Rectangular Footing Design | Numerical | Rectangular design problem | isolated rectangular footing

Поділитися
Вставка
  • Опубліковано 16 жов 2024
  • This video explains the steps involved in designing of rectangular footing, detailed steps how to solve a problem on rectangular footing has been shown, also checks for one way shear and two way shear has been explained
    The link for the square footing : • Design of footing | Is...
    My Phone : amzn.to/311uFDW
    Amazon Basics 50-Inch Lightweight Tripod with Bag : amzn.to/3ayCdkG
    Laptop : amzn.to/3hi2yGp
    Limit State Design of Reinforced Concrete Design by B.C.Punmia : amzn.to/315UEu2
    Reinforced Concrete Design: IS:456-2000 Principles and Practice : amzn.to/315WLxY
    Illustrated Design of Reinforced Concrete Buildings : amzn.to/349rM62
    Design of Reinforced Concrete Structures : amzn.to/3142DYz
    #rectangularfooting #designoffooting #designofrectangularfooting

КОМЕНТАРІ • 149

  • @ojaswinikammili7489
    @ojaswinikammili7489 3 роки тому +2

    best channel in the UA-cam for structural engineers thank you sir

  • @magibooni875
    @magibooni875 4 роки тому +5

    Hi sir this is my first comment in YT ..great explanation I'm a recent subscriber..all video's r very clear ..in footing series kindly do a numerical on combined footing ..thank you

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +1

      So nice of you, thanks for appreciating my work, support my channel with your friends, combined footing soon i will upload

  • @dannycbe949
    @dannycbe949 2 роки тому +2

    Good explanation.
    You could think of providing a reinforced pedestal to reduce the impact of shear.

  • @nibhabhartee19
    @nibhabhartee19 3 роки тому +2

    sir for calculating Po we use column load only but here you used the total load.Why?

  • @earthlover449
    @earthlover449 12 днів тому +1

    Sir from which IS code you take formula for area of reinforcement. Different UA-cam channels are writing different formulas for area of reinforcement. Please explain

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  12 днів тому

      Its a simplified formula derived from IS 456, you can use it you will get same answers

    • @earthlover449
      @earthlover449 12 днів тому

      @@structuralanalysisanddesign ok sir thank you

  • @vasachisenjubean5944
    @vasachisenjubean5944 4 роки тому +3

    *THANKS A LOT SIR, I WAS WAITING EAGERLY FOR THIS VIDEO*

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +3

      This was specially done for you which you had requested, keep supporting and loving like this and share with your friends

    • @vasachisenjubean5944
      @vasachisenjubean5944 4 роки тому +3

      @@structuralanalysisanddesign Thank you and stay safe

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +2

      You too stay safe, next will be coming up with center line method to find out the quantities

    • @halalmeatshophk
      @halalmeatshophk 3 роки тому +3

      @@structuralanalysisanddesign Sir, at 24:50 you did a mistake. 1155 divide by 113 is 10.2 bars, but u answered 12.36 bars. why?
      if 10 bars is right, then it is under reinforced, right ? how come the calculation method is wrong ?

    • @brigadeshivu
      @brigadeshivu 7 місяців тому

      S correct

  • @chinmoy_ce_135
    @chinmoy_ce_135 5 місяців тому

    Sir if moment are given in the question on shorter side and longer side then how to calculate

  • @bhaskarak4409
    @bhaskarak4409 Рік тому +1

    Bro vertical load lo live load tesukunty same procedure y na bro

  • @suraj__710
    @suraj__710 9 місяців тому

    sir in check for 1 way shear we concluded it as not safe , is it because Tv and Tc value are real close .If Tv = 0.35 and Tc=0.328 then it will be safe , isnt it sir , as there is a good difference here

  • @suraj__710
    @suraj__710 9 місяців тому

    sir do we have to show how the BM at XX equation comes or just write the equation only

  • @earthlover449
    @earthlover449 12 днів тому

    Sir in Ast-1 , % of steel value is coming 0.021. but you worte 0.21. where as 0.021 is less than the required min percentage of steel of 0.12%. please correct me if iam wrong.

  • @Mutant707
    @Mutant707 8 місяців тому

    cant u make a dedidated vedio on patterns for all types of structures

  • @deenkibaatein4778
    @deenkibaatein4778 8 місяців тому

    Hi Bro can you please explain the shoe footing which is eccentric footing where column at edge side.

