Sir Mera Godrej ka 1.5 Ton Inverter Ac Ecco mode par 5 6 Amp par chalta hai .... par Jab Normal Cooling Mode par karta hu to 6 7 8 9 10 Amp le kar Trip ho jata hai Sir
Vai ak window ac me gas charge korte somoy compressor trip hogiya..Usme 60+psi dhala tha.Amp 8.5 se9.5 tak likha hai bodi me.But o ac 8.5 amp leke cholraha tha.Or achumka over heat hoke bond hogiya.Iske reason keya hai.plz reply
👉Voltage problem 👉 Compressor pumping fail 👉Compressor shutback 👉Capacitor weak 👉AC Servic nahi kiya gaya hoga iske wajah se Over heat hota hoga 👉Condenser fan low Speed Itc
Bahut hi behtreen video banaya sir aap ne
Very good job sir
I heartily salute you sir
Sir, I like your way of explaining, daughter-in-law.
Sir Mera Godrej ka 1.5 Ton Inverter Ac Ecco mode par 5 6 Amp par chalta hai .... par Jab Normal Cooling Mode par karta hu to 6 7 8 9 10 Amp le kar Trip ho jata hai Sir
❤ very good information
Very good information sir ❤❤❤❤❤
Very nice
Dear sir
Hum kaise पहचाने की single phase dubble phase ya three phase ka AC koun sa hai
Kaise पहचाने plz 🙏🙏🙏🙏🙏 reply
Jyada Ton ka compressor jyada psi batayega?
Refrigerator ke over load ki matching kaise kare purane overload kis number ka hai new kis number ka laga sakte hai
Thank you sir
Sir ham.. L.. P. G.. Gas. Se felesigh.... Kar seket... H... Ya. Nahe
Nitrogen se kijiye
Sir mera awal hai 5 psi nitrogen ka pressur daalke agr pressur dischrge pe 150 psi dikhai dera to thik mana jata our hwa bhi nhi jati compressor m
Sir authomatic isteplijer ke 4 prisert kit ka canntion kaise kare 909 transfarmer ka ❤
Ok,
Beautiful
Aap bataiye usko banvana sahi hai ya naya AC khariden
Sir raning capister ya starting capister lagaye
Running Capacitor
❤
Rotary compressor ka method kya haii pumping test kaise hoga
Vai ak window ac me gas charge korte somoy compressor trip hogiya..Usme 60+psi dhala tha.Amp 8.5 se9.5 tak likha hai bodi me.But o ac 8.5 amp leke cholraha tha.Or achumka over heat hoke bond hogiya.Iske reason keya hai.plz reply
👉Voltage problem
👉 Compressor pumping fail
👉Compressor shutback
👉Capacitor weak
👉AC Servic nahi kiya gaya hoga iske wajah se Over heat hota hoga
👉Condenser fan low Speed
Itc
Ac book mrp kitne ki
9450561287 par whatsapp msg kar lijiye details mil jayega
Uske bad vah aisi kam se kam 1 se 2 ghante bad fir se chalu karo to chalta hai
Nice
Why AC level 8 se 9 sal Purana hai Samsung ke service centre se engineer aaya tha vah bata raha tha ki compresser kharab hai
अल्युमिनियम कॉइल है और 9 साल हो भी गया है इसलिए कंप्रेसर बदलने से अच्छा है एसी ही बदल दीजिए.
Vah engineer bata raha tha ki iska condenser coil aluminium ka hai to banvana bekar hai kyunki 10 se 15000 lagbhag kharcha aaega
Bhai 8000 mai ho jata hai
Body Earth Galat check kiye ho aap,isse sahi pata nahi chalta hai, series ke drara sahi check hota hai
Bhai isase v pata chal jata hai, hum to aksar hi aise hi check karte hai
Samsung non inverter split AC 30 se 40 minut chalta hai compressor aur band ho jata hai cooling bhi nahin karta hai
Gas low hai
Outdoor fan speed kam ho gaya hoga check outdoor fan capacitor
Sir aap apna contect number dijiye plz sir plz
Ac ke comprashor kese cheq kare konse gass Kam he r32 ya r410 ya r22