Lec05 Controller of DCS System-XP243X-JX-300XP SUPCON DCS

Поділитися
Вставка
  • Опубліковано 29 гру 2024

КОМЕНТАРІ • 7

  • @DilshadAhmad-zi9iz
    @DilshadAhmad-zi9iz 7 місяців тому

    The information is given is really useful, thanks

  • @ahsanraza1781
    @ahsanraza1781 3 роки тому +1

    Good Work...

  • @mukhtarahmed9845
    @mukhtarahmed9845 3 роки тому +1

    Excellent bro.....

  • @mukhtarahmed9845
    @mukhtarahmed9845 3 роки тому +1

    Thanks dear for this very informative knowledge....... you are doing such a very good work for sharing this type technical knowledge with details and excellent graphics...

  • @sachinkapoor4107
    @sachinkapoor4107 Рік тому

    Sir, How to communicate this hardware with third party controller like Schneider, Siemens, Rockwell.

    • @malikwaqas672
      @malikwaqas672  Рік тому

      Here are the general steps you can follow:
      Understand the Modbus Communication Basics:
      Ensure you and the automation engineer are well-versed in Modbus communication. Modbus is a widely used protocol for industrial automation and can work over different physical layers like RS-232, RS-485, or Ethernet.
      Determine the Communication Medium:
      Identify the physical medium over which the communication will take place. Common options include RS-232, RS-485, or Ethernet. The choice depends on the hardware capabilities of both the Supcon JX300 XP system and the third-party controller.
      Configure Modbus Parameters:
      Define Modbus parameters such as data rate (baud rate), parity, stop bits, and data format. Both devices (Supcon JX300 XP and the third-party controller) must be configured with the same settings for successful communication.
      Select a Modbus Mode:
      Determine whether you will use Modbus RTU (Remote Terminal Unit) or Modbus TCP (Transmission Control Protocol) based on the chosen communication medium. Modbus RTU is typically used for serial connections (RS-232 or RS-485), while Modbus TCP is used over Ethernet.
      Identify Data Points:
      Decide what data points or registers you want to exchange between the Supcon JX300 XP system and the third-party controller. This includes input registers, holding registers, coils, and discrete inputs. Ensure both devices have the appropriate registers mapped or configured for data exchange.
      Write and Read Data:
      Develop or configure the automation software or script on both ends (Supcon JX300 XP and third-party controller) to write data to and read data from the designated Modbus registers.
      Testing and Troubleshooting:
      Test the communication between the Supcon JX300 XP system and the third-party controller. Monitor for errors or issues and troubleshoot as needed. Use Modbus diagnostic tools if available.