  • @Jaydev-oj2hx
    @Jaydev-oj2hx 10 місяців тому +1

    Sir,
    Is it mandatory to provide same diameter bars along both directions or can we use lesser diameter bars(say, 10mm bars) for Ast2?

  • @ShivKumar-qw8nd
    @ShivKumar-qw8nd 3 роки тому +1

    Nice way of teaching

  • @gowsiraj2076
    @gowsiraj2076 4 роки тому +2

    Good and neat explanation.... Thank you sir

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +1

      So nice of you, keep watching

    • @gowsiraj2076
      @gowsiraj2076 4 роки тому +1

      @@structuralanalysisanddesign Many thanks to you for clear teaching and explanations about formula derivations... Please do more videos sir☺

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +1

      Sure will try to come up with more videos soon

  • @ankitdubey4949
    @ankitdubey4949 3 роки тому +4

    Nice work man
    Well done
    Clearly explained

  • @sudarshannikam5243
    @sudarshannikam5243 3 роки тому +1

    Thanks sir for this explanation, Sir which bar should be at bottom or top (for footing jali) .Should short bars be at bottom side and long bars should be above short bars? Is it mandatory ? Position of long bar and short bar depend on depth d and d1. It always depending on sequence of calculation of Ast1 and Ast2. Is it mandatory that As1 should be calculated by max BM (M1u) and Ast2 should be calculated by low value of BM (M2u). Because sequence of calculation of Ast1 and Ast2 decides the position of upper side or lower side of bars due to depth d and d1 . Can we calculate As1 by M2u and As2 by M1u vice versa. In footing reinforcement schedule there is no provision of showing Max BM and sequence of Ast1 and Ast2 calculation then how to decide laying position of short bar or long bar (above or below for same jali as a long bar and short bar) ? Please explain sir.

  • @Hariprasad-io3rl
    @Hariprasad-io3rl 2 роки тому +1

    Sir I think u have to take ultimate load as 600kn itself
    Then we will get net pressure as 100kn/m2

  • @abdulzahiraliyi8675
    @abdulzahiraliyi8675 4 роки тому +1

    do we have to provide As1 in the shorter direction?
    do we have to always use the BOTTOM Reinforcement %(As1) while calculating for concrete shear in 1way shear check?

  • @priyabrataghosh9309
    @priyabrataghosh9309 Рік тому +1

    Sir,for net upward pressure of soil,in some books, they took the live load instead of adding 10% of it for calculating the value,here you add 10% with live load for calculating... now I'm confused sir... please reply

  • @rithikavidhu5700
    @rithikavidhu5700 9 місяців тому

    hi sir for ast2 did u take d1^2?

  • @murthy2207
    @murthy2207 4 роки тому +1

    sir, Ast-2 u have not followed clear spacing rule mentioned in table-15 of IS;456. for 415 steel clear spacing should not be more than 180mm. correct me if I'm wrong.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +1

      Check out page number 66 of IS 456-2000, clause 34.5.1, it says as per solid slabs we have to follow and table 15 is for beams, clause 26.3.3 in slabs it says 3 times effective depth or 300mm whichever is smaller.
      I hope i cleared you doubt, thanks for watching

    • @murthy2207
      @murthy2207 4 роки тому +1

      @@structuralanalysisanddesign Yes sir, cleared. Thank you. sir plz teach us edge column footing .... No YT channel did that.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +1

      Definitely i will try to work out that problem

    • @murthy2207
      @murthy2207 4 роки тому

      @@structuralanalysisanddesign sir, for Ast-2 , pt value is less than o.12%. in that case what to do? should provide minimum %?

    • @thecivilboyverma1430
      @thecivilboyverma1430 4 роки тому

      ua-cam.com/video/LD03FfyTu1U/v-deo.html

  • @PraveenKumar-vy4py
    @PraveenKumar-vy4py 4 роки тому +2

    Sir also add a video with design of singly and doubly reinforcement beam. Along with what is balanced reinforcement over reinforcement and under reinforcement section with the graf

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +1

      Hello Praveen, Design of Singly reinforced beam already i have uploaded and also what is meant by balanced, under reinforced and over reinforced sections, please see the playlist in my channel "RCC", if you dont find it leave here one message il give the link.
      Design of Doubly reinforced beam i will do soon

  • @rohitsahu5845
    @rohitsahu5845 4 роки тому +1

    Everyone skip this in rectangular footing area of reinforcement should be calculated two times .i see your video just to verify that

  • @civilexplorer7038
    @civilexplorer7038 3 роки тому +1

    Sir, U explained it very well😍. #Best

  • @hs.markandeyahonnalisiddap5534

    Equal projectons beyond the coloumn are allowed for the design

  • @arbaazmirza5084
    @arbaazmirza5084 Рік тому

    Please mention which codes used ???? In all ur videos...

