How to - Connect an Inverter at your home with Battery Backup
Вставка
- Опубліковано 11 лип 2024
- As I was connecting an inverter at my shop to provide uninterrupted power supply for computers and 3D printers, I wanted to help you learn the method.
So I made this video completely explaining all the procedure to do so. Make sure you watch the entire video to know all the security warnings.
-----------------//-----------------
DIY Power Socket: • DIY - Extension box to...
-----------------//-----------------
FOLLOW ME ON:
/ mrjcrp
/ mediamilan
/ mr_jcrp
-----------------//-----------------
MORE PROJECTS TUTORIALS and POSTS
www.mediamilan.com
-----------------//-----------------
This is by far the only video I wanted all along as I wasn't sure how backup is connected. Thank you
Nice spoken English. and Smart Work too.
Typical Bharat accent😁
This is indeed a great content. Thank you. You deserve a five star rating!
Nice clear instructions, the best Indian how to video I've seen so far, keep it up. I've subscribed to show my support for your work.
Thanks for this vedio. You made my life easy. You saved me more than USD100. Keep sharing.
This is an excellent video. So clear and informative
You're the best tutorial I've ever watched
Sir, Really it was great to learn from professional people. Thanks a lot.
Thank you so much, i just did my inverter connection to my complex circuit box and you made it super easy for me, it all went super fine
Big boss. How far naa. Can I hit you up?
Sir . It's a nice n superb technique u taught us.. it will help us to install inverter at home safely.thank u
Subscribed for your way of conveying, just pleasing.
Nice clear English, and well presented. The video was to the point and explained lot in less time. (No show of unwanted video time)
Glad it was helpful!
Thank you for this explanation. It was very helpful.
Very Informative! Thanks for the vedeo!
Nice explanation, thanks 🙏
Great video! just wondering, if you keep the inverter outside, is there no risk of liquid damage from rains?
very informative video...please upload more videos related to electrical....
+ankit dhiman thanks for the encouragement
Nicely explained and thanks for the tip..!!
Cool. Thanks.
Thanks for your useful video keep up good work 💪
That was a damn good video, Well explained, would have saved me 2000 rupees if i saw it earlier. the electricians make tht much doe for such a simple connection.
Thanks for sharing your knowledge.
+Milind Thosar you welcome
Well explained 👍
Sir ..Nice video.. ..explaining In english is too good...great sir
Thank you. Nice to see someone appreciating speaking in English.
Excellent tips... Thank you.
You are welcome.
Thanks u Sir Nice information
Very useful video, any video on Split AC connectivity also?
Will make sure that I make a video regarding this.
Great video. Thanks.
Thank you for doing this video in english!
Excellent video.
Very helpful video! Tks!
I have a Prolink 1200 inverter. There is a led backlight & a Cooling fan working working when on. Is it ok to work them always ?
Iiooooo o ooo. Obobooo. H. O ooojoib hhhohhhhhhhbhhhhhhhhhhhhhhhohhhhhu you y y hiuugiuuuuhiihij
Thank you very much sir. Please a question from your video. If the neutral from mains supply is what feeds the UPS and thesame neutral wire supplies negative to the battery for charging. Isn't that mixing positive DC from UPS and AC neutral to charge the battery.?. Please shed more light on this
Nice explanation 👌
Sir thanks for speaking in English nice presentation
Great job man
Thanks so much brother
Excellent thank you
Nice explanation
very informative video Thank you
Thank you!
Very useful vedio,thank u
You are welcome.
Thx for the video bro
Good points 👏 👍
Nice work
Nice video it's short but has all the content
GOOD VIDEO BRO BE BLESSED
ur english so good.
good job...tq for information...
Thank you!
Thanks for the video.
want to how to identify either fridge point/geyser is linked to inverter.
+Suri Babu switch if the main and power of the inverter too. If the fridge or geyser switches off then it's connected to inverter.
mediamilan kk
I liked your language more than your explanation very nice video helped me a lot. Please tell me if I can do the same process using an ups to run my computer and an led in my room.(I have separate mcb for each of my rooms). Please help!
If the ups is 600va then the load will be high on the battery
Hi. How did you touch and connect the main power supply at the input of the main breaker on the MCB?
Mediamilan, Thanks for your very good video. I am using Luminous Zelio 1100
+ Luminous 18048 150 AH battery. My house wiring was done separately for inverter purpose. Normal lighting and large appliance wiring are separate. But I noticed one thing, would like to ask your opinion. During power cuts, when home lighting runs thru inverter, large appliances like Refrigerator, oven, AC, washing machine, Mixer and Water heater don't work as they are separate, but there is power in both positive and negative outlet of each socket of appliances. Is this normal. Please share your thoughts.
