  • @soumyadipsharma3896
    @soumyadipsharma3896 4 роки тому +7

    in 31:26 the right side of a inv V curve of alternator in lagging .. so it should be as delta or input power increases pf goes from lag to lead via unity. which is also said by sir in previous section and also seen from the phasor.

    • @rejin843
      @rejin843 4 роки тому +1

      Yes.you are right.moving along a constant field current,for increasing power,pf should move from lagging to leading,same trend as said in the phasor.

    • @Anand___
      @Anand___ 4 роки тому

      Please give solution on this concept of question is
      An alternator operating on infinite bus bar at 0.8 leading of if the load on alternator increase by keeping excitation constant then pf,Ia

  • @shubhankarsarkar1081
    @shubhankarsarkar1081 4 роки тому +2

    You are amazing sir...machine god❤️

  • @Rohan-p3p
    @Rohan-p3p 2 роки тому

    Best teacher

  • @jitendrakumardas8619
    @jitendrakumardas8619 4 роки тому +1

    Ty ♥️ sir
    Complitely understoodable

  • @aduityakaushal7580
    @aduityakaushal7580 3 роки тому +1

    Hello ankit bhaia aka sir..
    Actually I wanted to ask you a question in parallel connection of alternator and infinite bus bar..
    Incase of loaded condition,why we say pf varies from lead to lag when excitation is varied and why we say pf varies from lag to lead when steam input is varied... actually in your video we can start from any case of pf i.e you have started from lagging condition,but I can start from leading pf condition..so it's up to us from which pf we start our analysis...but you generalised it in a statement

  • @arvindkumarrawat2366
    @arvindkumarrawat2366 4 роки тому +1

    THANKS sir ji

  • @sudha7189
    @sudha7189 4 роки тому +2

    Good morning 🌞

  • @rejin843
    @rejin843 4 роки тому +3

    As Mr.Soumyadip said,the pf trend should be lagging to leading,for increased value of power.

    • @Iamriton
      @Iamriton 4 роки тому +1

      Load is increasing from left to right. So instead of concentrating on lag and lead just draw a vertical line cutting 3 inverted curves. You will notice that pf first increases then decreases.

  • @oneinall91
    @oneinall91 3 роки тому

    You are supreb sir❤

  • @chandrashekharbati7157
    @chandrashekharbati7157 4 роки тому +1

    Good lecturr

  • @jitendraprasadmuduli93
    @jitendraprasadmuduli93 3 роки тому

    Thank you sir ❤️🔥🙏🏻

  • @shrikantpujari2148
    @shrikantpujari2148 3 роки тому

    Thanks for this sir

  • @ghnabi2966
    @ghnabi2966 4 роки тому +1

    Sir droop characteristics ka video dal dena

  • @akhileshabrp1604
    @akhileshabrp1604 4 роки тому +1

    Good morning

  • @RAJESHGUPTA-yy2mt
    @RAJESHGUPTA-yy2mt Рік тому +1

    Sir ko lgta hai ki hum log Ganesh ji jo itna fast likh lenge jaise vo bolte hai 😅

  • @KRVigyaanam
    @KRVigyaanam 4 роки тому +1

    sir plz provide droop cs

  • @rajeshchamoli3120
    @rajeshchamoli3120 4 роки тому +1

    Nice content

  • @babundarkumarmaurya888
    @babundarkumarmaurya888 4 роки тому +1

    🙏

  • @navneetkumar2318
    @navneetkumar2318 4 роки тому +1

    Sir, 19:00 lag - unity - lead power factor hoga

    • @KUNAL1991ful
      @KUNAL1991ful 4 роки тому +2

      Navneet Kumar lead unity lag..as you can see ia3 leads ea3 by f3 angle