  • @rohitarya7512
    @rohitarya7512 2 роки тому

    Sir, upward pressure mai to =load on column to total area lai tai hai na
    Sir aap total load to total area lai liyai hai,
    Sir, if i am wrong then help me sir

  • @mohamednaseer9167
    @mohamednaseer9167 4 роки тому +2

    For area of steel reinforcement Ast1 I think u made a mistake ... in the root of the formula it is Bd²... so it should be 400² which is equal to 160,000.. can u please clarify if I am wrong

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +1

      Yes my dear student its BdSqaure and 400square, by mistake i have written only 400 but the answer is correct its done by taking 400sqaure

    • @johnnytun471
      @johnnytun471 Рік тому +1

      He calculated with 400 square, he just forgot to put square sign in formular
      you can check his calculation is correct.

  • @engineermohammedsoyebbadgu3714
    @engineermohammedsoyebbadgu3714 4 роки тому +1

    It is design only by Column Load or Reaction...
    How To We Design If there are also Some Bending force is come during Analysis...
    Like
    Pu 600 KN
    Mx 10 KNm
    My 25 KNm
    Thanks for your Explanation
    Superb 😊😊

  • @vijaybhasker2928
    @vijaybhasker2928 3 роки тому

    sir, why dont you consider footing design biaxial moments i.e, "mx "and "my" ?

  • @Abc-wb2kk
    @Abc-wb2kk Рік тому

    Sir i think you forget to put periphery value in last Two way shear Tv value ... formula is Load/periphery you only took load / Area of punching shear.

  • @suraj__710
    @suraj__710 9 місяців тому

    sir whats the name to be written for Vx andVux

  • @civilstruct4053
    @civilstruct4053 4 роки тому

    sir how u are taking b/L ratio as 40/60 ,is it practicle ????

  • @jessicac6015
    @jessicac6015 3 роки тому +2

    Hello, could you explain where the M1u= 0.138FckBd^2 comes from?

    • @jessicac6015
      @jessicac6015 3 роки тому +1

      Its in 15.20

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  3 роки тому +2

      Hello Jessica, it is the modified formula of Mulim which is given on Page 96 of IS 456-2000 (G 1.1 (c) Formula) i have substituted (Xumax/d) value and got 0.138Fckbd^d and remember its valid only for Fe415. for Fe 250 and Fe 500 (Xumax/d) is different so you get different Mu value.
      I hope i cleared your doubt, keep watching and keep sharing

    • @jessicac6015
      @jessicac6015 3 роки тому +1

      @@structuralanalysisanddesign Thank you! Your videos are very informative :)

  • @kinlleygyamtshookh209
    @kinlleygyamtshookh209 2 роки тому

    sir ... if you could solve a problems on raft footing...

  • @kwalicks
    @kwalicks 3 роки тому

    but as per is code depth is governed my shear only, for safe design of footing.... so how is it possible to adopt depth by calculating moment

    • @brigadeshivu
      @brigadeshivu 7 місяців тому

      Then how to calculate Ast without moment we have to assume Ast and then proceed for depth by shear

  • @raheelfaraz3040
    @raheelfaraz3040 4 роки тому

    Sir my quedtions
    1)is this a confirmed question from 5th unit
    2)i can do same method for scoring
    3)sir due to covid it caries 14 marks
    4) please reply
    4

  • @bagguviswanadh8036
    @bagguviswanadh8036 4 роки тому +1

    And from which code book u took ast formula please let me know

  • @madhusudhan8583
    @madhusudhan8583 Рік тому

    Sir,
    τv =Nominal shear stress 0.33 N/mm² is Greater than, τc=Design shear stress 0.328N/mm² . Hence it is safe in One way shear. This is been explained in your previous rectangular footing design video.

