Greetings, I really doesn't know what the problem can be, what I can say from my experience that maybe something is shorten, maybe some component, but this need to check someone who know electronics. Sometime thy can spot problem and solve for some small amount of money. So it is better to find good technician to solve your problem.
Hello! If i understand you, you want to check if the motor works or not. What I usually perform is when I need to try motor on Alena sw2 I connect the motor and capacitor in one terminal so that i have PHASE and NEUTRAL so that is how i can check one side of the motor, for the other side I just use another PHASE cable on the motor because you have 3 wires on the motor, I think that blue is neutral. For Phobos if your version is AC you can also check like I describe before. The version we sell in our company is DC version of PHOBOS so you can test them with one pack battery just with plus and minus terminal. I hope I helped you. Please subscribe to our channel. :)
Dobar dan. Imamo ovakve motore u zgradi i imamo problem sa jakim lupanjem kapije. Da li imate mozda neke savete? Takodje, malo me buni ako se setuje radni hod motora koji se zaustavi u odredjenoj poziciji u videu na 7:20, gornji motor. Zasto se onda prilikom priiska na daljinski predje ta pozicija i motor radi do samog kraja?
Ovaj tip motora nema klasične limit prekidače zbog toga mora imati postavljene stopere i u otvaranje i u zatvaranje. Kada se učitava putanja preko AUTOSETA on pamti pozicije, ali ukoliko nema stopera u krajnjim pozicijama on će izgubiti putanju koju je imao ranije. Motor inače mora da dođe do stopera i da radi još neko vreme dok ne ugasi motore, jednostavno je takav tip motora, pamti putanju i na kraju isključi gde je zapamćena putanja. Može da se desi da motor cimne kada krene ali kod zatvaranja kapije postoji vreme usporavanja, pa motori usporovaju u krajnjim tačkama.
@@amselectronicnis Aha sad je jasnije, znaci ta zapamcena pozicija je pozicija u kojoj on krece da usporava, ako sam dobro razumeo? Hvala Vam puno na informacijama!
@@991ShadowDancer Ta zapamćena pozicija je krajnja pozicija, on usporava nešto pre toga u zavisnosti od toga kolika vrednost se da za usporavanje. Krajnji položaj treba da bude stoper.
Hi , I did the autoset with no limit switch, but after the process when I open with the remote the gate opens to much basically it’s not remembering the limits , do you know why? Thanks
Hi, yes I know the reason. When I was in BFT on training course, they told us that for this model you need to put stoppers on the both position, open and close. Because this model works with load pressure from motor, when they fill closed or open position with obstacle they stop, so it is important to have stoppers because, control board remember position, but from time to time if you don't have stoppers motor will change position where they been before. So that is main reason why stoppers are important.
Kontakti za start su 60-61, ali bi na njih trebalo dovesti suvi signal, ukoliko inerfon daje napon verovatno za elektroprihvatnik, u tom slučaju bi trebalo postaviti rele da promeni kontakt kad dobije napon i aktivira kontakte 60-61. Pozdrav
Pozdrav, da ne bi pravio poseban snimak samo za to, pogledajte naš snimak na sledećem linku. Potpuno je ista procedura za povezivanje svih tipa fotoćelija. ua-cam.com/video/0BKroIrH2OU/v-deo.html
Pozdrav imam daljinski bft mito 2 koji je vec uprogramiran na jedna garazna vrata ali im je crko motor ostao mi daljinski ljudi su donijeli novi motr bft orginal i daljinski ali sam izgubio a ovaj stari sto je uprogramiran nece da se uprogramira, mozeli se uopce vise uprogramirati?
naravno da moze, samo je bitno da ispostujete proceduru prilikom usnimavanja, potrebno je da nadjete Radio meni, u zavisnosti kakva vam je ploca, ako je bez displeja preko tastera S1, ako je sa displejem potrazite radio, zatim add start buton potrebno je da na daljinskom prvo kliknete oba tastera zajedno dok ste u modu za programiranje a zatim levi. i tako bi trebalo usnimiti daljinski upravljač.
@@ivan-sc5um onda sw1 taster, upali se radio led dioda zatim oba tastera zajedno zatreperi led dioda Radio a zatim levi taster. i to bi trebalo da bude to.
dzięki za pomoc, w instrukcji brak opisu kolorów siłownika, ułatwiłeś mi pracę :)
dziękuję za Twoje cudowne słowa :)
bravo hvala
Hvala, hvala
I fixed same machine on my gate, but keeps burning fuse any solutions please?
Greetings, I really doesn't know what the problem can be, what I can say from my experience that maybe something is shorten, maybe some component, but this need to check someone who know electronics. Sometime thy can spot problem and solve for some small amount of money. So it is better to find good technician to solve your problem.
Hello ! I have a system for a gate with an alena sw2 cpem and phobos AC A50 motor, how can I test if the motor is burnt?