Heavy appliances cannot work with Inverter. You need a High VA inverter and it will be very costly.
So avoid Fridge, Washing machine and water heaters.
Very good communication
Thank you, Sir
Well explined...
Nice speech.🙏👍
Thanks sir, pls does the inverter do automatic switching of source of supply
Yes. Inverter will automatically switch on
Good learning
MANY THANKS
I have purchased su-kam eco 1000va pure sine wave ups inverter. Which capacity battery should I use? I have shortlisted 220 ah battery.. is it ok?
Excellent
Amazing video
MD SofIyan Ansari
You can touch + and - of a battery at the same time without a shock hazard if the battery voltage is less than about 48V. That's why telecom backup systems use 48V batteries--it's the safest voltage you can touch without harm. Higher voltages will overcome your skin resistance and put current through your body, which could kill you.
I thought 48v can kill? 24v and 12 v is safer
@@Josh-mi1qt Go buy six 9V batteries. Connect them in series, and then touch the two end contacts. Are you still alive?
@@huskypup3489 6x9=56. Yes I am in heaven now.
Nice work bro
Pls keep inverter and battery in trolley ,don't keep n ground battery will drain soon
Hi Just stumbled on your video. You are a funny person lool. I would like to know if it's possible for the battery to over charge.
Good one.
good work bro
Noticed some sparks while connecting a replacement battery but that didn't bother me installing the new battery as the video clearly mentioned sparks are not to be feared. I did cut the main power to the inverter before installation.
Hi, is this good to connect the output of the inverter to the Wall socket?
good job
Thank you sir ji 🙏🙏
SIR UR ALL VIDEO IS VERY HELPFULL BUT PLEASE MAKE A VIDEO ON MY QUESTION
I dont understand your question. Stop typing in ALL CAPS and explain your issue.
I am amazed that you wired the inverter with the battery live.
Doesn't create a problem
Today I had connected an invertor.But some time it is tripping in overload (not always) but at the time of trip load does not exceed more than 200 watt where as my invertor rating is 700VA.can you tell what may the possible cause
Nice one sir, but what if where the output also has neutral point.
thank you
good expletion
+Kashinath Yalgodkar Kashinath thank you
THANKS
We would like to know the down time to switch if the main power down in how many second inverter could operate the electronic again
Or there is no down time or electric trip while inverter contacted
good job boss
Cool. Thanks.
thank u sir
Very nice video, it could be more helpful if circuit diagram was alsonshown
please how can i connect a sollar panel to luminous zelio 900va and will 300 watts panel be ok?
So i see u comenect a cable from the battery to thw Amps,so how many amps r we supposed to use for the battery to charge
Thankes sir it is youser full
Thank you!
Useful
Hi. Well explained. Is there way to connect in such a way that the devices on the inverter will ONLY come on where main power goes off?
You have draw two lines one as a main line and one as a UPS line. Then whatever is connected to UPS alone will be live when main power goes off
@@Kalaakaar-in thanks but the thing is that even when there is main power, the devices on UPS willl remain on right?
@@saileshchudasamasc Yes it will remain on and it will be charging the batteries
Sorry if i am not clear. I want the devices to remain off when there is normal power and only turn on when nornal power goes off
@@saileshchudasamasc if that’s the case then you need some microcontroller and a relay which applies this logic
If the Inverter is not working or get damaged, How the supply can work?
The DBM have connected to the OUT-PUT of Inverter and main directly connected to Inverter not to the DBM,. Plz clear my doubts
The inverter has a reroute which works when the power comes. And when the power goes off it immediately starts from the backup battery.
Very helpful but can it also work with the generator?
Do u need a change controller for the battery?
Output from inverter. Single phase wire use for load..in case main neutral is cut from grid..any option because single wire using
Good sir
Nice video dear
Hi, What is the rating of the Red output wire from the inverter to the main.
Thanks
Ac doesn't have any negative terminal...in single phase system it has a live and a neutral
Nice
Can i connect two batteries of different AH rating? I have a 200Ah and a 150Ah and wanted to use them both
Nope. You should not. They will try to balance out and in the process destroy
By Mistake when I am trying to connect, Negative terminal wire collided with the positive terminal, which resulted in some minor fire sparks. could you explain if i need to change the battery? or it can be rectified
Awesome
Nice sir
+AZAR BABA thank you
nice videos