Power Factor Panel Installation in Hindi

Поділитися
Вставка
  • Опубліковано 30 вер 2024
  • This video is in Hindi language.
    We have covered the brief description of Automatic Power Factor Correction Panel, its internal parts and how to connect it with Main Panel.
    Hope this video will be useful for all electricians and persons interested to know about Power Factor Panel.
    Promoted by satya rao siddhartha

КОМЕНТАРІ • 88

  • @wajidyoutuber4555
    @wajidyoutuber4555 8 місяців тому +1

    Very good video
    Nice
    Bohat acha samjhaya ap ne

  • @JahanZeb1976
    @JahanZeb1976 4 роки тому +1

    0.99 is a very dangerous power factor and is never achieved by power factor controller.

  • @sureshmandloi8265
    @sureshmandloi8265 Рік тому

    रिएक्ट पावर मैनेजमेंट rm12 कंट्रोल वायरिंग वीडियो

  • @jagdishsant3301
    @jagdishsant3301 5 років тому +1

    c&r panel for 1.2mvar ,11kv capacitar bank panal आहे तो auto matikle चालू होतं नाही ,त्याला चालू कसे करायचे ते सांगा 9673314487

  • @sureshmandloi8265
    @sureshmandloi8265 Рік тому

    पावर फैक्टर मीटर कंट्रोल कनेक्शन कैसे करना है

  • @zeeshanahmad7070
    @zeeshanahmad7070 2 роки тому

    Reply please sir

  • @davindersingh4919
    @davindersingh4919 3 роки тому

    Pf wiring job btaiye

  • @amritsingh7340
    @amritsingh7340 3 роки тому

    Please batay

  • @zeeshanahmad7070
    @zeeshanahmad7070 2 роки тому

    Mene " selec apfc 346 " relay use ki he
    ON krne prr fault aa rha he
    ' capacitor bank is not connected '
    Iska kya meaning he ?
    Please
    Reply

    • @starautomation
      @starautomation  2 роки тому +1

      May be mcb of capacitor Bank is in off condition.
      Please ensure capacitor bank connection as per message

    • @zeeshanahmad7070
      @zeeshanahmad7070 2 роки тому

      Sir ,
      Mene 30 kw ke apfc panel ko
      5 kw ke load prr test kiya
      Power factor " 0.6 " se upar nhi jaa rha he
      aur all capacitor ON hoo gae
      What is the problem ?
      Please
      Reply

  • @amritsingh7340
    @amritsingh7340 3 роки тому

    100 KW KA LOAD H TO KITNE KVAR LAGATE H OR C.T KONCI LAGATE H

    • @starautomation
      @starautomation  3 роки тому

      For 100kw connected load, we also need the present power factor reading.
      Anyways, 100 kvar APFC panel will surely meet your requirement to achieve 0.999 PF.
      For further details, write to us at satya.starautomation@gmail.com

  • @santoskumar9215
    @santoskumar9215 6 років тому +1

    Ice painal 500 tan hindi

  • @wajidyoutuber4555
    @wajidyoutuber4555 8 місяців тому

  • @jehirulislam1029
    @jehirulislam1029 5 років тому +1

    Sir agar hamara APFC damage ho Gaya to ... manually powerfactor control hoga ki nehi

    • @starautomation
      @starautomation  5 років тому

      If load if fluctuating, then it will be difficult to control power factor

    • @shyampardeshi6373
      @shyampardeshi6373 5 років тому

      Nahi ab manuali bosibal nahi he.
      Use auto me hi chal wana he
      Kuch problem he to call kare
      7350272421

  • @Bhagwansingh-kv6df
    @Bhagwansingh-kv6df 6 років тому +1

    if power factor reduce after on of capacitors from first to next in auto mode
    what is the problem ?
    tell me

    • @starautomation
      @starautomation  6 років тому

      You should change polarity of current sensing CT. For changing polarity of CT, you need to interchange wire of CT.

    • @shyampardeshi6373
      @shyampardeshi6373 5 років тому

      Aapko Apfc dada barabar karna ho ga.
      Samjo 10kvar ka jarurat he agar 15kavar chalu huva to fir vo auto me capacitor of karega to bank set karna jaruri he. 7350272421

  • @kuldeep-eh5sn
    @kuldeep-eh5sn 6 років тому +1

    I need a panel job

  • @MuhammadAli-po2tk
    @MuhammadAli-po2tk 3 роки тому

    bus bar of panel is 1st or after main MCCB ???

  • @MuhammadAli-po2tk
    @MuhammadAli-po2tk 3 роки тому

    Busbar panel k MCCB k in p hy ya out p ???

  • @Achalkumar7895
    @Achalkumar7895 4 роки тому

    Bhai apna nub do

  • @v.krishnakumar9776
    @v.krishnakumar9776 4 роки тому

    Watistha,fograam,saying,,l,t

  • @mohd.rashid7603
    @mohd.rashid7603 4 роки тому

    Bijli ke bill me kitna effect pdta h kam krta h..

  • @ପ୍ରଦିପ୍ତକିଶୋରସ୍ବାଇଂ

    very very nice information

  • @harithapa763
    @harithapa763 6 років тому +1

    Normal gharon ke liye kitna value ki capacitor rakhne se hoga our use auto control ka kya nam hai sir please.

