Heat load calculation for cold storage

Поділитися
Вставка
  • Опубліковано 2 лис 2024

КОМЕНТАРІ • 34

  • @johnpingol6716
    @johnpingol6716 Рік тому

    Very knowledgeable thank you! Please do some more videos its very helpful!

  • @sbhosale2101
    @sbhosale2101 4 роки тому +1

    Superb Tutorial on Cold Storage Design

  • @realrahul6944
    @realrahul6944 Рік тому

    Explanation was really good👍

  • @rahulbhosale5074
    @rahulbhosale5074 4 роки тому

    Excellent Information about cold storage.👍

  • @pushpendrapandey705
    @pushpendrapandey705 11 місяців тому

    Good explain.. Thanks🙏

  • @azizenterprises5098
    @azizenterprises5098 2 роки тому +2

    Excellent lecture sir, but I just crossed check the values u selected 8 lamps and you said each lamps will take 100w so that equations answer will be around 11kw, your answer came 3.2kw because you just picked 100w power for all 8 lamps. May be it's wrong please do cross check once, because new comers will be confused if they will also do equations with you.
    Thanks again to give us precious knowledge regarding our field.🙂

    • @sbhosale2101
      @sbhosale2101 2 роки тому

      8 lamps * 100watts = 800watts * 4 hrs = 32000watts = 3.2 kw/hrs

  • @roshnabhosale3402
    @roshnabhosale3402 3 роки тому

    Nice video. Completely understand. Thanks sir.

  • @cramemichael2023
    @cramemichael2023 2 роки тому

    Great Work. Nice Video

  • @elijahravikiran976
    @elijahravikiran976 2 роки тому

    Awesome explanation.
    I have only one doubt
    You have consider in product load
    Temp in as 30 degree celcious
    In our outside temp.is 40 degree Celsius.(In practical fruits can bring in AC trucks up to store room).
    GOD bless you.✍🏻🇦🇪🇮🇱

  • @arjunmohod6886
    @arjunmohod6886 27 днів тому

    Sir can you please explain how to select compressor and other refrigeration components

  • @wasanthagodewitharana3563
    @wasanthagodewitharana3563 2 роки тому

    good work

  • @aryatutor69
    @aryatutor69 2 роки тому +1

    Can u explain how to decide type of compressor, condensor etc required

  • @selfajohnspn8454
    @selfajohnspn8454 3 роки тому +1

    you really explained it

  • @brajeshupadhyay2845
    @brajeshupadhyay2845 4 місяці тому

    u r great

  • @francisobey325
    @francisobey325 2 роки тому

    Good of you

  • @cutebaby_trending_shorts
    @cutebaby_trending_shorts 3 роки тому

    Total load calculated is for per hour so we have to calculate the load according to the pull down time right?

  • @mahmoudmahmed8516
    @mahmoudmahmed8516 3 роки тому

    if i need calculate the total capacity of the cold storage what will be change when calculate the total product that can storage in the room ?

  • @meptutorials7503
    @meptutorials7503  4 роки тому +1

    Heat load calculation for Cold storage

  • @gagan4132
    @gagan4132 5 місяців тому

    Is there any paid course in detail

  • @hujjatulislam4322
    @hujjatulislam4322 2 роки тому

    Hi, we have to calculate the heat load for shelter in extremely cold conditions can you help on this?

  • @billsmallwood3933
    @billsmallwood3933 3 місяці тому

    Why did you not use 800 for the two fans in the second example for their combined wattages like you used 400wattages for the two fans in the first example

  • @RahulGawade123
    @RahulGawade123 3 роки тому

    How to calculate air flow capacity of fan and defrost Wattage required

    • @meptutorials7503
      @meptutorials7503  3 роки тому +1

      Air flow capacity in CFM = HP x 6356 (K Factor) x 80% (Motor Efficiancy) / Motor Static Pressure.

    • @deepakmascarenhas2075
      @deepakmascarenhas2075 2 роки тому

      @@meptutorials7503 without knowing the HP , how can you calculate air flow. Also , how many air changes per hour required this room size wit 24TR Evaporator unit

  • @yashchauhan3224
    @yashchauhan3224 2 роки тому

    Time x wattage gives Kwh and Not Kw/hr

  • @nimaldharmasena3674
    @nimaldharmasena3674 3 роки тому +1

    W=J/s. , kW = kJ/s, What is kW/hr?
    Calculation errors!

    • @sbhosale2101
      @sbhosale2101 3 роки тому +1

      Entire load has been calculated in Kw/hr then converted into ton of refrigeration.

  • @yogeshjadhav-ls6hq
    @yogeshjadhav-ls6hq 3 роки тому

    Wrongly calculated .. he added mechnical and electrical kw together

    • @sbhosale2101
      @sbhosale2101 3 роки тому

      1 TR = 3.5 Kw energy expressed by Evaporator Unit, just like 12000 btu/hr = 3.5 kw