Hello! If i understand you, you want to check if the motor works or not. What I usually perform is when I need to try motor on Alena sw2 I connect the motor and capacitor in one terminal so that i have PHASE and NEUTRAL so that is how i can check one side of the motor, for the other side I just use another PHASE cable on the motor because you have 3 wires on the motor, I think that blue is neutral. For Phobos if your version is AC you can also check like I describe before. The version we sell in our company is DC version of PHOBOS so you can test them with one pack battery just with plus and minus terminal. I hope I helped you. Please subscribe to our channel. :)
Dobar dan.
Imamo ovakve motore u zgradi i imamo problem sa jakim lupanjem kapije. Da li imate mozda neke savete?
Takodje, malo me buni ako se setuje radni hod motora koji se zaustavi u odredjenoj poziciji u videu na 7:20, gornji motor. Zasto se onda prilikom priiska na daljinski predje ta pozicija i motor radi do samog kraja?
Ovaj tip motora nema klasične limit prekidače zbog toga mora imati postavljene stopere i u otvaranje i u zatvaranje. Kada se učitava putanja preko AUTOSETA on pamti pozicije, ali ukoliko nema stopera u krajnjim pozicijama on će izgubiti putanju koju je imao ranije. Motor inače mora da dođe do stopera i da radi još neko vreme dok ne ugasi motore, jednostavno je takav tip motora, pamti putanju i na kraju isključi gde je zapamćena putanja. Može da se desi da motor cimne kada krene ali kod zatvaranja kapije postoji vreme usporavanja, pa motori usporovaju u krajnjim tačkama.
@@amselectronicnis Aha sad je jasnije, znaci ta zapamcena pozicija je pozicija u kojoj on krece da usporava, ako sam dobro razumeo?
Hvala Vam puno na informacijama!
@@991ShadowDancer Ta zapamćena pozicija je krajnja pozicija, on usporava nešto pre toga u zavisnosti od toga kolika vrednost se da za usporavanje. Krajnji položaj treba da bude stoper.
@@amselectronicnis Jasno. Hvala jos jednom na informacijama.
Hi , I did the autoset with no limit switch, but after the process when I open with the remote the gate opens to much basically it’s not remembering the limits , do you know why? Thanks
Hi, yes I know the reason. When I was in BFT on training course, they told us that for this model you need to put stoppers on the both position, open and close. Because this model works with load pressure from motor, when they fill closed or open position with obstacle they stop, so it is important to have stoppers because, control board remember position, but from time to time if you don't have stoppers motor will change position where they been before. So that is main reason why stoppers are important.
@@amselectronicnis thanks, for the ansewer I will try to see what will happen, cheers
Dobar dan još jedno pitanje.
Gde se povezuje interfon? Za otvaranje kapije iz kuće.
Kontakti za start su 60-61, ali bi na njih trebalo dovesti suvi signal, ukoliko inerfon daje napon verovatno za elektroprihvatnik, u tom slučaju bi trebalo postaviti rele da promeni kontakt kad dobije napon i aktivira kontakte 60-61. Pozdrav
Dobar dan, da li postoji mogućnost da napravite snimak kako povezati fotocelije na ovom modelu "alena sw2"?
Hvala vam
Pozdrav, da ne bi pravio poseban snimak samo za to, pogledajte naš snimak na sledećem linku. Potpuno je ista procedura za povezivanje svih tipa fotoćelija.
ua-cam.com/video/0BKroIrH2OU/v-deo.html
@@amselectronicnis hvala vam puno.
Pozdrav imam daljinski bft mito 2 koji je vec uprogramiran na jedna garazna vrata ali im je crko motor ostao mi daljinski ljudi su donijeli novi motr bft orginal i daljinski ali sam izgubio a ovaj stari sto je uprogramiran nece da se uprogramira, mozeli se uopce vise uprogramirati?
naravno da moze, samo je bitno da ispostujete proceduru prilikom usnimavanja, potrebno je da nadjete Radio meni, u zavisnosti kakva vam je ploca, ako je bez displeja preko tastera S1, ako je sa displejem potrazite radio, zatim add start buton potrebno je da na daljinskom prvo kliknete oba tastera zajedno dok ste u modu za programiranje a zatim levi. i tako bi trebalo usnimiti daljinski upravljač.
@@amselectronicnis ploca nema displej ali ima sw1 sw2 i ok taster je li na njoj treba drzati ok dugme posto sam vidio da to rade
@@ivan-sc5um onda sw1 taster, upali se radio led dioda zatim oba tastera zajedno zatreperi led dioda Radio a zatim levi taster. i to bi trebalo da bude to.
@@amselectronicnis ok hvala na odgovoru
Koja je ploca u pitanju? Elektronika?
Help!How to set wicket function?
Sorry but I never heard for that kind of function, can you please describe what this function do, maybe I know this function with another name?
No English!! 😢😢
It will be soon, when I have time to translate everything.
Español