    • @electricgyancentre3722
      @electricgyancentre3722 6 років тому

      Sir ye single phase pe kam nhi krta he

    • @ImranKhan-ik6em
      @ImranKhan-ik6em 5 років тому +1

      Bhai ghar me capacitor use nhi hote..jo single phass capacitor hai woh fans me use hote yeh 3 phase capacitor use nhi hote ghar me

  • @bahadarsinghelectricalmuka6626
    @bahadarsinghelectricalmuka6626 6 років тому +1

    V good ji

  • @deepakparjapatielectronic6858
    @deepakparjapatielectronic6858 5 років тому

    Power factor ki drawing sir

  • @sujatabargur
    @sujatabargur 3 роки тому

    Hi, are you a panel builder or a consultant ?

    • @starautomation
      @starautomation  3 роки тому

      Our company Star Automation is Panel manufacturing company.
      satya.starautomation@gmail.com

  • @gauravbisht3870
    @gauravbisht3870 6 років тому

    Sir wiring diagram smjha sakte ho kya

  • @mdmehrajalam2358
    @mdmehrajalam2358 5 років тому

    Meine 200 kvar ka apfc panel legana hai aor trasformer hai 800 ka to mei kitney ka c.t dalu urgently

    • @starautomation
      @starautomation  5 років тому

      Sensing CT should be as per full load current in transformer supply. In your case it is 800kva.
      But if you are sure that current will not go above 400 A or 600A, then you can put current sensing CT of 400/5 or 600/5

  • @ubadesaifi783
    @ubadesaifi783 6 років тому +1

    Sir nice

  • @Sajjadk-ky7gc
    @Sajjadk-ky7gc 5 років тому

    Very good and so beautiful video Sir Ji.

  • @PankajKumar-ku4cj
    @PankajKumar-ku4cj 5 років тому

    good video

  • @shaikhsaleem532
    @shaikhsaleem532 5 років тому

    Ser 30 ampr panel ke bare me batao

  • @charlesbhatia
    @charlesbhatia 5 років тому

    Ct sense Kon se 1 st phase se 3 Rd par shift Karne se ct sense nhi Kar rhi kya problem Hai mob no 8961000001 plz tell me solutions

  • @VivekSharma-ru1dw
    @VivekSharma-ru1dw 5 років тому

    Sir Ghar ke liye powerfactor ka diagram bnaye

    • @starautomation
      @starautomation  5 років тому

      Ghar par power factor improvement cost effective nahi hai.

  • @ravinderjaiswal4341
    @ravinderjaiswal4341 5 років тому

    Bhai powerfacter tayar kase kare

    • @starautomation
      @starautomation  5 років тому

      To make Power factor Panel, you need to contact Panel manufacturing company.
      Or email me your requirement, we are also Panel manufacturer.
      satya.starautomation@gmail.com

  • @ramizbhat7883
    @ramizbhat7883 5 років тому

    bhai power factor hota kya hai ispe vdo banao

  • @ranjan1436
    @ranjan1436 4 роки тому

    how does Cts locate pf??

    • @starautomation
      @starautomation  4 роки тому +1

      CT is used to sense the current flowing in conductor or wire.
      Voltage and current input in the controller makes it calculate all the parameters

  • @charlesbhatia
    @charlesbhatia 5 років тому

    Power factor.93 work Kar rha hai.99 kaise maintain kare

    • @shyampardeshi6373
      @shyampardeshi6373 5 років тому

      Aapne kitane bank ka panel banvaya he.Aapka lod kitana he vosab dekhana padega tao hojayega.99pf nahi pura 1pf aana chaiye
      Mera numbar he
      7350272421

  • @mchiragpatel
    @mchiragpatel 5 років тому

    Sir can you please tell me the benefits of Power Factor in Control Panel? I understand the fittings in video. But I want to know the main benefits of i for LT connection.

    • @shyampardeshi6373
      @shyampardeshi6373 5 років тому +1

      Power factor panels se currant kam hota he .
      Or maharashtrame 27hp se upar wale consumer ko 3.5 incentive milta he

    • @JahanZeb1976
      @JahanZeb1976 4 роки тому

      Current reduction in the system.

  • @toptenintheworld7293
    @toptenintheworld7293 5 років тому

    30 hp
    20 hp
    20 hp
    4pc 3hp
    100ka transformer h in SB Ka power factor panel banana h to sir Kitney kvr Ka bnega or transfarmer Ka capacitor panel me hi lgey ga
    Kitney Kitney kvr key capacitor use hongey line wies

  • @jehirulislam1029
    @jehirulislam1029 5 років тому

    Sir Energy meter me p.f. mode par kya symbol ana sahia .... capacitor ya Inductor ??? jab pf Ok hota ha ???

    • @starautomation
      @starautomation  5 років тому

      It should display inductive load at 0.999

    • @shyampardeshi6373
      @shyampardeshi6373 5 років тому

      Pf ok he to 0.999 ya to pf 1 hona chahiye kuch prefer he to call kare
      7350272421

  • @jehirulislam1029
    @jehirulislam1029 5 років тому

    Mera ek panel ha ...65 kvar Ka...jab capacitor ON karta hu to pf Minus me sala jata ha....

    • @starautomation
      @starautomation  5 років тому

      Try to change polarity of current sensing CT by interchanging connection of CT wires

    • @shyampardeshi6373
      @shyampardeshi6373 5 років тому

      Manuali capacitor lod se jyada chalu hogato pf mainus ne hi jayega

    • @shyampardeshi6373
      @shyampardeshi6373 5 років тому

      Kuch taklif he to call kare

  • @mdmehrajalam2358
    @mdmehrajalam2358 5 років тому

    Jaise transformer hai 400 aor 200 to iska ct kaise nikala h

  • @raghvendrachanpuriya7680
    @raghvendrachanpuriya7680 5 років тому

    Sir , in which city your training center located? I am interested for training