  • @bheemaabhinav7941
    @bheemaabhinav7941 2 роки тому

    Pls explain about flat slabs design

  • @arbeenbaba123
    @arbeenbaba123 3 роки тому

    Sir make a vedio on combined trapezoidal footing for 02 columns

  • @mauliktala7427
    @mauliktala7427 4 роки тому +6

    Sir please upload eccentric footing or corner footing design... it's also much importance now a days

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому

      Ya i will be coming up with those videos also, stay tuned for more civil engineering videos, check out my patreon profile

    • @PraveenKumar-vy4py
      @PraveenKumar-vy4py 4 роки тому +1

      @@structuralanalysisanddesign sir where is this patreon profile

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому

      its just like youtube

    • @sonukumar-bp4wb
      @sonukumar-bp4wb 4 роки тому

      Sir please make a video series on g+2 building structure .I am waiting for a building design . Thanks #abhijeet sir

  • @prabhatrijal
    @prabhatrijal 3 роки тому

    Thank you sir.....
    Sir, it would be so great if you could make a video of design of eccentric loading footing too.

  • @ministryofgirls_
    @ministryofgirls_ 2 роки тому

    Take only axial load while u r calculating soil pressure due to column load not total load sir

  • @uttaranplotter5997
    @uttaranplotter5997 3 роки тому +2

    Sir, well presentation. Ast1 > 0.12% but Ast2

  • @mirwaisoriakhel7419
    @mirwaisoriakhel7419 3 роки тому +1

    its wrong 1/2(L-a) its OK 1/2(L-1/2a) please chick this in Geometry.
    and your explanation very good.
    thanks.

  • @amansah9354
    @amansah9354 3 роки тому

    sir can u pls upload the eccentric footing design ...

  • @khajaazammohiuddin5105
    @khajaazammohiuddin5105 2 місяці тому

    Now a days using fe 500 and 550
    How we design what is formulas

  • @sangavaimkulanthaivelu8217
    @sangavaimkulanthaivelu8217 3 роки тому

    If ast1

  • @vijaybhasker2928
    @vijaybhasker2928 3 роки тому +1

    sir please make a video oncombined footing

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  3 роки тому

      Yes vijay working on it, will be coming up with detailed video

    • @vijaybhasker2928
      @vijaybhasker2928 3 роки тому

      @@structuralanalysisanddesign
      thank you so much for your concern sir. i respect you alot. because you made me to understand subject easily. and seriously no faculty had gave clear lecture than you

    • @vijaybhasker2928
      @vijaybhasker2928 3 роки тому

      @@structuralanalysisanddesign
      but sir, i have little bit of confusion while taking sections in rectangular footing design. please give me clearance about it

    • @vijaybhasker2928
      @vijaybhasker2928 3 роки тому

      @@structuralanalysisanddesign
      thank you sir, please take care

  • @UjjwalKumar-
    @UjjwalKumar- 3 роки тому

    Sir , I have Doubt in 7:45 W is equal to Load Given sir , But Why you took 660 , we should take 600 na Sir .
    Pls Tell me as soon as possible

  • @vijaybhasker2928
    @vijaybhasker2928 2 роки тому

    sir kindly upload design of combined footing

  • @vkchowdary7924
    @vkchowdary7924 4 роки тому

    In Area Calculations why take B/L = 40/60
    This ratio will be taken from column dimensions ?

  • @bajisaidavalishaik5670
    @bajisaidavalishaik5670 2 роки тому

    What if they given bi axial load in question?

  • @Civilzone975
    @Civilzone975 2 роки тому

    Sir I have problem in SFD and BMD of frame structure ☹️☹️☹️☹️

  • @katilnikki7104
    @katilnikki7104 4 роки тому

    Cant we calculate moment with cantilever formula?

  • @bholasontakke
    @bholasontakke 3 роки тому

    Please take problem on combined footing

  • @vjyvncnt
    @vjyvncnt 4 роки тому

    Foundation size if we make same size we get less rft moment will reduce
    Make 4 side same size for construction

  • @imazuddinzoha4260
    @imazuddinzoha4260 4 роки тому +1

    fck means=?
    Is it ultimate compressive strees???
    sir plz reply

  • @rajivprajapati7458
    @rajivprajapati7458 4 роки тому

    Why you don't check minimum reinforcement in case of ast2.

  • @panchalchintan9689
    @panchalchintan9689 3 роки тому

    Can anyone tell me about B/L ratio where this came from🤔

  • @gixerriders1993
    @gixerriders1993 4 роки тому +1

    Are you same from Build it home channel ? Am I right ?

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому +1

      No Madhvendra, This is my first channel

    • @gixerriders1993
      @gixerriders1993 4 роки тому +1

      @@structuralanalysisanddesign don't mind pls thank you your all solutions are so unique & useful for exams ......

