Re, Convection Coefficient and Nusselt No. Calculations in ANSYS Fluent

Поділитися
Вставка
  • Опубліковано 24 жов 2024

КОМЕНТАРІ • 45

  • @nuramuaz499
    @nuramuaz499 5 років тому +10

    Its really commendable and it simplified the method of numerical analysis, especially calculation of Nu and h in Post-processing module. However, I observed the turbulence intensity you calculated is 0.0464 and it should be inputted as %, so it suppose to 4.64, not 0.0464. once more congratulations and thank you for enlightening us.

  • @realkanavdhawan
    @realkanavdhawan 5 років тому +1

    A very well explained tutorial sir....

  • @Misurvive
    @Misurvive 4 роки тому +1

    Thank you for very detailed explanation!!

  • @ammarlaichi8474
    @ammarlaichi8474 Рік тому +1

    Can we use inflation in laminar flow? if we can, how to calculate the first layer thikness and layer number?

  • @serdarbicer719
    @serdarbicer719 3 роки тому +3

    hello. which ansys version are you using in this video? I'm using 19.2 and I dont have most of the things you have in mesh menus

  • @soumiabaalicherif6475
    @soumiabaalicherif6475 3 роки тому +1

    Hello Mr Saud T
    would you tell me how can i extract correct Nusselt number from Fluent
    i'm working on flat plate solar collector 3D
    Thank you

  • @akramalaeldin3137
    @akramalaeldin3137 5 років тому +4

    The CFD wont recognize "Surface Heat Transfer Coefficient" in the equation
    h=areaAve(Surface Heat Transfer Coefficient)@fully_developed
    Is there any solution for this ?

    • @iqballawservice
      @iqballawservice 3 роки тому

      u didnt add data quantities in run calculation option

    • @sharmeenmoona2886
      @sharmeenmoona2886 Рік тому

      @@iqballawservice even after adding it is not showing. i ran it several times

    • @iqballawservice
      @iqballawservice Рік тому

      @@sharmeenmoona2886 madam ap nay hamain tag Kia but yeh hamari video nahi hai

    • @lordpotato3904
      @lordpotato3904 Рік тому

      hey did u find any solution for this? im getting this error too

    • @frosteven837
      @frosteven837 9 місяців тому

      [ Fluent setup>File>Preferences>Genereal>Default format for I/O>Legacy ] worked for me.

  • @WST126
    @WST126 Рік тому

    Please make their downloadable versions available!

  • @haydersakran5675
    @haydersakran5675 2 роки тому

    Do you know how to calculate the production of entropy to a rotating impeller?

  • @fero807
    @fero807 3 роки тому

    I clicked on the link you have provided, it is saying that the file is missing, make sure you have entered correct url.

  • @pavansainarasimha6741
    @pavansainarasimha6741 3 роки тому

    I am using Ansys student version 2020
    In the meshing module , I am not able to find relevance , face size and bunch of other options . Is there any way to activate these options ???
    Please let me know . It would be very helpful for my project.

  • @alizakhan5253
    @alizakhan5253 3 роки тому

    why did u change area and length in refrence values although you selected inlet. im following you as it is but i didnt changes my refrence values and the im getting 94.30 surface heat transfer cofficient instead of 1773 like yours. why u did thta so plz explain

  • @satyendraaman70
    @satyendraaman70 3 роки тому

    this tutorial is very useful for me. but sir i want know .how to put surface heat transfer coefficient term while writing expression for heat transfer coefficient...

  • @morais5029
    @morais5029 2 роки тому

    hello can you explain the processor to the sherwood number?

  • @myansis4047
    @myansis4047 4 роки тому

    thanks dude.... superbly done....

  • @samking618
    @samking618 4 роки тому

    can you explain reference values a little bit ? you put 0.5m length as it is the length of turbulent region, bur your entry length is also 0.5, so how would Fluent differentiate in this ?

  • @abdulganiyusalaudeen7640
    @abdulganiyusalaudeen7640 4 роки тому +1

    Good day.. thanks alot . Pls can you assist me on how to calculate and plot nusselt number for natural convection heat Transfer

    • @ayoube_baalla
      @ayoube_baalla 2 роки тому

      can we exchange information i have some questions please

  • @pavansainarasimha6741
    @pavansainarasimha6741 4 роки тому

    How many cells/nodes did u use ??

  • @ahmedovo3011
    @ahmedovo3011 4 роки тому

    Good job Sir. What kind or model of computer are you working on?

  • @rahulagham7591
    @rahulagham7591 3 роки тому

    Can we use this method for air also

  • @yadfaruq5294
    @yadfaruq5294 5 років тому

    thank u sir please do the same example for CFX solver

  • @samking618
    @samking618 4 роки тому

    can we use K-omerga model in this case ?

  • @hrishirajranjan7970
    @hrishirajranjan7970 3 роки тому

    Hey, if it is possible, can u simulate nusselt number for fully developed velocity and temperature profile for circular tube for uniform wall heat flux boundary condition, as it constant 4.367. thanks in advance

  • @AMITK-s1b
    @AMITK-s1b Рік тому

    google drive link not working

  • @christophergutierrez7763
    @christophergutierrez7763 3 роки тому

    why use y+=1?

  • @Ahmadnoureldin
    @Ahmadnoureldin 4 роки тому

    sorry but i saw that you substitution in Dittus equation is wrong the nusselt is 131 not 138 as u said

  • @sharmeenmoona2886
    @sharmeenmoona2886 Рік тому

    your file to download does not exist anymore.

  • @antonaveendp2896
    @antonaveendp2896 3 роки тому

    sir how to download cadd file...

  • @sfdidg
    @sfdidg Рік тому

    عاشت الايادي
    ولكن لو الشرح بصوتك افضل

  • @ShubhamMishra-ed7mb
    @ShubhamMishra-ed7mb 5 років тому +1

    Your Reynolds number is coming with unit while it's dimensionless quantity. The equation you're using for Reynolds number you have missed the unit of viscosity , change it to kg/m/s.

    • @Saudaljadir
      @Saudaljadir  5 років тому +1

      The units hasn’t missed but written in as kg/m*s which is wrong so it has been corrected in the expression at the description of the video. Thanks for noting that.

    • @ShubhamMishra-ed7mb
      @ShubhamMishra-ed7mb 5 років тому

      @@Saudaljadir ok, it's just the software got that wrong lol

    • @ShubhamMishra-ed7mb
      @ShubhamMishra-ed7mb 5 років тому

      @@Saudaljadir can you help me to contour plot the nusselts number distribution on any surface?

    • @sharmeenmoona2886
      @sharmeenmoona2886 Рік тому

      @@Saudaljadir where can i find the file to download the geometry. that link does not get us to the file to download. please suggest

  • @BinayBBora
    @BinayBBora 5 років тому

    thank you very much sir,
    can i get your mail?

  • @smailhamidatou367
    @smailhamidatou367 3 роки тому

    thanks, sir for all those, it is great ...
    when I wanna know the temperature value at in the selected point from my geometries, for example at any point on the centerline ?