  • In this video is explained about pressure switch electrical connections, setting adjustment for start and stop of water pump or motors mostly used in house or building, detailed practically explained in Urdu/Hindi.
    Please subscribe for more Technical Videos.
    #pressureswitch #electrical #plumbing
    Pressure Switch adjustment & Connection,Pump pressure switch wiring, How To Adjust a Pressure Switch
    water Pump Motor Pressure Controller Switch Connection (Urdu Hindi)
    How to install the motor pump & pressure switch w/out pressure tank
    COMO REGULAR PRESOSTATO DE BOMBA DE AGUA

КОМЕНТАРІ • 38

  • @autoliftin6291
    @autoliftin6291 Місяць тому +3

    Very good

  • @friendstrans473
    @friendstrans473 Місяць тому +1

    Excellent info ❤

  • @naeemrajput00
    @naeemrajput00 Рік тому +1

    ماشاء اللہ جزاک اللہ بہت اچھے طریقے سے آپ نے ہے سمجھایا ہے

  • @softwarehelpingtips3639
    @softwarehelpingtips3639 7 місяців тому +3

    Jinhun ne seekhna ho wo lmbi video b dekh letey han

  • @shaikhsabir3828
    @shaikhsabir3828 2 місяці тому

    2 water pump laga h 1 pressure switch laga h.no 1 pump chalta h setting presure m cut off leta h.second pump chalta h Or cut off nhi hota h.

  • @saleemahmad5496
    @saleemahmad5496 Рік тому +1

    Jajakallah khair sir

  • @AbdulKareem-fr7ud
    @AbdulKareem-fr7ud Рік тому +1

    Good teeching

  • @pravintiwari8874
    @pravintiwari8874 Рік тому +1

    Directly give pressure gauge supply to starter which will cutt off the power of starter A1 and when power exceed more then the set value ... why we are connecting it with phases...

  • @creativevideos3586
    @creativevideos3586 10 місяців тому +1

    Awesome

  • @noumansaif8487
    @noumansaif8487 Рік тому +1

    Aoa sir mera plumber ka skill verification test ha Islamabad men please ek detailed si video bna den

    • @gulflifewithasad7216
      @gulflifewithasad7216  Рік тому +1

      Walekum salam brother... Brother actually Pakistan se abh tak plumber trade test Ka feedback Kisi dost ne abh tak share nae kya .. Jese bh koe feedback milyga I will upload video.. meri Saudi Arabia mn hny wale test ki videos available hn as reference aap review KR skte ho.. par Pak mn hny wale test Saudi Arabia k test centres se boht tough hn.. aur meri videos mostly actual test feedback se bnai hti hn.. khud apni traf se bnaon to phr dost shikwa krte hn question nae ae is mn se.. I hope you understand

  • @shahwazalam1417
    @shahwazalam1417 Рік тому

    Walaikum Asalam

  • @amitkumar-yo8vt
    @amitkumar-yo8vt 5 місяців тому

    Cut in kon sa hai

  • @naeemrajput00
    @naeemrajput00 Рік тому +1

    بھائی جان یہ پریشر سوئیچ پاکستان میں مل جائے گا

  • @akilmultani4009
    @akilmultani4009 Рік тому +1

    How to connect pressure switch with float switch & single phase motor?

    • @gulflifewithasad7216
      @gulflifewithasad7216  Рік тому

      ua-cam.com/video/eRr86FD4LP4/v-deo.html
      ua-cam.com/video/26PQRjFfWng/v-deo.html
      Brother if you have this type of float switch you can connect directly..
      If you want add pressure switch you can connect same way in series with phase wire...

    • @akilmultani4009
      @akilmultani4009 Рік тому +1

      If possible make video

    • @gulflifewithasad7216
      @gulflifewithasad7216  Рік тому

      I will try brother.. actually that setup of pressure switch is not available right now I am transferred to another project but I will try my best..

    • @akilmultani4009
      @akilmultani4009 Рік тому

      Water ka pressure high ho gaya hai all bathroom, washroom and kitchen me pressure switch lagane se but tank me water nahi rahega to motor start ho jayega? Means pressure switch operate hoga?
      Uska Solution kya hai ..?
      Folat switch?

    • @gulflifewithasad7216
      @gulflifewithasad7216  Рік тому

      Tank aap Ka under ground hai ya top pe ha?
      Tank fill directly hota hai ya motor Chala K fill krna parta hai?
      Agar aap Ka tank directly fill hta hai sirf outlet side p pressure maintain krna hai to tank mn float valve lgao out let p motor with pressure switch lgao..
      Agar tank fill krne K lye bh motor Chalana hai aur pressure maintain krne K lye bh to phr mushkil Hoga q K same pressure aap K tank mn bh maintain hga Jo K dangerous hai..
      Is K lye aap ko do alag motors lgani parengi..

  • @rky186
    @rky186 Рік тому

    Ishka thread kitna tpi ka hai

  • @rinkigangwar495
    @rinkigangwar495 10 місяців тому +1

    Plz bta do sir

  • @rinkigangwar495
    @rinkigangwar495 10 місяців тому

    Kaise pta kre konsa lower limit bala screw h

  • @zubairalam1669
    @zubairalam1669 Рік тому +1

    Sir please contact