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому

      I am very happy that my videos are useful for you, this motivates me to come up with more videos, keep supporting and sharing these lectures to your civil engineering friends

  • @vikasreddy2562
    @vikasreddy2562 3 роки тому

    Sir, why u considered b/l = 40/60

    • @K1M01
      @K1M01 2 роки тому

      Column

    • @K1M01
      @K1M01 2 роки тому

      400/600

  • @rohitsahu5845
    @rohitsahu5845 4 роки тому

    Best bro

  • @garrixergaming692
    @garrixergaming692 4 місяці тому

    Example from RCC BC Punmia 🤩🤩

  • @mariyamir2000
    @mariyamir2000 3 роки тому

    At 40:06 how do we calculate the value of Fu? Plz explain

    • @earthlover449
      @earthlover449 20 днів тому

      You can see the calculation of Fu at 39:30

  • @bagguviswanadh8036
    @bagguviswanadh8036 4 роки тому +1

    I need circler footing problem

  • @kartikshettar2050
    @kartikshettar2050 3 роки тому

    Sir staircase problems upload

  • @bhanusairamoju1128
    @bhanusairamoju1128 2 роки тому

    It should be (T suffix v) < (T suffix c)
    In one way shear

  • @amitsaha2537
    @amitsaha2537 4 роки тому +1

    for net upward pressure , isnt it we should use factored load?? like 1.5*600

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому

      Hello amit, i have not incorporated factored load while calculating upward pressure but if you watch carefully complete video i have factored moment by mutiplying 1.5, its usual practice to use safety factor for moment instead of load

  • @monishabalu622
    @monishabalu622 3 роки тому

    Sir, how to calculate the bending moment in square footing for rectangular column ?

    • @praveenmotovlogger98
      @praveenmotovlogger98 3 роки тому +1

      Consider critical section length i.e (L-a/2) and BM for cantilever is WL^2/2...
      Finaly u wil get Wu(L-a)^2/8

    • @everthinghere3750
      @everthinghere3750 2 роки тому

      @@praveenmotovlogger98 hi Darla

    • @vjyvncnt
      @vjyvncnt Рік тому

      B.m =po.B*L/8(B-b)^2
      But my doubt is how two way shear check for a rectanglurar column squre footing

  • @bagguviswanadh8036
    @bagguviswanadh8036 4 роки тому

    Sir ast1 u in place of dsqure u give n d means instead of 400*400 u given 400

  • @aayushrjl
    @aayushrjl 4 роки тому +1

    Sir next time please use X-X section in X axis and Y-Y section in Y axis , its really confusing

  • @amritkumarbehera7748
    @amritkumarbehera7748 10 місяців тому

    How d= 0.4???

  • @UjjwalKumar-
    @UjjwalKumar- 3 роки тому

    Pu = P/A ( 600/6) = 100Kn/m²

  • @arifshaik711
    @arifshaik711 4 роки тому +1

    why you are not using this formula for Ast calculation Mu=0.87 x fy x Ast d {1-(Ast*fy/(bd*fck))}

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому

      I dont use that formula because it becomes tedious to follow that formula, the modified version of Ast formula which i use is very easy to use and apply, please refer Limit State Design of Reinforced Concrete by B.C.Punmia for that theory how the formula is modified, i recommend to use modified version for simplicity, however both formula gives same Ast.

    • @arifshaik711
      @arifshaik711 4 роки тому

      Tq so much sir for giving clarity, I did one footing design with reference of your video that is sq footing and rectangle column I'll send it Plz check sir.....

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  4 роки тому

      sure

  • @georgen9755
    @georgen9755 Рік тому +1

    hand writing not in compliance

  • @tarun8741
    @tarun8741 2 роки тому

    Ast 2 is wrong answer sir

  • @kids-nv7et
    @kids-nv7et 6 місяців тому

    design safe eddida mad ri sir 😢😢

  • @dheerajkhanal7251
    @dheerajkhanal7251 4 роки тому

    circular footing bolo sir. voh kohi thik sey nahi bolrey. plze explain that.

  • @tejavajrala7190
    @tejavajrala7190 3 роки тому +1

    Wrong solution..B value is taken wrong. At Vx it is raken as 2000 and at Tv it is taken as 3000..ive wasted my time looking at this video. Observe from 29th minute. DISAPPOINTED.

    • @structuralanalysisanddesign
      @structuralanalysisanddesign  3 роки тому +3

      Solution is not wrong, at 33:22 i have corrected as 2000, while writing i made mistake but value calculated is correct