Navien NFC-175 Combi-Boiler Retrofit #4

Поділитися
Вставка
  • Опубліковано 29 гру 2024

КОМЕНТАРІ • 51

  • @dekonfrost7
    @dekonfrost7 Рік тому +4

    Honestly the best
    On youtube. Fact. .

  • @Ezzy1992
    @Ezzy1992 26 днів тому +1

    Wow ball valve on the expansion tank yes 👏🏽, ball valve on the air bleeder on top bravo 👏🏽 Jesus I haven’t seen anything like this 👏🏽👏🏽👏🏽👏🏽👏🏽👏🏽

  • @akrocuba
    @akrocuba 2 роки тому +3

    Sir, I agree with the lowest price that people take. They will either pay now....OR....pay later.
    I've been a plumber/pipefitter/boiler service tech, ect since starting doing work when I was in high school in 1983.
    I can say you have done a job WAAYYYY above and beyond!!! IT IS BEAUTIFUL!!!!! NOT ONLY BEAUTIFUL, BUT FUCTIONAL AS YOU DESCIBED IN THIOS VID!!!!
    WOW!!!! I don't see many younger guys taking prided in their work anymore. It's always seems to be just get in and get it done.
    Your are worth your weight inn gold!
    MUCH RESPECT!!!!

  • @andriisuvorov2793
    @andriisuvorov2793 Рік тому +1

    One of the cleanest jobs I ever seen!

  • @ephatla58
    @ephatla58 2 роки тому +1

    I've learned more in 20 minutes watching your video than in the last 2 days trying to find system layout instructions. Thank you.

  • @jeffreybricks2687
    @jeffreybricks2687 Рік тому

    Not only you are veryyyy very successful at boiler Installs and clean instal excellent!!! But good also at teaching THANKYOU!!😀

  • @donmccormick856
    @donmccormick856 Рік тому +1

    Your work is second to none....would have liked to see how you vented it at the roof have never seen one vented that way.

  • @ChuckKarl525
    @ChuckKarl525 2 роки тому +1

    You are proud of your work and you should be. There are many out there like you, and I wish the news media would focus on the good in humans rather than....well, lets focus on boiler installs! Be well.

  • @tonykim901
    @tonykim901 Рік тому +1

    Very clean. You work New Jersey. I’ll hire you. Great, beautiful and clean. I always say clean means you care.

    • @Ezzy1992
      @Ezzy1992 26 днів тому

      I think he is in Canada 🇨🇦

  • @TheZambie1
    @TheZambie1 2 роки тому +1

    Great videos, very helpful! Adrien from Upstate NY

  • @tylero8595
    @tylero8595 Рік тому +1

    On your thermometers for your delta t, have you thought of using tri-dicators? We use them. Pressure and temp in one. They're very easy to read too. You're boss level work as always.

  • @ramijaime2213
    @ramijaime2213 Місяць тому

    Good woork brother

  • @jeff-w
    @jeff-w Рік тому +2

    First time I've seen old pro-press fittings and as expected they're leaking. I don't understand why some people think they're the cats ass these days...its an elostomer seal! Elastomers always fail in time.

    • @GoldPlumbing
      @GoldPlumbing 3 місяці тому

      Job security.. 😢 win for the tradesman, loss for the customer.

  • @christopherwilson2606
    @christopherwilson2606 2 роки тому

    Here in the south we call em, "get the airs out-of-theres." 👍

  • @MrRickyt88
    @MrRickyt88 2 роки тому +1

    Thanks for the video that’s a masterpiece. Why should we not use propress on heating systems?

  • @longrangecarpenter5292
    @longrangecarpenter5292 2 роки тому +1

    Where did you get the isolation valves for the pump with the 1/8” not ports for the temp gauges ? I’ve searched everywhere ….

  • @petem6291
    @petem6291 2 роки тому

    James each time you do one of these boilers you raise the bar on the quality of the installation I’m getting ready to install a fire tube boiler . In my own house I have to install a low-water cut off where would you install it on a fire tube boiler .

    • @canuckmechanical6490
      @canuckmechanical6490  2 роки тому +1

      close to the boiler in the case of the Navien they have an outlet on the top for such a device but regardless its should be placed above the boiler and above all pumps return or supply side does not matter

  • @Johanfriesen
    @Johanfriesen 2 роки тому

    Thank you great video, I’m near London On, will start building our new home in Nov. where can I get a quote and can I have 10 zones for heating?

  • @dandan6018
    @dandan6018 Рік тому

    where is the Prv on the water main there?

  • @lesleyboeder1798
    @lesleyboeder1798 2 роки тому

    Very nice. Love the way you plan these systems. I just would rather see you use Bosch instead of Navien

    • @canuckmechanical6490
      @canuckmechanical6490  2 роки тому

      Not common enough in This region yet

    • @xcmskim4
      @xcmskim4 2 роки тому

      I see you've been watching Mikey Pipes? The fire tube models don't have the horrendous leaking heat exchanger design

  • @Jessedog11
    @Jessedog11 Рік тому

    why would you need a auto vent on the expansion tank bracket/manifold? and that Bypass you set up on the neutralizer condensate drain will never be seen and untreated acidic water will simply destroy the condensate pump.

  • @ephatla58
    @ephatla58 2 роки тому

    Would you be able to do a parts list in the description?

  • @leonginorivera8309
    @leonginorivera8309 10 місяців тому

    What's the reason to install that zone control. Can you would run the circulator pump with a relay box. Just question?

  • @andyyu3627
    @andyyu3627 2 роки тому +1

    Do you have a contractor in the San Francisco area?

    • @canuckmechanical6490
      @canuckmechanical6490  2 роки тому

      Unfortunately no:( but we are starting a hydroponics branch in Birmingham England next year but sadly no help there

  • @BurtGummer357
    @BurtGummer357 2 роки тому

    Great job where did you get those black pipe supports for the 3/4” copper pipes

    • @canuckmechanical6490
      @canuckmechanical6490  2 роки тому

      There are called pipe stays and they are at all our suppliers

    • @BurtGummer357
      @BurtGummer357 2 роки тому +1

      @@canuckmechanical6490 thanks so much for that info I will look into those here in Colorado keep up the great work you guys do hard to find that anymore a company and there people that take pride in there work!!

  • @longrangecarpenter5292
    @longrangecarpenter5292 2 роки тому

    What grundfos model hot water recirculation pump would you recomend for one of these combi boilers ?

  • @markhoffman
    @markhoffman 2 роки тому

    Any benefit insulating all those copper pipes?

  • @joker-if4gu
    @joker-if4gu Рік тому

    How much would you charge for a job like this?

  • @Fernando-ns3uv
    @Fernando-ns3uv 2 роки тому +1

    Who makes those black pipe clamps?

  • @omarjavierq
    @omarjavierq 2 роки тому

    How do you balance the flow in each zone?

  • @miketransamkid
    @miketransamkid 2 роки тому +1

    Wanna come to the states and redo my setup?

  • @samihabib661
    @samihabib661 2 роки тому

    Amazing install, I would have used PEX A instead of PEX B

  • @markhoffman
    @markhoffman 2 роки тому

    Spray paint the pump wire. ❤

  • @TheLogneo
    @TheLogneo 2 роки тому

    Look like Navian have a big issue with heat exchanger, and motherboard

    • @xcmskim4
      @xcmskim4 2 роки тому +2

      Fire tube models don't have the horrendous leaking heat exchanger design found in Mikey Pipes videos