pressure, loosen means reduce pressure.
@@LEARNWITHRANDY8 how through tighten up the screw? Or spring?
Thx you explaning
Ano kya problema sir may effect ba yung paglagay ng oower source ndi nila connect yung ground nya
Wala, earthing is for protection, kung may elcb breaker ay magtrip if may voltage leakage and mag discharge ang current direct sa grounding.
Good job my friend
How can I adjust the pressure
Remove the yellow cover and turn the tension spring clock wise.
Nice video
Thanks alooooooooooooooooot sir
Nice one from you sir 💗
Kindly subscribe. Thanks!
Why my automatic pump control starts then stops
Hi sir.....in my house no leakage but my automatic kit turning on and off every 5 minutes...without any leakage and without using water...how to fix this problem
My btali auto switch starts every 15 seconds how to adjust so that if little water leak it should not start.
Sir if water is depleted dba auto off sya , if mag refill na ang tank auto din mag on?
Correct, empty water tank auto off.
👋👋👋👋
How to remove plastic cover above the relay???
I need help someone explain the ways removing the cover above relay
Thanks
You can remove it by flipping the cover of the relay using a 4mm flat screw driver.
Pump countinue on so not problem found pls solution
Check water pressure if normal, adjust loosen the pressure spring.
@@LEARNWITHRANDY8 my smart head does not cut off the pump. What to do? How to adjust the spring or sensor?
Pressure switch keep staying on how to fix
Reed switch stucked on closed contact or relay contact stucked. You might be required to disassemble the pressure switch and clean the contacts.
OK thanks
Saan pwedeng magpagawa
Try sa electronic shop, normally relay or Reed switch sensor.
This pressure switch not working
Pressure switch not working hindi
Pre magtagalog k nlang , d Naman Tayo banyaga
Almost 90%subscriber ay di nagtatagalog. My goal is to share my 20 years of engineering experiences
Thanks so much
Most welcome. Kindly subscribe if not subscribers yet